6
INSTALLATION AND OPERATING INSTRUCTIONS
D. OPERATION INSTRUCTIONS
1. Plug unit into power socket, unit will beep twice.
2. Press POWER button
to turn unit on. The dry air outlet
air deflector will open and the blue backlight will illuminate
and turn off after 15 seconds. The LCD display will show
the working mode, status of unit, ambient humidity and
temperature.
Note:
The dehumidification setting is automatically set on continuous
and default fan speed is set at High (H).
Note:
The dry air outlet air deflector will close when unit is turned
off. Press power button to turn unit off.
3. MODE button sets up Continuous/Automatic dehumidifying
modes and Fan speed.
4. SETTING button confirms the running fan speed or Continuous/
Automatic dehumidifying ratio.
5. To set automatic dehumidifying relative humidity (RH) ratio,
press MODE button until LCD display lights up on the icon
.
Press SETTING button to select relative humidity (RH) ratio in 5%
increments between 40% - 80%, and then press MODE to set
selection, or three seconds after pressing SETTING the desired
humidity ratio is set and the indicator light will stop illuminating.
Note:
When setting unit on automatic dehumidification, the
continuous dehumidifying mode
will be cancelled.
Note:
When the ambient relative humidity is 1% lower than the
selected relative humidity ratio percentage (RH%), the unit
compressor will switch off and fan speed will operate at a Low (L).
Note:
When the ambient relative humidity is 5% higher than the
selected relative humidity ratio percentage (RH%), the unit will
switch on and unit will operate at the selected setting.
Note:
The unit will continuously run, regardless of the ambient
relative humidity, when continuous dehumidification mode
is set.
6. To set fan speed, press MODE button until LCD display lights
up on the fan icon
. Press SETTING button to select
between high (H) and low (L) fan speed, and then press MODE
to set selection, or three seconds after pressing SETTING
the fan speed is set. When fan speed is set the fan icon
will rotate.
Note:
When the temperature sensor detects the ambient humidity
is lower than selected setting, fan will work at a low (L) speed.
Note:
When the temperature sensor detects the ambient room
temperature to be higher or equal to 32°C, the unit fan speed will
automatically switch to operate at high (H).
7. To set continuous dehumidification, press MODE button until
LCD displays the continuous dehumidification icon
and then
press SETTING to set continuous dehumidification mode.