background image

manual

V1

.

0

 

DECEMBER

 

2016

WWW

.

CLF

-

LIGHTING

.

COM

YARA

YARA

Содержание YARA

Страница 1: ...manual V1 0 DECEMBER 2016 WWW CLF LIGHTING COM YARA Y A R A ...

Страница 2: ...he fixture to a flat surface 7 Setup 8 Control panel and menu navigation 8 DMX address setting 8 Control Mode 8 Static Color options 9 Auto Show 10 Master Slave 10 Personality 11 Dimmer Speed 11 Key Lock 11 Calibration 11 Refresh rate 11 LCD brightness 11 Information 11 Software type 11 Usage time 11 Temperature 11 UID 11 Factory reset 11 DMX protocols 12 Onboard control menus 15 Blow out Diagram ...

Страница 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 0 YARA 106 260 290 Φ203 180 ...

Страница 4: ...tion Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices Power input and through out cables must be rated 20A minimum have three conductors 1 5 mm 16 AWG minimum conductor size and an outer cable diameter of 5 15 mm Cables must be hard usage type SJT or equivalent and heat resistant...

Страница 5: ...e of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irritation At distances of 3 meters and above light output is harmless to the naked eye provided that the eye s natural aversion response is not overcome Do not look at LEDs with magnifiers telescopes binoculars or similar optical instruments that may co...

Страница 6: ...fety cable attachment point LCD Display 5P DMX input 5P DMX output AC mains power output AC mains power input G Clamp with Quicklock 875760 Optional Omega bracket with Quicklock 520114 Optional 3 P DMX input optional CLF 13 453 3P DMX output optional CLF 13 454 ...

Страница 7: ...eaker and ground fault earth fault protection Warning Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove live connectors to apply or cut power as this may cause arcingat the terminals that will damage the connectors Importa...

Страница 8: ...ted daisy chain using power input and through out connectors Relaying power to other devices Warning Do not connect more than ten fixtures in total to AC mains power in one interconnected chain Power can be relayed to another device via the PowerCON TRUE 1 output socket If you daisy chain the fixtures in a chain so that they all draw AC mains power via the first fixture certain points must be resp...

Страница 9: ...t 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or cooling may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment point see Fixture overview on page 4 if...

Страница 10: ...ddress setting The DMX address also known as the start channel is the first channel used to receive instructions from the controller For independent control each fixture must be assigned its to a separate channel The DMX address can be configured by using the DMX ADDRESS menu in the control panel For setting the DMX address press ENTER before you can change the adddres In order to check if there i...

Страница 11: ...GB Green Blue RGW Red Green White B Blue RGB Red Green Blue RBW Red Blue White W White RW Red White GBW Green Blue White RG Red Green GW Green White RGBW Red Green Blue White Red 000 255 Dimmer Red Green 000 255 Dimmer Green Blue 000 255 Dimmer Blue White 000 255 Dimmer White 2000K 255 Red 135 Green 0 Blue 35 White 3000K 255 Red 165 Green 0 Blue 135 White 4000K 255 Red 180 Green 28 Blue 220 White ...

Страница 12: ...to slave function when no DMX signal is offered 1 Auto 1 Auto program 1 11 Program 1 pre program 1 2 Auto 2 Auto program 2 12 Program 2 pre program 2 3 Auto 3 Auto program 3 13 Program 3 pre program 3 4 Auto 4 Auto program 4 14 Program 4 pre program 4 5 Auto 5 Auto program 5 15 Program 5 pre program 5 6 Auto 6 Auto program 6 16 Program 6 pre program 6 7 Auto 7 Auto program 7 17 Program 7 pre progr...

Страница 13: ...n MANUAL calibration mode ON OFF Refresh rate Controls the Flicker frequency of the fixture 600 1200 2400 4800 LCD brightness Set the LCD display brightness 1 10 Software type Shows software version Vx x Usage time Use of time and use time reset password Temperature LED board current temperature UID Shows the unique ID for the RDM protocoll 0x02E20002xxxx Information Factory reset Resets the fixtu...

Страница 14: ...00 255 0 100 4 White 000 255 0 100 6 CH Function Value Setting Remark 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 White 000 255 0 100 6 Shutter 000 024 025 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 144 145 149 150 164 165 169 170 184 185 189 190 204 205 209 210 224 225 229 230 244 245 255 Shutter open Strobe 1 fast slow Shutter open...

Страница 15: ...4 225 229 230 244 245 255 Shutter open Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast slow Shutter open Strobe 6 random closing pulse fast slow Shutter open Strobe 7 burst pulse fast slow Shutter open Strobe 8 random burst pulse fast slow Shu...

Страница 16: ...ave fast slow Shutter open Strobe 10 burst fast slow Shutter open 7 CCT 000 009 010 255 No function 8000K 2000K 8 Color wheel 000 004 005 255 No Function Color wheel rotation effect 9 Auto program 000 009 010 019 020 029 100 109 110 119 120 129 200 255 No function Auto program 1 Auto program 2 Auto program 10 program 10 AUTO 1 10 cycle Custom program 1 Custom program 2 Custom 10 Speed 000 1 255 No...

Страница 17: ...bration No Calibration Red 0 255 Manual Green 0 255 Blue 0 255 Default NO CALIBRATION Refresh rate 600 1200 2400 4800 Default 600 LCD brightness Level 1 10 4 STATIC COLOR Fixed color R G RB GW GBW B GB BW RGBW W RGB RGW RG RW RBW Default RGBW White presets 2000K 3000K 4000K 5000K 6000K 7000K 8000 Default 6000K Manual color Red 0 255 Green 0 255 Blue 0 255 White 0 255 Default Red 255 Green 255 Blue...

Страница 18: ...ver CLF 14 017 9 Power supply CLF 14 015 10 Power supply support bracket CLF 14 007 11 Case body CLF 14 001 12 Display board CLF 14 034 13 Display sticker CLF 14 020 14 Acrylic display support CLF 14 012 15 PowerCON TRUE1 input socket CLF 14 027 16 PowerCON TRUE1 output socket CLF 14 028 17 DMX 5 pin male chassis part waterproof CLF 14 032 18 DMX 5 pin female chassis part waterproof CLF 14 031 19 ...

Страница 19: ...ials 100 mm from fixture Minimum distance to illuminated surfaces 200 mm from fixture Connections AC power input PowerCON TRUE 1 input socket AC power output PowerCON TRUE 1 output socket DMX data in out 5 pin locking XLR 3 pin optional with CLF 13 453 CLF 13 454 Electrical AC power 100 240 V nominal 50 60 Hz Maximum total power consumption 105 W Power supply unit Auto ranging electronic switch mo...

Страница 20: ... possible but keep in mind that it can bring damage to aging materials and affect the coated surface i e stainless steel Rubber sealings will be negatively affected after long term UV exposure and should be checked by qualified service technicians over time Tighten screws too hard will also affect the IP rating solid object Moisture 1 2 3 4 5 6 7 8 IP Ingress Protection 6 5 Protected against a sol...

Страница 21: ...YARA WWW CLF LIGHTING COM CLFLIGHTING ...