background image

WWW

.

CLF

-

LIGHTING

.

COM

12

.

0

Software type

Shows

 

software

 

version

 (

Vx

.

x

)

Usage time

Use of time and use time reset (password)

Temperature

LED

 

board

 

current

 

temperature

UID

Shows the unique ID for the RDM protocoll. <0x02E20002xxxx>

Information

Factory

 

reset

Resets

 

the

 

fixture

 

to

 

its

 

factory

 

default

 

settings

.

Please reboot power before reset takes effect.

DIMMER

 

MODE

 

provides

 

f

ive

 

dimming

 

options

 (

see

 

picture

 

below):

O

ut

pu

t

O

ut

pu

t

O

ut

pu

t

O

ut

pu

t

DMX %

LINEAR

DMX %

SQUARE LAW 

DMX %

INVERSE SQUARE LAW

DMX %

S-CURVE

O

ut

pu

t

DMX % Up                     DMX % Down

SPECIAL

l

LINEAR 

– the increase in light intensity appears to be linear as DMX value is increased.

l

SQUARE LAW 

– light intensity control is finer at low levels and coarser at high levels.

l

INV Square law 

– light intensity control is coarser at low levels and finer at high levels.

l

S-CURVE 

– light intensity control is finer at low levels and high levels and coarser at medium levels. 

l

Special 

– the light intensity was linear increase with DMX value , and light intensity control is finer at low level 

                                   

with DMX values decrease , the dimmer speed will also has effect on it 

Whichever

 

DIMMER CURVE 

option

 

you

 

select

,

 

you

 

can

 

choose

 

between

 

NORMAL 

or

 

SMOOTH 1 / 2 / 3 / 4 

dimming 

settings

:

l

NORMAL 

is the default setting. It gives a virtually instantaneous reaction when you dim from one intensity to 

another

but

 

dimming

 

slowly

 

from

 

one

 

intensity

 

to

 

another

 

may

 

appear

 

slightly

 

uneven

.

l

The 

MOOTH 1 / 2 / 3 / 4 

setting gives smoother dimming during slow changes in intensity, but it limits the speed 

of dimming

 

changes

 

slightly

This

 

makes

 

it

 

ideal

 

for

 

slow

smooth

 

dimming

but

 

a

 

short

 

time

-

lag

 

may

 

be 

noticeable

 

if

 

you

 

try

 

to

 

dim

 

quickly

 

from

 

one

 

intensity

 

to

 

another

.

Содержание HERA

Страница 1: ...manual V1 0 March 2018 WWW CLF LIGHTING COM HERA H E R A ...

Страница 2: ...ixture to a flat surface 7 Setup 8 Control panel and menu navigation 8 DMX address setting 8 Control Mode 9 Static Color options 10 Auto Show 11 Master Slave 11 Personality 11 Dimmer speed 11 Dimmer curve 11 Key Lock 11 W DMX 11 Calibration 11 Refresh rate 11 LCD brightness 11 DMX HOLD 11 Dimmer mode 12 Information 12 Software type 12 Usage time 12 Temperature 12 UID 12 Factory reset 12 DMX protoc...

Страница 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 0 hera 106 260 290 Φ203 180 ...

Страница 4: ...d observe all warnings in this manual and printed on the fixture If you have questions about how to operate the fixture safely please contact your supplier PROTECTION FROM ELECTRIC SHOCK l Disconnect the fixture from AC power before removing or installing any cover or part and when not in use l Always ground earth the fixture electrically l Use only a source of AC power that complies with local bu...

Страница 5: ...the optional CLF Hera filters l Do not modify the fixture in any way not described in this manual l Do not use fixture on a dimmer PROTECTION FROM INJURY l Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irrita...

Страница 6: ... cable attachment point LCD Display 5P DMX input 5P DMX output AC mains power throughput AC mains power input G Clamp with Quicklock 875760 Optional Omega bracket with Quicklock 520114 Optional 3P DMX input optional CLF 13 453 3P DMX output optional CLF 13 454 HERA ...

Страница 7: ...or circuit breaker and ground fault earth fault protection Warning Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove live connectors to apply or cut power as this PowerCON TRUE 1 may cause arcing at the terminals that will...

Страница 8: ...ust be used to connect the first fixture to AC mains power connectors must be used to draw AC mains power from the fixtures power throughput PowerCON TRUE 1 sockets and yellow connectors must be used to supply power at the fixture s power input PowerCON TRUE 1 sockets No matter what the AC mains power voltage is do not connect more than ten the fixture in total including the first fixture to AC ma...

Страница 9: ...face can support at least 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or air vents in the base may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment p...

Страница 10: ...s can be configured by using the DMX ADDRESS menu in the control panel For setting the DMX address press ENTER before you can change the address The main screen will show a dot and the backlight will be switched off when a DMX signal is detected The fixture is fully RDM ready So when you are using a RDM ready console you can address the unit and read out its complete status For RDM functions pleas...

Страница 11: ...ty WWW CLF LIGHTING COM 9 0 Control mode DMX control mode is selected in the CONTROL MODE menu The fixture has 9 DMX control modes 4ch 5ch 6ch 7ch 8ch 11ch 13ch Dimmer RGBW A UV Strobe CCT Macro color Effect Dimmer Auto speed Function set ...

Страница 12: ...lor Mix your own color with each RGBWAP value seperately R Red RB Red Blue BW Red White G Green GB Green Blue RGW Red Green White B Blue RGB Red Green Blue RBW Red Blue White W White RW Red White GBW Green Blue White RG Red Green GW Green White RGBW Red Green Blue White Red 000 255 Dimmer Red Green 000 255 Dimmer Green Blue 000 255 Dimmer Blue White 000 255 Dimmer White Amber 000 255 Dimmer Amber ...

Страница 13: ...gram 6 7 Auto 7 Auto program 7 17 Program 7 pre program 7 8 Auto 8 Auto program 8 18 Program 8 pre program 8 9 Auto 9 Auto program 9 19 Program 9 pre program 9 10 Auto 10 Auto 1 10 cycle program 20 Program 10 pre program 10 Here you can set all functions for the fixture personality Dimmer Speed Normal Smooth 1 Smooth 2 Smooth 3 Smooth 4 Dimmer curve linear Square law INV Square law S Curve Special...

Страница 14: ...tensity control is coarser at low levels and finer at high levels l S CURVE light intensity control is finer at low levels and high levels and coarser at medium levels l Special the light intensity was linear increase with DMX value and light intensity control is finer at low level with DMX values decrease the dimmer speed will also has effect on it Whichever DIMMER CURVE option you select you can...

Страница 15: ...2 Saturation 000 255 0 100 3 Value 000 255 0 100 HSI Function Value Setting Remark 1 Hue 000 255 0 100 2 Saturation 000 255 0 100 3 Intensity 000 255 0 100 4 CH Function Value Setting Remark 1 Red 000 255 0 100 2 Green 000 255 0 100 3 Blue 000 255 0 100 4 White 000 255 0 100 5 CH Function Value Setting Remark 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 W...

Страница 16: ...en Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast slow Shutter open Strobe 6 random closing pulse fast slow Shutter open Strobe 7 burst pulse fast slow Shutter open Strobe 8 random burst pulse fast slow Shutter open Strobe 9 sine wave fast sl...

Страница 17: ...low Shutter open 7 CCT 000 009 010 255 No function 10000K 2500K 8 Color wheel 000 009 010 255 No Function Color wheel rotation effect 9 Auto program 000 009 010 019 020 029 100 109 110 119 120 129 200 255 No function Auto program 1 Auto program 2 Auto program 10 AUTO 1 10 cycle Custom program 1 Custom program 2 Custom program 10 10 Speed 000 1 255 No function AUTO Speed or Dimmer Speed 11 Fixture ...

Страница 18: ...obe 10 burst fast slow Shutter open 9 CCT 000 009 010 255 No function 10000K 2500K 10 Color wheel 000 004 005 255 No Function Color wheel rotation effect 11 Auto program 000 009 010 019 020 029 100 109 110 119 120 129 200 255 No function Auto program 1 Auto program 2 Auto program 10 AUTO 1 10 cycle Custom program 1 Custom program 2 Custom program 10 12 Speed 000 1 255 No function AUTO Speed or Dim...

Страница 19: ... Macro color 9 Effect 10 Speed 11 Function set 13CH 1 Dimmer 2 Red 3 Green 4 Blue 5 White 6 Amber 7 UV 8 Strobe 9 CCT 10 Macro color 11 Effect 12 Speed 13 Function set HSV 1 Hue 2 Saturation 3 Value HSI 1 Hue 2 Saturation 3 Intensity 3 PERSONALITY Dimmer Speed Normal Default Normal Smooth 1 Smooth 2 Smooth 3 Smooth 4 Dimmer curve linear Default linear Square law INV Square law S Curve Special Key ...

Страница 20: ...AUV CCT 2500K 3000K 4000K 5000K 6000K 7000K 8000 9000K 10000K Default 6000K Manual color Dimmer 0 255 Red 0 255 Green 0 255 Blue 0 255 White 0 255 Amber 0 255 UV 0 255 Strobe 0 20 Default Dimmer 255 Red 255 Green 255 Blue 255 White 255 Amber 255 UV 255 Strobe 0 5 AUTO AUTO 1 10 Speed 0 20 Default AUTO 1 Programe 1 10 6 EDITOR Programe 01 10 Scene 01 30 Red 0 255 Green 0 255 Blue 0 255 White 0 255 ...

Страница 21: ...r CLF 14 017 9 Power supply CLF 14 015 10 Power supply support bracket CLF 14 007 11 Case body CLF 14 001 12 Display board CLF 17 005 13 Display sticker CLF 17 004 14 Acrylic display support CLF 14 012 15 PowerCON TRUE1 input socket CLF 14 027 16 PowerCON TRUE1 output socket CLF 14 028 17 DMX 5 pin male chassis part waterproof CLF 14 032 18 DMX 5 pin female chassis part waterproof CLF 14 031 19 Va...

Страница 22: ... materials 100 mm from fixture Minimum distance to illuminated surfaces 200 mm from fixture Connections AC power input PowerCON TRUE 1 input socket AC power throughput PowerCON TRUE 1 output socket DMX data in out 5 pin locking XLR 3 pin optional with CLF 13 453 CLF 13 454 Electrical AC power 100 240 V nominal 50 60 Hz Maximum total power consumption 105 W Power supply unit Auto ranging electronic...

Страница 23: ... possible but keep in mind that it can bring damage to aging materials and affect the coated surface i e stainless steel Rubber sealings will be negatively affected after long term UV exposure and should be checked by qualified service technicians over time Tighten screws too hard will also affect the IP rating solid object Moisture 1 2 3 4 5 6 7 8 IP Ingress Protection 6 5 Protected against a sol...

Страница 24: ...WWW CLF LIGHTING COM 22 0 NOTE ...

Страница 25: ...Hera WWW CLF LIGHTING COM CLFLIGHTING ...

Отзывы: