www.cleveracoustics.co.uk
ZM4 4 Zone Mixer
User Manual
9
Operating instructions
MIC priority:
During normal operation the ZM4 features priority for MIC1 over the other microphone and line inputs.
For certain applications, the installation engineer may need to defeat the MIC1 priority function. In order
to do this, the product must be fully disconnected from any AC or DC power sources, and disconnected
from all inputs/outputs.
Remove the 12 screws from the outer casing as per the diagram below and keep in a safe location.
Remove the upper casing and place to one side. Locate the PCB towards the rear of the unit as pictured
below. Carefully move the jumper from the
"ON"
position to the
"OFF"
position. Refit the outer casing,
taking care to avoid damaging the unit. Refit all of the screws to fully secure the outer casing.
Top of Mixer
Rear of Mixer
Side 1 of Mixer
Side 2 of Mixer