Panel & connection identification

ZM4 4 Zone Mixer

PHANTOM

LINE

MIC

DC 24V       450mA

+

LINE OUT - BAL/UNBAL

ZONE 1

G

+

LINE OUT - BAL/UNBAL

ZONE 2

G

+

LINE OUT - BAL/UNBAL

ZONE 3

G

+

LINE OUT - BAL/UNBAL

ZONE 4

G

+

VOLUME

Z1

Z3

Z2

Z4

CH 1

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

VOLUME

Z1

Z3

Z2

Z4

CH 2

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

VOLUME

Z1

Z3

Z2

Z4

CH 3

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

VOLUME

Z1

Z3

Z2

Z4

CH 4

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

VOLUME

Z1

Z3

Z2

Z4

CH 5

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

ON

OFF

POWER

VOLUME

ZONE 3

MONITOR

0

1

2

3

4

5

6

7

8

9

10

ZONE 1

ZONE 2

ZONE 4

VOLUME

MONITOR

0

1

2

3

4

5

6

7

8

9

10

VOLUME

MONITOR

0

1

2

3

4

5

6

7

8

9

10

VOLUME

MONITOR

0

1

2

3

4

5

6

7

8

9

10

0

10

PHONE

PHONE

VOLUME

MONITOR

VOLUME

0

10

 

MONITOR

LINE OUTPUT

G

+

MONITOR
1W      8Ω

PRIORITY

+

TEL PAGING

COM

GND

HOT

POWER INPUT:

110-240V~50/60Hz

110-120V~60Hz - FUSE: T6.3A 250V

220-240V~50/60Hz - FUSE: T3.15A 250V

110-120V~

220-240V~

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

www.cleveracoustics.co.uk

TEL

VOLUME

ZONE

CH4

CH2

CH1

CH3

L

R

CH5
LINE

PHANTOM

LINE

MIC

PHANTOM

LINE

MIC

PHANTOM

LINE

MIC

SERIAL NUMBER

POWER CONSUMPTION (max.): 22W

LF

HF

GAIN

LF

HF

GAIN

LF

HF

GAIN

LF

HF

GAIN

LF

HF

GAIN

5

1

2

3

4

7

9

11

13

6

8

8

10

12

ZM4 4 Zone Mixer

PHANTOM

LINE

MIC

DC 24V       450mA

+

LINE OUT - BAL/UNBAL

ZONE 1

G

+

LINE OUT - BAL/UNBAL

ZONE 2

G

+

LINE OUT - BAL/UNBAL

ZONE 3

G

+

LINE OUT - BAL/UNBAL

ZONE 4

G

+

VOLUME

Z1

Z3

Z2

Z4

CH 1

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

VOLUME

Z1

Z3

Z2

Z4

CH 2

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

VOLUME

Z1

Z3

Z2

Z4

CH 3

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

VOLUME

Z1

Z3

Z2

Z4

CH 4

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

VOLUME

Z1

Z3

Z2

Z4

CH 5

0

1

2

3

4

5

6

7

8

9

10

-10

+10

-10

+10

-10

+10

ON

OFF

POWER

VOLUME

ZONE 3

MONITOR

0

1

2

3

4

5

6

7

8

9

10

ZONE 1

ZONE 2

ZONE 4

VOLUME

MONITOR

0

1

2

3

4

5

6

7

8

9

10

VOLUME

MONITOR

0

1

2

3

4

5

6

7

8

9

10

VOLUME

MONITOR

0

1

2

3

4

5

6

7

8

9

10

0

10

PHONE

PHONE

VOLUME

MONITOR

VOLUME

0

10

 

MONITOR

LINE OUTPUT

G

+

MONITOR
1W      8Ω

PRIORITY

+

TEL PAGING

COM

GND

HOT

POWER INPUT:

110-240V~50/60Hz

110-120V~60Hz - FUSE: T6.3A 250V

220-240V~50/60Hz - FUSE: T3.15A 250V

110-120V~

220-240V~

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN. NO USER 

SERVICABLE PARTS INSIDE

www.cleveracoustics.co.uk

TEL

VOLUME

ZONE

CH4

CH2

CH1

CH3

L

R

CH5
LINE

PHANTOM

LINE

MIC

PHANTOM

LINE

MIC

PHANTOM

LINE

MIC

SERIAL NUMBER

POWER CONSUMPTION (max.): 22W

LF

HF

GAIN

LF

HF

GAIN

LF

HF

GAIN

LF

HF

GAIN

LF

HF

GAIN

15 14

17

23

24

25

26

16

18 19 20 21

22

24

25

01 - Gain control
02 - HF level control
03 - LF level control
04 - Input channel level control
05 - Zone selection switches
06 - Headphone level control
07 - Headphone output
08 - LED VU output meter
09 - Monitor level control
10 - Zone output level control

11 - Monitor output selector
12 - Power LED
13 - Power switch
14 - AC mains power input
15 - AC mains fuse
16 - AC voltage selector
17 - 24V DC power input
18 - Monitor (MIX) line output
19 - Monitor loudspeaker output  

    (1W 8Ω)

20 - Priority control terminals
21 - Telephone/paging input (TEL)
22 - Telephone/paging input  

    zone selection & volume control

23 - Stereo LINE inputs
24 - Mono MIC/LINE inputs
25 - Input sensitivity and phantom  

    power control

26 - Balanced line level zone outputs

Содержание ZM4

Страница 1: ...2 3 4 5 6 7 8 9 10 ZONE 1 ZONE 2 ZONE 4 VOLUME MONITOR 0 1 2 3 4 5 6 7 8 9 10 VOLUME MONITOR 0 1 2 3 4 5 6 7 8 9 10 VOLUME MONITOR 0 1 2 3 4 5 6 7 8 9 10 0 10 PHONE PHONE VOLUME MONITOR VOLUME 0 10 MO...

Страница 2: ...abels from the unit Do not open the equipment and do not modify the unit Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors...

Страница 3: ...OLUME Z1 Z3 Z2 Z4 CH 3 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 4 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 5 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 ON OFF...

Страница 4: ...10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 2 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 3 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 4 0 1 2 3 4 5 6 7 8 9 10 10 1...

Страница 5: ...he zone mixers input channels Turn the level control anti clockwise to the lowest setting or turn clockwise to adjust to the highest setting Adjustments should be made gradually to avoid any sudden ch...

Страница 6: ...h On Off control for the zone amplifier Note The on off power switch does not have any control over the 24V DC power input 14 AC mains power input Before connecting the amplifier to the local mains vo...

Страница 7: ...amplifier 22 Telephone paging input zone selection volume control The TEL input features zone control and input volume control To route the TEL signal to a desired output zone move the corresponding D...

Страница 8: ...tion and all tone equaliser controls to the mid zero point Deselect all monitor and zone selection controls Switch on the zone mixer and any audio sources MP3 players CD players Microphones etc before...

Страница 9: ...disconnected from any AC or DC power sources and disconnected from all inputs outputs Remove the 12 screws from the outer casing as per the diagram below and keep in a safe location Remove the upper...

Страница 10: ...r PA Amplifier PA Amplifier Horn speaker Horn speaker Column speaker Column speaker Speaker Speaker Recorder CD Player AM FM Tuner 24V Recorder Desktop Mic Microphone Speaker Amplifier Contact Voice P...

Страница 11: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of materi...

Страница 12: ...www cleveracoustics co uk ZM4 4 Zone Mixer User Manual 12...

Отзывы: