Operating instructions

25. Audio BUS RJ45 Input Volume Control

To adjust the input signal level on the Audio BUS, turn the level control anti clockwise to the lowest 
setting, or turn clockwise to adjust to the highest setting.

Power On/Off Procedure

Prior to making any connection to the mains power or audio inputs/outputs, turn all level controls 
counter clockwise to the “min” position and all tone (equaliser) controls to the mid (zero) point.  
Switch on the zone mixer and any audio sources (MP3 players, CD players, Microphones etc) before 
powering the systems amplifier ON. The last product to be switched on should be the power/slave 
amplifiers to prevent any unwanted noise or potential damage to speakers or amplifiers. If you wish 
to power off the system, turn the amplifier’s master volume control counter clockwise to the “min” 
position before switching the amplifier OFF before any audio sources are switched off. By following this 
procedure it will prevent acoustic shocks to the speakers or potential damage to system components. 
After connecting all audio sources and powering on the system, adjust the level of each audio input, 
select the zone routing in order to achieve the desired “mix” for each zone. Care should be taken 
to when adjusting microphone input volumes and the master volume, adjust both of these in small 
increment’s to avoid feedback (howl around). The goal is to achieve a clear balance between music  
and voice ensuring announcements can be clearly heard.
 

Internal Jumper System Configuration:

Cascading Multiple Units:

Via the AUDIO BUS IN and OUT connectors 16 units can be combined to one system  
so that you have available max. 64 MIC/LINE and 48 AUX inputs. 

The audio signal will be fed to the next unit via the “AUDIO BUS OUT“ output.
Via the mute link connector the different mute signals are passed to the other units. This allows  
i.e. that a VOX priority of MIC1 not only mutes the inputs of the particular unit but also the inputs  
of the other units.
By internal jumpers you can select  to what external mute signals a particular unit should react.  
You find more details in chapter 3.5.
By shortening the mute link connector all inputs of all connected units will be muted.

Содержание ZM 84

Страница 1: ...SS 15 15 TREBLE 15 15 BASS 15 15 TREBLE 15 15 BASS 15 15 TREBLE 15 15 dB P OUTPUT 4 OUTPUT 4 OUTPUT 3 OUTPUT 2 OUTPUT 1 AUDIO BUS OUT AUX 3 AUX 2 AUX 1 AUDIO BUS IN OUTPUT 3 10 EMR MUTE LINK GAIN MIX...

Страница 2: ...nd all mains voltage connections with particular caution Never remove warning or informative labels from the unit Do not open the equipment and do not modify the unit Do not switch the equipment on an...

Страница 3: ...ve segment LED output level indicators Mute function via contact closure for muting all channels Internal switch mode multi voltage power supply 1U 19 rackmount chassis with brushed aluminium front pa...

Страница 4: ...UTE LINK GAIN MIX IN POWER INPUT 100 240V 50 60Hz FUSE T1A 250V POWER CONSUMPTION max 20W MIC LINE 4 PHANTOM 48V PAD 30dB GAIN MIX IN dB 10 MIC LINE 3 PHANTOM 48V PAD 30dB GAIN MIX IN dB 10 MIC LINE 2...

Страница 5: ...te VOX Priority Adjustment Microphone input 2 features automatic priority VOX over MIC LINE channels 3 4 plus AUX channels 1 4 To adjust the sensitivity turn the potentiometer anti clockwise for the c...

Страница 6: ...Each of the MIC Line volumes are adjustable Turn the level control anti clockwise to the lowest setting or turn clockwise to adjust to the highest setting 13 AUX 1 4 Signal Overload LED Indicators Eac...

Страница 7: ...the level control anti clockwise to the lowest setting or turn clockwise to adjust to the highest setting 48V Phantom Power The ZM 84 features switchable phantom power on each of the MIC 1 4 channels...

Страница 8: ...shocks to the speakers or potential damage to system components After connecting all audio sources and powering on the system adjust the level of each audio input select the zone routing in order to...

Страница 9: ...inputs C Jumper for low cut On Off of Mic inputs D Jumper for input routing E Jumper for MUTE LINK mode Important Warning The internal jumper system should only be adjusted by a qualified engineer wi...

Страница 10: ...e jumpers Factory setting is jumper J11 2 J11 3 in OFF and the jumper J11 0 in ON position Signal Routing Every audio input can be individually assigned to one of the internal busses Factory setting i...

Страница 11: ...www cleveracoustics co uk ZM 84 Audio Mixer User Manual 11 Block Overview Routing Block Diagrams...

Страница 12: ...www cleveracoustics co uk ZM 84 Audio Mixer User Manual 12 MIC 1 Block Diagram MIC 3 Block Diagram MIC 2 Block Diagram MIC 4 Block Diagram Block Diagrams...

Страница 13: ...www cleveracoustics co uk ZM 84 Audio Mixer User Manual 13 AUX 1 Block Diagram AUX 3 Block Diagram AUX 2 Block Diagram AUX 4 Block Diagram Block Diagrams...

Страница 14: ...www cleveracoustics co uk ZM 84 Audio Mixer User Manual 14 Block Diagrams Block Diagram Pin Configuration...

Страница 15: ...www cleveracoustics co uk ZM 84 Audio Mixer User Manual 15 Block Diagrams Typical panel connections Typical Panel Connections EMER Block Diagram INSERT Block Diagram...

Страница 16: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of materi...

Отзывы: