Installation

Rack Installation

The MA Series are fully 19” rack mountable. The rack you use should be a Double Door Rack where you 
can open the front and rear panel. When mounting the amplifier into the rack, please make sure that 
there is enough space around the amplifier for clear air flow.
Be careful when mounting the amplifier into the rack. Put the heaviest products into the lower part of 
the rack. The front panel is not designed to absorb acceleration forces occurring during transportation.

Inputs

Short cables runs improve the sound quality remarkably. Input cables should be short and direct, since 
high frequencies will mostly be absorbed if the cables are unnecessarily long. Besides that a longer 
cable may lead to hum or noise problems. If the cable runs are unavoidable, you should use balanced 
cables.

Outputs

The high damping factor of your amplifier supplies a clear sound reproduction. Unnecessarily long and 
thin cables used for low impedance (4-16Ω) speakers will influence the damping factor and thus the low 
frequencies in a negative way. In order to safeguard good sound quality, the damping factor should lie 
around 50. The longer a cable has to be the thicker it should be. For longer cable runs please ensure 
the 100V outputs are used for 100V speakers.
Connect your speaker systems via the speaker terminals (COM = -VE)
Examples:  

 1) COM + 4-16Ω

  

  

 2) COM + 70V

 

  

 3) COM + 100V

Note: Please do not use more than one pair of output terminals on any one output zone.

Connections To The Mains

Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the 
available supply is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth to be 
connected at all times. DO NOT remove or disconnect the earth.

Содержание CRAM38

Страница 1: ...15 15 BASS TREBLE 15 15 15 15 BASS TREBLE 15 15 15 15 BASS TREBLE 15 15 15 15 0 10 REMOTE MIC MIC 1 MIC 2 MIC 3 MIC 4 SIREN MIC LINE PHANT OM MIC LINE PHANT OM MIC LINE PHANT OM MIC LINE PHANT OM CHI...

Страница 2: ...able and all mains voltage connections with particular caution Never remove warning or informative labels from the unit Do not open the equipment and do not modify the unit Do not switch the equipment...

Страница 3: ...output across all zones 240Wrms 260Wpeak total output across all zones 350Wrms 375Wpeak total output across all zones Speaker output 70V 100V and 4 16 70V 100V and 4 16 70V 100V and 4 16 Minimum outpu...

Страница 4: ...switch 07 Protect 08 Clip 09 Signal 10 Power 11 AC 12 DC 13 Zone output attenuators 6 step 14 Zone selector LED indicator 15 All Zone selector LED indicator 16 MP3 FM Tuner Bluetooth module REMOTE MIC...

Страница 5: ...to sound distorted a reduction in gain may be required 4 LINE1 LINE2 HF LF Level controls During initial setup the high low frequency tone adjustment should be set to the zero point 12 o clock positio...

Страница 6: ...3 Output Zone Attenuators The output to each zone may be attenuated down in volume using each of the six step rotary attenuators on the front panel Certain functions of the amplifier such as paging an...

Страница 7: ...MODE button until the display shows USb or Sd If there is no USB stick or SD card inserted into the media player the option to select USB or SD will not be shown When playing music files from a USB d...

Страница 8: ...e highest setting The user may press and hold the buttons to change the volume 5 0 9 Number buttons FM tuner mode access to FM frequency i e for 97 4mhz frequency you can enter the three digits 974 an...

Страница 9: ...peration should be main 240V input fail The transfer is instantaneous and silent 4 Power Amplifier Outputs The main power amplifier output terminals may be used to output into either low impedance 4 8...

Страница 10: ...slave amplifiers or recording devices Each output features an unbalanced phono RCA 12 Telephone Input Volume Control The gain control is used to adjust the input gain for the telephone paging functio...

Страница 11: ...be the power slave amplifiers to prevent any unwanted noise or potential damage to speakers or amplifiers If you wish to power off the system turn the amplifier s master volume control counter clockwi...

Страница 12: ...tput zones will be restored to full volume during EMC alarms 2nd Telephone Remote Microphone Telephone and Remote Microphones override MIC1 MIC2 MIC3 MIC4 Line 1 Line 2 and Chime functions All six out...

Страница 13: ...nual 13 Typical Panel Connections Typical Panel Connections ON OFF CHIME VOL MASTER VOL MIC VOL CHIME 2 TONE 4 TONE LINK 24V 500m A POWER CD PLAYER CD PLAYER SLAVE AMP MIC 4 MIC 3 MIC 2 MIC 1 AC POWER...

Страница 14: ...e problems If the cable runs are unavoidable you should use balanced cables Outputs The high damping factor of your amplifier supplies a clear sound reproduction Unnecessarily long and thin cables use...

Страница 15: ...E EQ BASS TREBLE 2 STAGE EQ BASS TREBLE 2 STAGE EQ BASS TREBLE 2 STAGE EQ BASS TREBLE LEVEL MUTE_MIC1 LEVEL LEVEL LEVEL LEVEL LEVEL GND EMC LEVEL MASTER LI NE OUT 120W 240W switching power supply Powe...

Страница 16: ...revent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of...

Отзывы: