Setting the ON/OFF switch to
ON supplies power to relay K1 and power to one side
of the:
- heater contactor
- heater condenser
- fill solenoid
- drain solenoid
- rinse solenoid
These components can be activated by control components:
- relay K1
- TIMED/MANUAL switch
- timer control
- high level float switch
- low level float switch
• In units with the electronic key pad timer, the ON/OFF switch in the ON position
supplies power to one side of the timer countdown circuits through the
compartment thermal switch. The ON/OFF switch also supplies power to the 24-
volt transformer which provides control power to the key pad timer.
• In units with the mechanical dial timer, the ON/OFF switch set to ON supplies power
to one side of the 3 -second timer and buzzer for operation by the timer control.
Setting the ON/OFF switch to OFF removes power from the 120 VAC components
that control the steaming cycles, and starts the 3 -minute timer circuit, which starts
steam generator blowdown and float cylinder rinse.
Setting the ON/OFF switch to ON energizes relay K1, dosing the contacts of the
relay. This energizes the drain solenoid dosing the drain valve. Energizing relay K1
also energizes one side of the fill solenoid. The fill solenoid can be activated by the
high level float switch.
Setting the ON/OFF switch to OFF deenergizes relay K1, opening its contacts. This
prevents power from the 3-minute timer circuit from energizing the drain solenoid,
and dosing the valve, during generator blowdown.
Printed 12/90
Figur
e
5-4. ON/OFF Switch
TIMED/MANUAL Switch
(11, Figure 6-5)
Setting the ON/OFF switch to ON supplies power to the center terminals of the
TIMED/MANUAL switch. In the TIMED position (Figure 5-5), the TIMED/MANUAL
switch energizes the timer control circuit In the MANUAL position, the
TIMED/MANUAL switch energizes the heater contactor and condenser solenoid,
unless either the float low level switch or the high temperature limit switch is open.
• When electronic key pad units are in MANUAL mode, the opening of either the float
low level switch or the high temperature limit switch interrupts power to the
condenser solenoid and heater contactor.
• When mechanical timer units are in MANUAL mode, the opening of either the float
low level switch or the high temperature limit switch interrupts power to the heater
contactor only, the condenser solenoid remains energized.
Relay K1
(9, Figure 6-5)
Содержание steamcraft 21-CET-8
Страница 9: ......
Страница 53: ...Model 21 CET 8 Service Manual Page 45 Printed 12 90 ...
Страница 72: ...Model 21 CET 8 Service Manual Page 65 Figure 5 1 Block Diagram Key Pad Control Panel Printed 12 90 ...
Страница 104: ...Model 21 CET 8 Service Manual Page 97 Printed 12 90 ...
Страница 109: ...Figure 6 1 Major Component Groups Printed 12 90 ...
Страница 110: ...Page 104 21 CET 8 Service Manual Figure 6 2 Access Panel and External Components Printed 12 90 ...
Страница 112: ...Page 106 21 CET 8 Service Manual Figure 6 3 Steamer Compartment Group Printed 12 90 ...
Страница 114: ...Figure 6 4 Compartment Door And Hinge Assemblies Printed 12 90 ...
Страница 116: ...Page 110 21 CET 8 Service Manual Figure 6 5 Electronic Timer Control Panel Assembly Printed 12 90 ...
Страница 118: ...Page 112 21 CET 8 Service Manual Figure 6 6 Mechanical Timer Control Panel Assembly Printed 12 90 ...
Страница 120: ...Page 114 21 CET 8 Service Manual Figure 6 7 Electrical Components Assembly Printed 12 90 ...
Страница 122: ...Figure 6 8 Steam Generator Assembly Printed 12 90 ...
Страница 124: ...Figure 6 0 Heater Assembly Printed 12 90 ...
Страница 126: ...Page 120 21 CET 8 Service Manual Figure 6 1 OA Float Assembly Before Serial WC11379 901 01 Printed 12 90 ...
Страница 128: ...Page 122 21 CET 8 Service Manual Figure 6 10B Float Assembly After Serial WC11379 901 01 Printed 12 90 ...
Страница 130: ...Figure 6 11 Water Inlet System Printed 12 90 ...
Страница 132: ...Figure 6 12 Condenser And Drainage Systems Printed 12 90 ...
Страница 134: ...Figure 6 13 Equipment Stand Printed 12 90 ...
Страница 136: ...Figure 6 14 SteamCraft 3 1 Wiring Diagram Electronic Time Printed 12 90 ...
Страница 137: ...Figure 6 15 SteamCraft 3 1 Schematic Diagram Electronic Timer Printed 12 90 ...
Страница 138: ...Figure 6 16 SteamCraft 3 1 Wiring Diagram Mechanical Timer Printed 12 90 ...
Страница 139: ...Figure 6 17 SteamCraft 3 1 Schematic Diagram Mechanical Timer Printed 12 90 ...