Instruction of Fully Pneumatic Filling Machine of SGY Series
Chapter 2 Operation Instruction
2-1 Preparation
1. Precautions
(1)
The inlet air pressure should be 0.5-0.8Mpa and the working air pressure should
be 0.4-0.5 Mpa.
(2)
Keep all appendages clear of moving parts during operation.
2. Filling amount troubleshooting
Adjust the filling amount as follows:
(1)
Put materials to be filled into the container.
(2)
Prepare measuring cup or scale to identify quantities desired.
(3)
Turn the hand wheel to adjust the variable sensor to desired range.
(4)
Check to ensure that the operation switch is set to Semiautomatic, use the foot
pedal to control the cycle, measure the obtained product to see whether it is in
the desired quantity. If not, proceed by the following:
A
Loosen the locking handle on the adjustable sensor.
B
Turn the hand wheel clockwise or counterclockwise.
C
Repeat step 4, using a measuring cup or bottle to measure the materials and
adjust the handwheel until the obtained result is within the desired range.
D
Tighten the locking handle on the adjustment sensor to avoid parts shifting and
influencing the filling accuracy.