PROBLEM
POSSIBLE CAUSE
REMEDY/REFERENCE
Steamer not level
See note #2.
Hot Water to con denser
See note #2.
Reduced steam flow into cooking
Steam generator scale buildup.
Descale steam generator with approved
Compartment.
Descaler
Steam nozzle scale buildup.
See note #1.
Steam solenoids scale buildup
See note #1.
Electric models only
See note #4.
Voltage too low for unit.
Electric models only
See note #1.
Faulty heating element or controls.
Steam flow does not stop when
Operating in manual mode.
Switch to timed mode for timer to be
timer stops.
Effective.
Stuck open steam valve
See note #1.
Inoperative five controls inside
Turn off electricity at main disconnect
Cabinet.
switch. See note #1.
Water leaking from bottom of
broken or loose plumbing inside
Turn off electricity at main disconnects
Cabinet.
steamer cabinet.
switch and close water supply valve(s).
See note #1.
Water leaking from water pipes
Plumbing needs repair
See note #3.
or drain lines.
Food takes too long to cook.
Not enough steam movement in
Make proper connections. Refer to Service
(Cook in perforated pans when
compartment. Hot water con-
Manual.
possible.)
Connected to condenser line.
Pans too close to the bottom of
Put pans in racks near top of cabinet.
cabinet.
Steam generator scale buildup.
Descale steam generator with USDA
approved descaler
Compartment overloaded with
Put less food in pan. Use fewer pans.
too much food.
Voltage too low for unit.
See note #4.
Suggested cooking times are
Extend cooking times for altitudes above
usually listed for cooking at sea Level
2500 FEET.
Compartment bottom dirty with
Juices and /or food leaking from
Put a solid pan under perforated pans to
food drippings.
pans.
catch drippings, or put less food in pan.
TROUBLESHOOTING NOTES
1.
If problem is inside the steamer, call an authorized
Service representative Cleveland Range will not pay for
Non- warranty repair centers. For more information on
products and services, contact
2. Proper installation of the Convection Steamer
Responsibility of the owner or installer Refer to Cleveland
3.
A Licensed Electrician should do repair to external wiring.
For More information on products and services,
contact your nearest Authorized Service
Representative.