background image

MODELS

:

MKDT-12-T, MKDT-20-T

SE95016 Rev. 4

Operators Manual

Installation, Operation & Service

Direct Steam Table Top Mixers

MKDT-12-T

MKDT-20-T

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110

Phone: (216) 481-4900   Fax: (216) 481-3782

Visit our web site at www.clevelandrange.com

Cleveland

Enodis

Содержание MKDT-12-T

Страница 1: ... Operators Manual Installation Operation Service Direct Steam Table Top Mixers MKDT 12 T MKDT 20 T 1333 East 179th St Cleveland Ohio U S A 44110 Phone 216 481 4900 Fax 216 481 3782 Visit our web site at www clevelandrange com Cleveland Enodis ...

Страница 2: ...s may be extremely hot Use protective equipment Keep appliance and area free and clear of combustibles Stand clear of product discharge path when discharging hot product Wear protective equipment when discharging hot product Do not lean on or place objects on kettle lip Do not attempt to operate this appliance during a power failure Keep clear of pressure relief discharge Keep hands away from movi...

Страница 3: ...he following guidelines in preparing a shipping damage claim 1 Write down a description of the damage or the reason for suspecting damage as soon as it is discovered This will help in filling out the claim forms later If possible take a polaroid picture 2 As soon as damage is discovered or suspected notify the carrier that delivered the shipment 3 Arrange for the carrier s representative to examin...

Страница 4: ...10 45 psi steam pressure If the steam supply pressure exceeds 45 psi a pressure reducing valve is required The steam inlet is at the right side of the kettle as seen from the front CONDENSATE Maximum pressure rating on kettles is 50 psi It is highly recommended that a pressure relief valve equal to or less than this pressure be installed on the incoming steam line close to the kettle A steam conde...

Страница 5: ...LE WATER The water faucet optional with swing spout requires 1 2 inch O D copper tube plumbing for hot or cold water supplies to the faucet SPK cold water connection only DPK hot and cold water connection INSTALLATION CHECKS Although the kettle has been thoroughly tested before leaving the factory the installer is responsible for ensuring the proper operation of kettle once installed Final Install...

Страница 6: ...e Encloses agitator motors 6 Mixer Bridge Tilt Handle Used for tilting mixer bridge 7 Main Agitator Arm Provides most of the product movement 8 Secondary Agitator Arm Provides reverse agitation and product lift in kettle 9 Bayonet Mounts for Agitator Arms Allows removal of main and secondary agitator arms without tools 10 Marine Lock Prevents unit from accidental tilting 11 Steam Control Valve Man...

Страница 7: ...st After the kettle contents are heated and the boiler s steam pressure returns to normal the steamer may be used Pressure steamer compartments should be sequentially started and preheated before cooking NOTE As with cleaning food soil from any cookware an important part of kettle cleaning is to prevent food from drying on For this reason cleaning should be completed immediately after cooked foods...

Страница 8: ...ure setting 6 Drain unit 7 Rinse interior thoroughly 8 If the unit is equipped with a Tangent Draw Off Valve clean as follows a Disassemble the draw off valve first by turning the valve knob counter clockwise then turning the large hex nut counter clockwise until the valve stem is free of the valve body b In a sink wash and rinse the inside of the valve body using a nylon brush c Use a nylon brush...

Страница 9: ...ot be seen play it safe and use a soft cloth or plastic scouring pad 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the industry is providing an ever increasing choice of non chloride cleaners If you are not sure of chloride content in the cleaner used contact your cleaner supplier If your present cleaner contains c...

Страница 10: ...Mounting Bracket 1 11 FA11258 Hex Cap Screw 2 12 FA30505 Washer 2 13 FA21008 Hex Nut 2 14 SE50447 Washer Horseshoe 1 1 1 2 2 3 3 4 4 5 9 10 10 13 8 12 11 13 14 12 11 7 6 6 SERVICE PARTS WARRANTY Our Company supports a worldwide network of Maintenance and Repair Centers Contact your nearest Maintenance and Repair Centre for replacement parts service or information regarding the proper maintenance a...

Страница 11: ...6 KE51919 Fuse 10 Amp 115v motor 2 KE51920 Fuse 5 Amp 230v motor 2 7 KE51139 Fuse Holder single 2 KE51228 Fuse Holder double 2 8 KE0753 1 Relay 12 VAC 1 9 KE54761 Terminal Block Mounting Strip 1 10 SK50055 1 Terminal Block 3 11 SK50054 2 Terminal Block End Anchor 1 12 SK50054 1 Terminal Block End Barrier 1 13 KE50581 Bridge Rectifier 1 4 5 2 3 1 13 6 7 8 12 11 10 9 CONTROL HOUSING ...

Страница 12: ...STEAM CONTROL ASSEMBLY 1 15 16 2 3 4 5 5 22 6 7 8 9 10 1 13 14 21 20 19 18 17 25 4 23 24 12 4 5 3 21 20 19 18 17 5 6 7 8 9 4 23 7 8 9 23 6 7 8 9 4 23 13 12 5 26 28 27 29 11 ...

Страница 13: ...1092 Binding Head Screw 8 32 x 1 2 lg 1 14 KE50151 E Knob threaded after 07 94 1 KE50151 Knob non threaded prior to 06 94 1 15 KE50886 3 Handle KDT 6 T KDT 12 T 1 KE50886 4 Handle KDT 20 T 1 16 KE50475 Plug Button 1 17 KE52697 Lock Nut 1 2 NPS 2 18 FA32500 Lockwasher 2 19 FA30502 Washer satin coat 2 20 KE50467 Washer Foot 2 21 KE50463 Service Pipe KDT 12 T 2 KE50464 Service Pipe KDT 20 T 2 22 KE00...

Страница 14: ...BRIDGE ASSEMBLY ...

Страница 15: ...C 3 4 H P 240 V 1 14 FA95014 Key 3 16 x 3 16 x 1 1 15 KE51900 Connector Conduit 1 16 KE51916 Conduit MKDT 12 T 1 KE51917 Conduit MKDT 20 T 1 17 KE50151 Knob Handle 1 18 KE51801 Pin Bridge Support MKDT 12 T 1 KE51802 Pin Bridge Support MKDT 20 T 1 19 KE00847 Bridge Support Post MKDT 12 T 1 KE00848 Bridge Support Post MKDT 20 T 1 20 KE51809 Coupling Primary Shaft 1 21 KE00831 Agitator Primary MKDT 1...

Страница 16: ...GEAR BOX NOTE Insert bolts in opposite holes for taper lock bushing removal A ...

Страница 17: ...265 Upper Body Casing MKET 20 T 1 4 KE50268 Bushing Small Gear 1 5 KE50266 Bearing Small Gear 2 6 KE50259 Bearing Large Gear 2 7 KE51245 Spacer MKDT 12 T 1 8 KE50299 Gear Large Spur MKDT 12 T 1 KE00105 Gear Large Spur MKDT 20 T 1 9 FA95003 Key Woodruff 2 10 KE00106 Gear Small Spur 1 11 KE50264 Shaft Driving 1 12 KE50261 Shaft Driven MKDT 12 T 1 KE50260 Shaft Driven MKDT 20 T 1 13 KE50269 Bushing L...

Страница 18: ...te If the kettle s cooking performance becomes inadequate after long use replacement of the steam trap with a new one may restore kettle operation to peak efficiency MARINE LOCK Inspect lock at least twice yearly 1 Check for excessive play or wear on pivot Adjust or replace as required 2 Insure lock is catching over the centre of the stop pin and not bent to one side or the other Adjust or replace...

Страница 19: ... are not always the same When checking make certain that the original state ie fresh or frozen and quantity of food product is the same PROBLEM B The trunnion housing leaks steam Probable Cause Remedy 1 Trunnion O rings are worn Replace O rings see Steam Control Assembly drawing Gas Input Steam Output Boiler BTU Hour Lbs Hour H P 100 000 60 1 7 160 000 95 2 8 200 000 125 3 6 250 000 150 4 4 300 00...

Страница 20: ...WIRING DIAGRAM ...