FOR YOUR
SAFETY
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE LIQUIDS AND
VAPOURS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.
GENERAL INSTALLATION INSTRUCTIONS
Installation of kettle must be accomplished
by qualified installation personnel, working to
all applicable local and national codes.
Improper installation of product could cause
injury or damage.
This equipment is built to comply with
applicable standards for manufacturers.
Included among those approval agencies are:
UL, A.G.A, NSF. ASME/N.Bg, CSA, CGA, ETL,
and others. Many local codes exist, and it is
the responsibility of the owner and installer to
comply with these codes.
Observe all clearance requirements to provide
proper make-up air flow as well as sufficient
clearance for servicing. Dimensions and
clearance specifications are shown on the
specification sheet. Do not install kickplates or
otherwise obstruct the flow of combustion and
ventilation air. Check the rating plate to ensure
that the kettle has been equipped to operate
with the type of gas available at the installation.
Gas fired kettles are only to be installed under
a ventilation hood in a room which has
provisions for adequate make up air.
Electrical installation must be in accordance
with local codes and/or the National Electric
Code ANSI/NFPA 70-1987 (USA) or the
Canadian Electrical Code CSA Standard C22.1
(Canada). The kettle must be electrically
grounded by the installer. Standard supply
voltage is 115 volts A.C. However, optional
A.C. voltages can be supplied on special order.
A separate fused disconnect switch must be
supplied and installed in the high voltage
electrical supply line. The wire gauge size and
electric supply must match the power
requirements specified on the kettle's rating
plate. The conduit-enclosed permanent copper
wiring must be adequate to carry the required
current at the rated voltage. Refer to the
specification sheet for electrical specifications
and location of electrical connections.
INSPECTION
Before unpacking visually inspect the unit for
evidence of damage during shipping. If
damage is noticed, do not unpack the unit,
follow shipping damage instructions.
SHIPPING DAMAGE INSTRUCTIONS
If shipping damage to the unit is discovered or
suspected, observe the following guidelines in
preparing a shipping damage claim.
1.
Write down a description of the
damage or the reason for suspecting
damage as soon as it is discovered.
This will help in filling out the claim
forms later.
2. As soon as damage is discovered or
suspected, notify the carrier that
delivered the shipment.
2
- -IF YOU
SMELL GAS - -
1. OPEN WINDOWS
2. DO NOT TOUCH
ELECTRICAL SWITCHES.
3. EXTINGUISH ANY OPEN FLAME.
4.
CALL YOUR GAS
SUPPLIER IMMEDIATELY.