Cleveland CE-975 Скачать руководство пользователя страница 5

CE-975 

Operator’s Manual 

 

 

Page 4 

 

  CE-975 

Operator’s 

Manual 

 

 

VI. Operation steps: 

1. Turn on the power switch (look at whether the voltage is normal), start the cooling fan, delay for 5 seconds and make the 

main circuit work, press the seal switch to make the seal work.   

Note: it is prohibited to continuously and rapidly switch on and off the power supply and seal switch! Wait for at least 5 

seconds after turning off the power switch, then re-open the power supply, or else, it would be easy to damage the equipment.   

2. Adjust the sensing head to make it higher than the sealed object by 1 to 3mm. Place the sealed objects on both ends of the 

sensor head, and check whether the sensor head and the conveyor belt are parallel. If not parallel, adjust the pillar below the conveyor 

belt to make it parallel.  

3. According to the bottle diameter, select the sealing range of the sensor head.  

4. Press down the sealing switch, and try sealing. If the sealing is not firm, reduce the speed of conveyor belt. If 

the  sealing  membrane  is  burnt,  increase  the  conveyor  speed  or  increase  the  sensor  head.  After  the 

requirements on sealing quality are met, continuous automatic sealing operation can start.   

5. To ensure that the seal will be always in the best working condition, conduct the sealing process 

test,  to  identify  the  optimum  process  parameters  and  make  records.  After  debugging  is  done,  prevent 

accidental  changes  in  the  normal  production.  Also  conduct  regular  sampling,  to  avoid  sealing  of  the 

substandard products.   

6.  When  the  operating  current  is  excessive,  the  machine’s  over-current  protection  function  is 

activated,  and  the  conveyor  belt  automatically  stops  working.  At  this  time,  appropriately  pull  up  the 

spacing between sensor head and sealed object, to reduce the operating current. After adjustment, re -boot 

the machine to proceed with the sealing operation.   

7. When the temperature of main circuit of the equipment is excessively high, the thermal overload 

protection  function  is  activated,  and  the  equipment  automatically  stops  working.  After  the  temperature 

drops to the normal state, the equipment will automatically start the sealing operation.   

 

VII. Maintenance and repair: 

1.  The  machine  is  electromechanical  integration  equipment.  In  order  to  avoid  the  equipment 

appliance from premature aging and damage, the working environment must remain clean and dry. Also, 

it is prohibited to use the machine in environment of high humidity, high corrosion, and high dust.   

2. The instrument switches on the operator control panel shall not be immersed with water or other 

liquids,  so  as  not  to  cause  damage  or  leakage.  During  operation,  do  not  use  excessive  force,  so  as  to 

extend the service life.   

3.  The  transmission  part  should  be  often  added  with  the  proper  amount  of  lubricants,  and  no 

phenomena of blockade or serious friction should exist.   

4.  The  sensor  head  and  the  electrical  appliance  in  the  chassis  have  high-voltage  electricity.  The 

untrained professional electrician shall not open the sensor head and the back cover of the electrical box, 

to avoid electric shock accidents. 

 