(NOT TO SCALE)
SECT.
III
PAGE
12
1007
Litho in U.S.A.
Right - 6”, Left - 6”, Rear - 6” (12”
on control side if adjoining wall
or equipment is over 30” high for
service acess)
For use in non-
combustible locations.
Contact factory for
variances to clearances
1 1/2” IPS common drain.
Do not connect other units
to this drain.
Do not use PVC pipe for
drain.
Each compartment has capacity for:
•
Three, 12˝ x 20˝ x 2
1
⁄
2
˝ or six, 12˝ x 20˝ x 1˝ deep
Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be neces-
sary. The fact that a water supply is potable is not proof
that it will be suitable for the generator.
NOTES
:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA (AGA, CGA).
** Do not connect to GFI
outlet. See note below.