6 Defects
Defect code-1
100000
100000
Reserve
Defect code
LED Intervall 1 LED Interval 2 Description
Defect code-2
110000
110000
To little water - cause:
- Inlet does not open
- Water supply closed / too little
- Inlet time too little (configuration)
Defect code-3
111000
111000
Safety Sensor switched off
Defect code-4
111100
111100
Temperature sensor does not show a
signal
Defect code-5
111110
111110
Function / defect code is not in use
Reserved: “Cabin does not reach
temperature”
Defect code-6
111111
111111
Water inlet defect / leaking
Water level at start at max
Defect code-7
111111
100000
Water sensor min / max does not
work
- Cable has been changed?
A defect is shown on the display.
By counting the number of LEDs that light up, it becomes clear which defect is reported. Below a few
examples:
-When 2 LEDs light up, code 2
-When 5 LEDs light up, code 5
To reset the defect, the steam button must be pressed for 5 seconds. Of course, the defect must be
repared, otherwise it will return. The display goes completely dark after this action.