User Manual – ZPLUG
UM_ZPLUG_20090903_001_04_00.doc
CLEODE Page 8 sur 14
II ZPLUG
DESCRIPTION
II.1 Z
IG
B
EE PRESENTATION
The ZPLUG contains an application with :
Switching on/off the appliance plugged into the plug. This is based on the
MainPowerOutlet application defined in the ZigBee Home Automation profile.
The measure of the consumption of the appliance plugged into the plug. The power
socket can accept devices up to
3500 watts
.
For more detail on the data exchange between device and network, see documents [1], [2], [3]
and [4].
The ZPLUG embedded the router functionality with amplified signal up to + 20 dBm. This
means that the ZPLUG is able to extend the ZigBee Network.
II.2 DESCRIPTION
OF
THE
AVAILABLE
INFORMATION
The switching is made by sending a command On/Off on the
On/Off
cluster.
The simple metering is used to monitor how much electricity an appliance plugged into it is
using. This application is able to send the current demand of energy in KW and the most
recent summed value of energy used in KWh.
II.2.1
D
ESCRIPTION OF THE APPLICATION
Device ID : Mains Power Outlet
Endpoint : 1
Clusters :
Côté serveur
Côté client
Basic (0x00)
/
Identify (0x03)
/
Groups (0x04)
/
Scenes (0x05)
/
On/Off (0x06)
/
Simple Metering (0x0702)
/