background image

 

User Manual: ZCARE : Warning Wristband 

CLEODE 

 

page 

15

 

of 

22

 

 

IV.

 

Proceedings 

IV.1

 

Activate/Desactivate fonctionnalities of wristband 

Two main functions can be active/desactive on the wristband: 

1.

 

Management of emergency calls 

2.

 

Management of fall detections  

IV.2

 

Management of emergency calls 

Activation/desactivation  of  the  management  of  emergency  calls  is  done  via  the  attribut 

ManualFunction

  of  the

 

cluster 

Care Configuration

 (Cf. paragraph V.2.2.6)  

To activate the management of emergency call, put the attribute at 1 

To desactive the management of emergency call, put the attribute to 0 

 

By default, this feature is activated 

 the attribut 

ManualFunction

 

is set by default to 

1

To modify the value of this attribute, it is necessary to switch the wristband in config 
mode : Cf. paragraph III.5 

 

When  an  emergency  call  is  sent  off  by  pushing  on  the  call  button,  the  wristband  inform  that  the  call  has  been 
seen by flashing during 2 seconds the LED NWK in red 

IV.3

 

Management of falls detections  

Activation/desactivation of the management of falls detactions is done via the attribute 

FallFunction

 of the cluster 

Care Configuration

 (Cf. paragraph V.2.2.6)  

To active the management of falls detection, put the attribute to 1 

To desactive the management of falls detection, put the attribute to 0 

 

By default, this feature is desactivated  

 the attribute 

FallFunction

 is set by default to 

0

To modify the value of this attribute, it is necessary to switch the wristband in config 
mode : Cf. paragraph III.5 

 

When a fall is  detected by the wristband Zcare, the wristband inform that an alert has been done  in flashing 2 
seconds the LED NWK in red. 

Содержание ZCARE

Страница 1: ...ION France T 33 0 2 96 48 68 18 F 33 0 2 96 48 19 11 SAS au capital de 167 200 450 570 767 RCS Saint Brieuc User Manual ZCARE Warning Wristband References ZCARE 2 0 Revision 1 0 Date 08 31 2018 State...

Страница 2: ...e une quipe m dicalis e qui par ailleurs effectuera elle m me les v rifications sur l tat de sant du porteur du wristband ZCare L utilisation du produit ZCare sous entend de la part de l utilisateur...

Страница 3: ...the devices in order to comply with the warranty The warranty does not apply to replacement or repairs that may result from normal wear and tear of devices systems or products damage or accidents res...

Страница 4: ...User Manual ZCARE Warning Wristband CLEODE page 4 of 22 Table of content Version Author s Version description Date 0 1 CLEODE Initial version 05 22 2018 1 0 CLEODE Validated document 05 29 2018...

Страница 5: ...ICHING PROCEDURE IN STANDBY MODE 13 III 5 PROCEDURE TO SWITCH IN CONFIG MODE 14 IV PROCEEDINGS 15 IV 1 ACTIVATE DESACTIVATE FONCTIONNALITIES OF WRISTBAND 15 IV 2 MANAGEMENT OF EMERGENCY CALLS 15 IV 3...

Страница 6: ...TION PROCEDURE IN THE ZCARE PRODUCT IN A ZIGBEE NETWORK 12 FIGURE 4 ERASING ZIGBEE NETWORK SETTINGS 12 FIG 5 SWING PROCEDURE IN STANDARD MODE 13 FIGURE 6 SWINGING PROCEDURE IN STANDARD MODE 14 FIGURE...

Страница 7: ...ZigBee secure Home Automation 1 2 Modes de fonctionnement Alerte manuel Manual alert D tection de chute Warning fall G olocalisation dans un r seau ZigBee avec routeurs CLEODE de type Vigilance Geolo...

Страница 8: ...ry Type Li Polymer 150mAH Type de chargeur Charger Type Chargeur sans fil compatible QI V1 2 WPC Wireless charger QI WPC compliant RF Norme radio Radio Standard ZigBee mode s curis ZigBee secure mode...

Страница 9: ...toutes les directions IP65 enclosure no ingress of dust protected against low pressure jets of water from all directions Temp rature d utilisation Operating temperature range 20 C to 70 C ambient Temp...

Страница 10: ...pter Peering III 2 2 Activate functions of the wristband for more details look at chapter Configuration IV 1 3 Shift in regular mode for more details look at chapter Configuration III 3 4 Manage the w...

Страница 11: ...e is under maintenance included in ZigBee Network and available The call and fall functions stay inactive 3 Standard mode the wristband ZCare is integrated in the ZigBee Network and available The call...

Страница 12: ...uring 2 seconds 6 ZCare produtc then swithovers in configuration mode it is reachable by devices of integration network POLL_RATE of 1 second Once configurated it is recommanded to swith in standard m...

Страница 13: ...erform the previous procedures to arrive at this state 1 Approach the magnet on the LED NWK side then click on the call button 2 The ZCare flashes 2 quickly Red to signal new status Standard mode Once...

Страница 14: ...functions of the wristband Cf Chapter Software Interface V To switch in configuration mode proceed as below we consider here that the wristband is already associated to the ZigBee network Figure 7 Pro...

Страница 15: ...it is necessary to switch the wristband in config mode Cf paragraph III 5 When an emergency call is sent off by pushing on the call button the wristband inform that the call has been seen by flashing...

Страница 16: ...he wristband ZCare IV 5 Wristband loading Wristband ZCare is loading by a standard wireless charger QI V1 2 Proceed as follow 1 Put the wristband on the loading place 2 The wristband signal the activa...

Страница 17: ...Alarms 0x0009 IAS Zone 0x0500 Care Configuration 0xFC0A V 2 2 Clusters Description The Clusters description and attributes managed by ZCare is as follow V 2 2 1Cluster Basic Attribute Attribute ID ZC...

Страница 18: ...al the new value of the attribute ZoneStatus Attribut Attribut ID ZoneState 0x0000 ZoneType 0x0001 ZoneStatus 0x0002 IAS_CIE_Address 0x0010 The attribute ZoneState allows to know if the wristband is e...

Страница 19: ...the fall and g 0xFF Example 0x7D70 correspond to a difference of place of Then more ThresholdDeltaVectorSum ist low less the position change is think about by the algorithm of fall detection A thresh...

Страница 20: ...User Manual ZCARE Warning Wristband CLEODE page 20 of 22 Fig 9 Principe of validation of a heavy fall...

Страница 21: ...ed and context The delay is about 4 weeks Repair is done Repair is assured by the manufacturers of the material elements to not cancel the guarantee of the element The information on the label is as f...

Страница 22: ...for support should be send to the postal address or by e mail At support cleode com CLEODE S A S Support and Maintenance 3 rue Thomas Edison 22300 Lannion Tel 33 0 2 96 48 68 18 Fax 33 0 2 96 48 19 1...

Отзывы: