User Manual: ZCARE : Warning Wristband
CLEODE
page
15
of
22
IV.
Proceedings
IV.1
Activate/Desactivate fonctionnalities of wristband
Two main functions can be active/desactive on the wristband:
1.
Management of emergency calls
2.
Management of fall detections
IV.2
Management of emergency calls
Activation/desactivation of the management of emergency calls is done via the attribut
ManualFunction
of the
cluster
Care Configuration
(Cf. paragraph V.2.2.6)
To activate the management of emergency call, put the attribute at 1
To desactive the management of emergency call, put the attribute to 0
By default, this feature is activated
the attribut
ManualFunction
is set by default to
1
.
To modify the value of this attribute, it is necessary to switch the wristband in config
mode : Cf. paragraph III.5
When an emergency call is sent off by pushing on the call button, the wristband inform that the call has been
seen by flashing during 2 seconds the LED NWK in red
IV.3
Management of falls detections
Activation/desactivation of the management of falls detactions is done via the attribute
FallFunction
of the cluster
Care Configuration
(Cf. paragraph V.2.2.6)
To active the management of falls detection, put the attribute to 1
To desactive the management of falls detection, put the attribute to 0
By default, this feature is desactivated
the attribute
FallFunction
is set by default to
0
.
To modify the value of this attribute, it is necessary to switch the wristband in config
mode : Cf. paragraph III.5
When a fall is detected by the wristband Zcare, the wristband inform that an alert has been done in flashing 2
seconds the LED NWK in red.