Installation Guide / PostMount 1-A for XL Panel
6
Code-Compliant Planning and Installation Guide V 1.1 - Complying with AS/NZS1170.2-2011 ADMT 4-2016
- Installation Instruction -
Installation Instruction
Dig a hole with the diameter of 300mm.
Place the pole into the middle of the hole and fillit with concrete.
Maintain the position of the post. The allowed vertical tolerance is
±2°.Keep the axle of the 2- Ø14 holes parallel to East-West;keep the
vertical angle deviation within ±5°.For more than one system on one
site maintain all the axles of 2- Ø14 holes aligned.
1) As show in figure on the right, with M12 * 120 hex bolts and nuts to
lock Angle Steel 63*40*1250 on the Pole. And then use M12 * 120 hex
bolts and nuts to lock supporting rod 40 * 40 * 682 on the Pole.
Note:
supporting rod around multiple holes which can be adjusted by
adjusting the mounting,adjustable angle of 10 °, 20 °, 30 °, 40 °, 50 °
and 60 °.
Recommended torque for M12 bolts is 40~45 N·m
2) As show in figure on the right, place the ECO-Rail on Angle Steel.
Use the Cross Connection Clamp, Cup head square neck bolts M8*25,
Hexagon nut with flange M8 to lock on the Angle Steel 63 * 40 * 1010
Recommended torque for M8 bolts is 18~20 N·m
1. Pole 83*2400 Installation
2. PostMount 1-A Kit Installation