7.9
Tube-Lock Fittings ‒ Figure 37
Failure to observe the following procedure
before performing any maintenance can cause
injury from the sudden release of trapped
compressed air.
Lockout and tagout the compressed-air
supply.
Bleed all compressed air-supply lines.
Figure 37
7.9.1
To remove the tubing, push the retaining collar
toward the fitting, which releases the tubing so it can be
easily removed by pulling it out. Do not force it; only a
slight pull on the tubing is required if the retaining collar
is pushed in correctly.
7.9.2
Reconnect the tubing by inserting it through the collar
until it seats. Tug on the tubing to make sure it is secured.
7.10
Servicing Pneumatic Inlet Assembly – Figure 38
Turn off the compressed-air supply, bleed the
supply line and perform lockout and tagout
procedure to the air-supply line. Failure to do
so can cause injury from the release of trapped
compressed air
7.10.1
To service or replace any module in the
pneumatic inlet assembly, the mounting clips that
attaches it to the part next to it must be loosened or
removed. Use a TORX T20 screwdriver to loosen the
mounting screws enough to remove the part. NOTE: If a
TORX-T20 is not available use a flat-blade screwdriver
that fits into the slot.
7.10.2
Modules are sealed against the one next to it
with an O-ring. The O-ring must be in place before
reattaching them to the mounting bracket.
Figure 38
Filter
Mounting Bracket
O-Ring
Retaining Clip
O-Ring
Branch Module
Pilot-Operated
Pressure Regulator
Mounting Screws
To remove the tubing:
Push the
collar in to release the tubing.
Pull the tubing straight out to
remove it from the fitting.
Retaining Collar
To connect the tubing:
Push
the tubing into the fitting until it
seats. Gently pull on the tubing to
make sure it is securely fastened.