PULSAR
®
PLUS 55-S SUCTION BLAST CABINET
Page 9
© 2021 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 30423
Figure 6
2.2.2
Use a 3/4" ID or larger air-supply line from the
air source to the air filter located on the power module. A
smaller diameter hose may reduce blasting efficiency.
2.2.3
Refer to Figure 6
and apply thread sealant to
the male threads of an air fitting that is compatible with
the air-supply hose fitting, and then install it onto the 1/2"
NPT air filter (pneumatic inlet assembly) located on the
power module. The style of connection shown in Figure
6 is for reference only.
2.2.4 Connect the air
supply line to the previously
installed air fitting.
Hose disconnection while under pressure can
cause serious injury or death. Use safety lock
pins or safety wire to lock twist-on couplings
together and to prevent accidental separation,
and use safety cables to prevent hose from
whipping should separation occur. Safety lock
pins and safety cables are listed in
Section
10.1: Optional Accessories.
2.3
Ground the Cabinet
and Power Module
2.3.1
To prevent static electricity buildup, attach an
external grounded wire from an earth ground to the
grounding lug on the power module.
2.4
Connect Electrical Service
Shorting electrical components can result in
serious injury or death from electrical shock or
equipment damage. Electrical power must be
locked out and tagged out before performing
any electrical work. All electrical work or any
work done inside a control panel or junction
box must be performed by a qualified
electrician and comply with applicable codes.
2.4.1 Standard single-phase wiring
Standard Pulsar Plus cabinets are 120-volt single phase.
Power is supplied by a U-ground plug; plug it into a 120-volt
outlet. No additional wiring is needed; a wiring schematic is
stowed inside the electrical control panel for reference.
Do not use electrical adaptors that eliminate the
ground prong on 120-volt plugs. Doing so can
cause electrical shock and equipment damage.
2.5
Set Air-Inlet Damper ‒ Figure 7
Located on the top-rear edge of the cabinet, as shown in
Figure 1.
1/2" NPT Air Filter
Secure safety cable to the power module to prevent it from slipping off.
Air-Supply Hose, 3/4" ID or larger
Air Fitting
Use safety cable to prevent separated hose from whipping.
Once installed, remove all slack from the cable.
Apply thread sealant to male NPT threads
.
The type of air fitting and hose connections are for reference only.
When using twist-on couplings, install safety lock pins to prevent accidental disconnections.
Pneumatic Inlet Assembly