PULSAR
®
III-P/III-PE and VI-P/VI-PE PRESSURE CABINETS
Page 11
© 2019 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 21527, Rev. I, 02/19
Figure 12
the panel. NOTE: Make sure the panel is close enough
to the dust collector for 10 feet of tubing to reach.
3.6.4
Remove 1/4" pipe plugs from the dust collector
body and install 1/4" x 1/8" bushings and snubber
fittings, as shown in Figure 12.
3.6.5
Connect the 1/4" tubing to the snubber fittings
and gauge as shown by removing the fitting’s
compression nut, sliding it over the end of the tubing,
inserting the tubing into the fitting, and tightening the nut
onto the fitting.
3.6.6
Refer to the differential-pressure-gauge manual
provided for operation of the gauge.
3.7
Armrest
3.7.1
Assemble the armrest and mounting brackets,
as shown in Figure 13.
3.7.2
Position the assembly so the armrest is about
even with the bottom of the arm port opening. Mark one
hole location on the front of the cabinet at each
mounting bracket.
3.7.3
Drill a 3/8" hole at both locations and mount the
armrest using 5/16 cap screw, washers, and nuts. Install
the bolts from inside the cabinet to protect the threads from
abrasion, should the armrest need to be removed later.
3.7.4
Match drill the remaining four bracket holes and
install the remaining fasteners.
Figure 13
3.7.5
Loosen the fasteners on the slotted bracket and
raise or lower the armrest to a comfortable position.
5/16 x 1" Cap Screw,
Flat Washer, Lock
Washer, and Nut
3/8 x 1" Cap Screw
and Lock Washer
Armrest
Inline Filter, arrow pointing toward the gauge.
To Hi (+) Port on Gauge.
Tubing from the dirty side of the
collector (lower snubber) connects to
fitting with the inline filter and Hi (+)
port on the differential-pressure gauge.
Upper Snubber
1/4" x 1/8" Bushing
Lower Snubber
Tubing from the clean side of the
collector (upper snubber) connects
to fitting leading to the Lo (-) port
on the differential-pressure gauge.
To Lo (-) Port on Gauge
Upper snubber is clean side of
collector, to Lo (-) port.
Lower snubber is dirty side of
collector, to filter and Hi (+) port.
Differential-Pressure
Gauge
Gauge Panel
Remove pipe plugs and install
bushings and snubber fittings.