background image

SUPERVISOR CONTROLS

Tennant T300e/T300 (03- 2015)

51

ATTENTION:

The following instructions are intended

for supervisor use only. Remove pages from manual if

necessary.

SUPERVISOR CONTROLS

The supervisor controls feature allows a supervisor to

program the machine’s scrubbing settings for operator

use. The lockout functionality will prevent the operator

from changing or saving the Zone Settings.
The supervisor controls feature will lower machine

variability for consistent, repeatable cleaning results,

machine quality assurance regardless of user

experience, and reduce user training requirements.

NOTE: The T300e model is not equipped with the

supervisor controls feature.

T300 MODEL WITH MEMBRANE CONTROL PANEL

The machine has three supervisor control modes of

operation to choose from:

Unlocked Mode 1:

Operator has full control of all

scrubbing parameters with the ability to save Zone

Settings. The Unlocked Mode 1 is the factory default

setting.

Lockout Mode 2:

Zone Settings are configured and

locked by supervisor. Operator has control to

reconfigure the zone settings, but are not able to save

them.

Lockout Mode 3

: Zone Settings are configured and

locked by supervisor. Operator is restricted to only use

the Zone Settings configured by supervisor.
To enter the supervisor controls mode follow the

instructions below:
1. Park the machine on a level surface and turn the

key to off ( O ) position.

2. Press and hold the Down Pressure button while

turning the key on. Release button when the far

right battery discharge indicator LED turns on

(Figure 132).

FIG. 132

3. Select the preferred supervisor control mode by

pressing the following Zone Setting buttons as

described:
Zone 1 button = Unlocked mode 1

Zone 2 button = Lockout mode 2

Zone 3 button = Lockout mode 3

Hold down the Zone Setting button until it blinks

three times to save the preferred supervisor control

mode (Figure 133). In this example, Lockout mode

3 was selected.

FIG. 133

4. If Lockout mode 2 or 3 was selected, press the

Solution Flow button. This will allow you to

configure the Zone Settings for the selected

supervisor control mode (Figure 134).

FIG. 134

5. Configure the following Zone Settings for zone 1.

After the Zone Settings are configured, press and

hold the zone button until it blinks three times to

save Zone Setting. Repeat process for other

zones.
Zone Settings:
- Down pressure rate
- Solution flow rate
- Quiet-Mode on or off (option)
- ec-H2O mode on or off (option)
- Maximum scrubbing speed (drive model)
To adjust the maximum scrub speed, press the

circled button to cycle through the five speed

selections as described below (Figure 135).
The speed selection is displayed by the battery

discharge indicator LED’s. The red LED represents

the lowest speed. The far right green LED

represents the highest speed (Figure 135).

FIG. 135

6. To exit the supervisor control mode, turn key off.

Содержание TENNANT T300

Страница 1: ...T300 SCRUBBER DRYER OPERATOR MANUAL Clemas Co Unit 5 Ashchurch Business Centre Alexandra Way Tewkesbury Gloucestershire GL20 8NB Tel 01684 850777 Fax 01684 850707 Email info clemas co uk Web www clema...

Страница 2: ...44 EN ISO 3741 EN ISO 13059 EN ISO 3450 EN 60335 2 72 EN according to Annex II A of the Machinery Directive Ives Franssen Operation Manager TENNANT N V Industrielaan 6 5405 AB P O Box 6 5400 AA Uden T...

Страница 3: ...18 T300 WITH MEMBRANE CONTROL PANEL 18 T300 MODEL WITH PRO PANEL CONTROLS 19 MACHINE OPERATION 23 PRE OPERATION CHECK LIST 23 OPERATING MACHINE 23 WHILE OPERATING MACHINE 25 EMERGENCY SHUT OFF BUTTON...

Страница 4: ...driver brush can be harmful to pacemaker wearers or medical implants This machine may be equipped with technology that automatically communicates over the cellular network If the machine will be opera...

Страница 5: ...ncompatible battery chargers as this may damage battery packs and potentially cause a fire hazard Inspect charger cord regularly for damage Keep work area well ventilated Avoid contact with battery ac...

Страница 6: ...battery cables before servicing machine Located on circuit board panel WARNING LABEL Spinning pad Keep hands away Located on disk scrub head model WARNING LABEL Magnetic field hazard Magnetic pad driv...

Страница 7: ...ry compartment 8 Accessory rail s 9 On board battery charger cord hooks 10 Scrub head lift pedal 11 Squeegee foot pad 12 Squeegee assembly 13 Control handle 14 Control handle start bail 15 Speed contr...

Страница 8: ...Panel 3 1 2 4 1 Service indicator Lights up when a machine or charger fault is detected 2 Parking brake indicator Lights up when parking brake lever is engaged To turn off indicator disengage parking...

Страница 9: ...n The factory zone settings are configured with different solution flow rates down pressures and maximum scrub speeds T300 Model with Pro Panel Controls LCD Liquid Crystal Display 10 1 7 2 3 5 8 9 4 1...

Страница 10: ...BLACK RED FIG 2 IMPORTANT Make sure that the machine s battery charger is properly set before charging See BATTERY CHARGER SETTINGS BATTERY PACK LIFT OUT TRAY Option Models equipped with the optional...

Страница 11: ...or pad to use Contact a Tennant representative for specific recommendations Soft nylon bristle scrub brush White Recommended for cleaning coated floors without removing finish Cleans without scuffing...

Страница 12: ...NSTALLING BRUSH PAD 3 Lug Disk T300e FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine remove key and set parking brake if equipped 1 Step down on the scrub head li...

Страница 13: ...as shown Figure 13 FIG 13 INSTALLING BRUSH PAD Insta Click Magnetic Disk FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine remove key and set parking brake if equip...

Страница 14: ...ng machine stop on level surface turn off machine remove key and set parking brake if equipped 1 Step down on the scrub head lift pedal to raise the scrub head off the floor Figure 19 FIG 19 2 Install...

Страница 15: ...indicator Figure 27 ec H2O Scrubbing Only use cool clean water less than 21 C Do not use hot water or add conventional floor cleaning detergents An ec H2O system fault will occur if cleaning detergent...

Страница 16: ...ank when refilling the solution tank 3 Adjust the mixing ratio knob according to the cleaning detergent s mixing instructions Figure 31 FIG 31 ec H2O NanoClean WATER CONDITIONING CARTRIDGE ec H2O mode...

Страница 17: ...Option If model is equipped with the optional accessory clips the clips easily clip on and off the rails for additional accessory storage Figure 35 FIG 35 To install the accessory clips hook the clip...

Страница 18: ...ow setting No LED No flow One LED Low flow two LED s Medium flow three LED s High flow FIG 40 4 Models equipped with Severe Environment button option Press Severe Environment button one time to dispen...

Страница 19: ...PRO PANEL CONTROLS There are two types of user modes that will interface with the operator home screen Operator Mode Capable of machine operation with permissions and restrictions controlled by the s...

Страница 20: ...ressure Press the symbol to decrease the down pressure FIG 49 4 Press the solution flow icon to display the solution flow scale Figure 50 Press the symbol to increase solution flow Press the symbol to...

Страница 21: ...press and hold the zone number button until it prompts you to name the new zone setting Select yes to enter a new name Figure 55 By selecting no the preset name will be removed NOTE Only the superviso...

Страница 22: ...n will flash yellow or red when a machine fault is detected Figure 60 FIG 60 In conjunction with a flashing service indicator icon the following fault screens will automatically pop up to indicate the...

Страница 23: ...The ec H2O system will automatically turn on at start up To turn off the ec H2O system press the ec H2O switch located below the key switch Figure 65 ATTENTION During first time use and after replaci...

Страница 24: ...ec H2O scrubbing press the solution flow button located on the ec H2O module Figure 71 One LED low two LED s medium and three LED s high FIG 71 10 T300e model To adjust the solution flow rate when co...

Страница 25: ...and floor mounted fixtures such as pedestal sinks and other breakable items Keep the metal scrub head edge away to avoid possible damage Tile Cove FIG 74 9 When leaving the machine unattended remove t...

Страница 26: ...0e FOR SAFETY When servicing machine all repairs must be performed by trained personnel HOUR METER The hour meter records the number of hours the machine has been operated Use the hour meter to perfor...

Страница 27: ...cing machine stop on level surface turn off machine remove key and set parking brake if equipped 2 To drain remaining water from solution tank pull the solution hose from the accessory rail Figure 83...

Страница 28: ...d problem Contact service S S S 0x0601 Severe environment detergent pump wiring connector or control board problem Contact service S S S 0x0910 Propel circuit breaker tripped Disconnect battery and re...

Страница 29: ...ult Scrub control board comm fault ec H2O system comm fault Restart If fault code persists contact service ON BOARD BATTERY CHARGER SERVICE INDICATOR CODES LED Fault Code Flashing LCD Fault Code CAUSE...

Страница 30: ...0x0703 0x0712 ec H2O system breaker tripped ec H2O pump breaker tripped Reset circuit breaker If trip repeats contact service ecH2O indicator solid red 0x0716 0x0727 0x0741 0x0746 ec H2O pump shorted...

Страница 31: ...crub head skirt Check for damage and wear Weekly O 7 Battery cells Check electrolyte level O 6 Squeegee assembly drip trap reservoir Check clean 50 Hours O 2 Cylindrical brushes Rotate brushes Check f...

Страница 32: ...repairs must be performed by trained personnel AFTER DAILY USE 1 Drain and rinse out the recovery tank Figure 86 See DRAINING TANKS FIG 86 2 T300 models Remove the debris tray and empty Figure 87 FIG...

Страница 33: ...all purpose cleaner and damp cloth Figure 95 FIG 95 10 Cylindrical scrub head Remove and clean debris trough Figure 96 FIG 96 11 Severe environment option Refill the severe environment tank with a re...

Страница 34: ...spect and clean the seal on the recovery tank lid Figure 104 Replace seal if damaged FIG 104 AFTER EVERY 100 HOURS OF USE If machine is equipped with the optional battery watering system check the wat...

Страница 35: ...for a minimum of 15 minutes S Do not leave the batteries partially discharged for long period of time S Only charge the batteries in a well ventilated area to prevent gas build up Charge batteries in...

Страница 36: ...is not equipped with charger FOR SAFETY The use of incompatible battery chargers may damage battery packs and potentially cause a fire hazard IMPORTANT NOTICE The battery charger is set to charge the...

Страница 37: ...After charging batteries unplug the power supply cord and wrap cord around the cord hooks Figure 113 For models equipped with an off board charger always disconnect the AC power supply cord first befo...

Страница 38: ...nnenschein 80 150 AH The factory setting dial position 0 is pre programmed to accommodate the battery type supplied with new machine After the dial is changed from the factory setting it should not be...

Страница 39: ...n 1 Remove the squeegee assembly from the machine 2 Fully loosen the two outside knobs on squeegee assembly This will separate the spring loaded blade retainer from squeegee frame Figure 122 To loosen...

Страница 40: ...g cartridge Figure 126 Drain recovery tank before lifting tank FIG 126 3 Disconnect the two hose connectors from the top of the cartridge by pressing the gray collars inward and pulling the connectors...

Страница 41: ...teries before storing machine to prolong the life of the batteries Recharge batteries every 3 months 2 Drain and rinse recovery tank and solution tank 3 Store the machine in a dry area with squeegee a...

Страница 42: ...SERVICE INDICATOR CODES Faulty charger Replace charger Machine will not propel Drive Model Propel fault has been detected See SERVICE INDICATOR CODES Circuit breaker tripped Reset circuit breaker Fau...

Страница 43: ...ot completely closed Check lid for obstructions Defective seals on recovery tank lid Replaced seal Little or no solution flow Empty solution tank Refill solution tank Low solution flow rate set Increa...

Страница 44: ...ransporting 21 maximum Ramp incline for loading empty tanks 21 maximum Solution flow rate T300e 1 9 L min maximum Solution flow rate T300 Low 57 L min Med 1 3 L min High 1 9 L min ec H2O solution flow...

Страница 45: ...tanks 21 max Solution flow rate T300e 1 9 L min maximum Solution flow rate T300 Low 57 L min Med 1 3 L min High 1 9 L min ec H2O solution flow rate Low 45 L min Med 94 L min High 1 3 L min Brush motor...

Страница 46: ...SPECIFICATIONS 46 Tennant T300e T300 03 2015 MACHINE DIMENSIONS 1095 mm 772 mm SINGLE DISK MODEL 1302 mm 43 cm Model 1372 mm 50 cm Model 508 mm 43 cm Model 559 mm 50 cm Model...

Страница 47: ...SPECIFICATIONS Tennant T300e T300 03 2015 47 1095 mm 772 mm DUAL DISK MODEL 1314 mm 660 mm...

Страница 48: ...SPECIFICATIONS 48 Tennant T300e T300 03 2015 1095 mm 772 mm CYLINDRICAL BRUSH MODEL 1283 mm 635 mm...

Страница 49: ...SPECIFICATIONS Tennant T300e T300 03 2015 49 1095 mm 772 mm ORBITAL PAD MODEL 1245 mm 521 mm...

Страница 50: ...SPECIFICATIONS 50 Tennant T300e T300 03 2015...

Страница 51: ...elow 1 Park the machine on a level surface and turn the key to off O position 2 Press and hold the Down Pressure button while turning the key on Release button when the far right battery discharge ind...

Страница 52: ...e factory assigned supervisor login number or your saved personalized supervisor login number to access the operator home screen 2 Press the settings button located on the home screen Figure 136 FIG 1...

Страница 53: ...be any combination of numbers ranging from 3 to 8 digits long FIG 143 6 Now select the controls that the new user should have access to use Figure 144 Green represents unlocked controls and gray repr...

Страница 54: ...profiles Figure 149 For example to edit any user profile settings including the factory assigned default supervisor login number press the Edit Profile button FIG 149 To change the factory assigned de...

Страница 55: ...sired default user by pressing the Operator or Supervisor button Figure 154 FIG 154 d Select a pre assigned user profile In this example operator profile JOHN is selected Figure 155 Turn the key off t...

Отзывы: