ELECTRICAL INFORMATION

This appliance has been designed for dry vacuum cleaning only and must not be used 
to pick up any liquids.

WARNING:

  This vacuum cleaner must be earthed. It must NOT be permanently wired into the electrical 

supply.

WARNING:

  Do not use any type of extension lead or cord. This vacuum cleaner must only be plugged 

into a suitable wall mounted outlet socket.

WARNING:

  Do not unplug this vacuum cleaner from the electrical supply when the vacuum motor is 

running (except in case of emergency).

Cable & Plug

This vacuum cleaner is a Class I (Earthed) appliance and has 10 metres of 3 core mains cable. The supply 
cord should be regularly examined for signs of damage. If the supply cord is damaged, it must be replaced 
by the manufacturer, our service agent, if so appointed, or a similar qualifi ed and competent person in order 
to avoid a hazard. Please contact the manufacturer or our service agent for further information. The cable

 

is fi tted with a standard (non ATEX) approved plug suitable for your socket (13amp 3pin for UK 230V, 
16amp round pin for Europe 230V and 16amp yellow round pin for UK 110V). The fi tted plug is suitable 
for standard supply sockets that are situated outside the zoned area. If the supply socket is situated within 
the zoned area it should be ATEX approved. The plug on this appliance should be removed and changed for 
a plug that is ATEX approved. Make sure that the plug that has been removed is disposed of immediately 
so there is no chance of the plug being used. The replacement plug must be fi tted by a competent person 
following the fi tting instructions provided by the plug manufacturer. Please note the following:

1) 

Ensure that the lengths of wire to be fi tted inside the plug have been cut to the correct length and the 
end correctly prepared. When preparing the cable ends take care not to damage the outer sheath, or 
the insulation surrounding the inner conductors.

2) 

Connect the blue (NEUTRAL) wire to the terminal in the plug which is marked with the letter “N” 
or coloured black.

3) 

Connect the brown (LIVE) wire to the terminal in the plug which is marked with the letter “L” or 
coloured red.

4) 

Connect the green/yellow (EARTH) wire to the terminal in the plug which is marked with the letter 
“E” or coloured green.

5) 

Tighten all screws. Ensure that all conductor strands have entered into the terminal posts and that 
the mains lead is securely held in place by the cable clamp.

Motor

110 volt models are rated at 0.9kw in accordance with BSEN60335-2-69

230 volt models are rated at 1.0kw in accordance with BSEN 60335-2-69.

The motor used in this appliance is a non sparking electronically commutated brushless motor and consumes 
a maximum running current of 9 amps (230v models) and 13 amps (110v models). The electrical supply 
should be fi tted with a fuse/protective device suitable for the current demand.

The electronic control of the motor limits the starting current to the above values. The motor is thermally 
protected. There is a thermal switch to protect the windings in the motor and there is a thermal switch 
to protect the electronic control circuit board. If your vacuum cleaner cuts-out please refer to page 8 
“Loss of Suction and Thermal Switch”. The cut-out switches will automatically reset when the motor 
temperature drops.

Содержание KEVA 20

Страница 1: ...TEX ELECTRIC VACUUM CLEANER OPERATOR MANUAL Clemas Co Unit 5 Ashchurch Business Centre Alexandra Way Tewkesbury Gloucestershire GL20 8NB Tel 01684 850777 Fax 01684 850707 Email info clemas co uk Web w...

Страница 2: ...6 Commissioning Your KEVA Vacuum Cleaner 6 Risk Assessment ATEX 6 Operating Instructions 7 Filtration System 7 Loss of Suction and Thermal Switch 8 Servicing Spares 8 Guarantee 8 Rating Plate 9 KEVA...

Страница 3: ...fined as non radioactive non explosive dusts that are hazardous to health if inhaled ingested or if in contact with the skin A hazardous dust can be defined as very toxic harmful corrosive or irritant...

Страница 4: ...n this vacuum cleaner is not designed to be emptied If it is full or if the vacuum efficiency is impaired it must be replaced 18 Do not use the appliance with any of the filters and or disposable Micr...

Страница 5: ...e fitted by a competent person following the fitting instructions provided by the plug manufacturer Please note the following 1 Ensure that the lengths of wire to be fitted inside the plug have been c...

Страница 6: ...for your outlet socket 4 Make sure that the electrical supply requirements on the rating plate are in accordance with your electrical supply 5 Conduct a risk assessment to ensure that this vacuum cle...

Страница 7: ...ed with a moulded plastic flange and sealing cap They are fitted over the inlet inside the canister and the dust debris is collected inside the bag The sealing cap is designed to prevent the escape of...

Страница 8: ...HEPA cartridges as damage to the pleated element and or seals will affect the performance and may cause a leakage through the filter of unfiltered air If the thermal switch activates to protect the mo...

Страница 9: ...ble for use in a potentially explosive dust and or gas atmosphere 6 II equipment group II surface industries 7 3 Category 3 product 8 D explosive dust atmosphere Zone 22 9 c constructional safety conc...

Отзывы: