background image

2123b_1_5_en_ bedingt.fm, 03.07.2014

P2122BA/EN 2014-06

7

Safety

1

1.4

Personal protective equipment

Wear protective goggles to protect against sprays of metal splinters and fluids.

Wear gloves to protect against skin irritation in case of direct contact with oil.

Danger of injury by being wound up in and caught by machinery

Wear a hairnet.

Wear close-fitting clothing.

Do not wear jewelry.

Sound level in the area of the user >  80 dB(A), danger of hearing damage 

Wear hearing protection.

1.5

Designated use

The 35PTHH is designed exclusively for fastening and releasing threaded fasteners.

Do not use it as a hammer.

Do not open it or modify it structurally.

Do not use it in areas where there is a risk of explosion.

1.6

Noise and vibrations

  

With vibration levels ahv > 2.5 m², the exposure time is to be reduced. See example

Sound pressure level Lp in accordance with DIN EN ISO 15744

Idle / clockwise rotation for n 

 4,000 rpm

< 76 dB(A) 

Vibration values in accordance with DIN EN ISO 28927-2

Idle / clockwise rotation ahv for n 

 4,000 rpm

< 1.0 m/s² 

Pulses ahv 35PTHH

< 3.0 m/s²

Pulses ahv 35PTHHA

< 3.5 m/s²

Pulses ahv 3 absorber (on request)

< 2.5 m/s² 

V

ibration level ahv m/s²

Allowed daily exposure time (hrs.) 

Example

Not allowed

Allowed

Содержание 35PTHH

Страница 1: ...For additional product information visit our website at http www apexpowertools eu 35PTHH Pulse shut off nutsetter Instruction Manual P2122BA EN 2014 06 ...

Страница 2: ... or parts thereof or copied to another natural or machine readable language or to a data carrier whether electronic mechanical optical or otherwise without the express permission of Apex Tool Group Secondary information P2204BA Instruction Manual Oil filling unit In the text 35PTHH stands for all of the designs of the pulse shut off nutsetter described here identifies instructions to be followed i...

Страница 3: ...ir supply 9 4 2 Change air inlet top bottom only on 35PTHHA 10 4 3 Connect the tool 10 4 4 Setting up the tool 11 5 Troubleshooting 13 6 Maintenance 15 6 1 Service schedule 15 6 2 Fill reserve oil 16 6 3 Complete oil filling 18 7 Disassembly instructions 21 7 1 Remove motor unit 21 7 2 Remove throttle valve 23 7 3 Remove pulse unit 24 8 Assembly instructions 24 8 1 Install motor unit 24 8 2 Instal...

Страница 4: ...4 P2122BA EN 2014 06 P2122BA EN_2014 06_35PTHHIVZ fm 03 07 2014 10 2 Dimensions 35PTHHA in mm 40 10 3 Performance Data 40 10 4 Ambient conditions 41 11 Service 41 12 Disposal 41 ...

Страница 5: ...scribes the type of danger WARNING Potentially hazardous situation for health and safety If this warning is not observed death or serious injury may occur CAUTION Potentially hazardous situation to health and safety or risk of material and environmental damage If this warning is not observed injuries or damage to materials or the environmental could occur NOTE General notes include application tip...

Страница 6: ...ed in the lower air inlet If you hear unusual noises or vibrations switch off the tool immediately Cut off the air supply immediately Before carrying out repairs adjusting the torque or replacing screw bits disconnect the tool from the compressed air line The compressed air line must be depressurized before disconnecting it Never use the air hose to hold raise or lower the tool Air hoses the suspe...

Страница 7: ...35PTHH is designed exclusively for fastening and releasing threaded fasteners Do not use it as a hammer Do not open it or modify it structurally Do not use it in areas where there is a risk of explosion 1 6 Noise and vibrations With vibration levels ahv 2 5 m the exposure time is to be reduced See example Sound pressure level Lp in accordance with DIN EN ISO 15744 Idle clockwise rotation for n 4 0...

Страница 8: ...n supplied 1 35PTHH 1 This instruction manual 1 Declaration of Conformity 1 Hex wrench WAF 2 3 Product description 3 1 Operation and functional elements Item Designation 1 Reverse switch 2 Torque adjustment see Abb 4 1 page 11 3 Pulse count settings see 4 4 2 Change pulse count page 12 4 Air inlet 4 1 5 3 6 8 7 9 2 8 Alternative position 2 5 4 35PTHH 35PTHHA ...

Страница 9: ...filters regulators lubricators should be installed 5 Connection for evaluation electronics TVP100 6 Start button 7 Reserve oil adjustment see 6 2 Fill reserve oil page 16 8 Suspension bail 9 Hex wrench WAF 2 order no 935490 Order no 934918 Signal connection kit for evaluation elec tronics TVP100 Protective sleeve Order No 937448PT 35PTHH Order No 937443PT 35PTHHA Vibration absorber Order No 935965...

Страница 10: ...rench WAF 17 Activate compressed air 620 kPa in anticlockwise rotation Regulator To attain constant work results the working pressure must be kept constant for every individual tool Lubricator Compressed air requires a small amount of oil and is orientated to the air consumption of the tool Calculate the time T between two drops of oil and make the following settings at the lubricator F Factor for...

Страница 11: ... drive Clockwise rotation 4 000 500 rpm Anticlockwise rotation 6 500 500 rpm CAUTION Danger of injury from unintended startup Shut off the compressed air before adjusting the torque CAUTION Danger of injury from rotating hex wrench Adjust the torque using the provided hex wrench only Never use an angular wrench Settings example Tightening 25 Nm Screw M8 8 8 Approximately 3 turns of the torque adju...

Страница 12: ... Measuring the torque page 13 7 In case of deviations correct the torque setting and 8 Repeat the rundown Requirement Measure High shut off accuracy especially with hard screwed joints Increase number of pulses per tighten ing Recommended number of pulses 6 Reduce the speed 1 Unscrew the threaded pin using the hex wrench WAF 2 2 Turn exhaust air throttle clock wise Shortening the rundown time part...

Страница 13: ...h 5 m Increase the working pressure Reverse button is not at the detent Turn the reverse button to the detent Excessive transmission damping due to extension and worn socket Use a shorter or more rigid exten sion Replace the socket Insufficient oil in the pulse unit no pulse build up See 6 2 Fill reserve oil page 16 If X 0 see picture 2 the reserve oil is exhausted and must be refilled to guarante...

Страница 14: ...14 P2122BA EN 2014 06 2123b_1_5_en_ bedingt fm 03 07 2014 Troubleshooting 5 Empty side ...

Страница 15: ...activation before service disconnect the tool from the compressed air supply Maintenance interval Rundowns Measures W1 100 000 Check the suspension bail for functional safety Check the air hose for wear Check the square on the output drive for wear Check the air inlet for tight fit Check the housing of the pulse unit for tight fit Check the maximum idling speed Check the reserve oil W2 500 000 Oil...

Страница 16: ...out the maintenance measures marked W2 after an operating time of 200 days 6 2 Fill reserve oil If X 0 see picture 2 the reserve oil is exhausted and must be refilled to guarantee a controlled process Factor Value assumed in 6 1 Maintenance plan Description V V1 100 000 V2 500 000 V3 1 000 000 Number of rundowns after which a maintenance measure is pre scribed by Apex Tool Group T1 1 8 seconds Spe...

Страница 17: ...internal equalization hole is opened 4 To avoid air pockets fill the filling hole full of oil 5 Position the injector so that it has a sealing effect and add reserve oil until distance X for spacer B2 is present Maintain distance X and secure with B2 Refit set bolt and ball Remove B2 B1 B2 Approx 5 ml X approx 2 5 mm ...

Страница 18: ...icture internal equalization hole is opened 3 Use adapter to connect pulse unit to the quick disconnect coupling Close shutoff valve 4 Set the working pressure to approx 500 kPa Slowly open the shut off valve all the way until the gauge shows a negative pressure of 10 mbar 1 bar Wait approx 2 minutes until the number of vac uum bubbles has reduced significantly Slowly close the shut off valve The ...

Страница 19: ...serve oil until distance X for spacer B2 is achieved Maintain distance X and secure with B2 Refit set bolt and ball Remove B2 Small air bubbles that become visible due to the high pressure during filling do not mean that the pulse unit is leaking The filling process is not impaired If a flow of large rapid bubbles appear and continue to be produced and the pressure drops there is a leak inside of ...

Страница 20: ...20 P2122BA EN 2014 06 2123c_Wartung_en_bedingt fm 03 07 2014 Maintenance 6 Empty side ...

Страница 21: ... fm 03 07 2014 P2122BA EN 2014 06 21 Disassembly instructions 7 7 Disassembly instructions Please refer to 9 Spare parts page 29 und 9 5 Equipment order list page 38 7 1 Remove motor unit 7 1 1 Remove actuating ring 1 2 1 2 3 4 ...

Страница 22: ...22 P2122BA EN 2014 06 2123d_Reparatur_en_bedingt fm 03 07 2014 Disassembly instructions 7 7 1 2 Remove shut off 1 2 3 4 5 6 ...

Страница 23: ...aratur_en_bedingt fm 03 07 2014 P2122BA EN 2014 06 23 Disassembly instructions 7 7 2 Remove throttle valve Changing blades Changing bearings rotor 1 2 Spring force 3 C3 C2 C1 61 59 56 55 60 C3 C1 59 54 55 SW 3 8 ...

Страница 24: ...otective goggles NOTE Permitted only if filling is guaranteed with oil filling device see 6 2 Fill reserve oil page 16 Pulse unit must have cooled down to room temperature CAUTION Only perform installation in accordance with exploded drawing see 9 Spare parts page 29 Incorrect installation can lead to uncontrolled reactions e g unexpected start up or parts being hurled out Tighten all screwed join...

Страница 25: ...ions 8 8 1 1 Install rotor cover 1 Press 59 in with C4 see X 2 Examine Y with thickness gage If dimension Y step 1 with support C5 C6 C7 repeat Press 61 in with C8 C8 59 C4 C5 C6 C7 X 54 55 X Base 0 02 C4 0 03 C5 0 04 C6 0 05 C7 Thickness gauge 0 03 mm max 2 mm Y C8 C9 61 56 60 C8 ...

Страница 26: ...26 P2122BA EN 2014 06 2123d_Reparatur_en_bedingt fm 03 07 2014 Assembly instructions 8 8 1 2 Install shut off 1 2 3 4 5 6 7 8 ...

Страница 27: ...2123d_Reparatur_en_bedingt fm 03 07 2014 P2122BA EN 2014 06 27 Assembly instructions 8 8 1 3 Install actuating ring 1 2 3 4 5 6 ...

Страница 28: ...ions 8 8 2 Install pulse unit 8 2 1 Assembling the hydraulic blades NOTE To prevent damage lubricate the gaskets and O rings using grease order no 914392 before assembly 1 2 3 4 5 6 7 8 F1 93 F1 98 93 97 95 94 2 97 96 2 F1 93 91 F1 F2 Tightening torque 60 10 Nm WAF 1 2 D3 D2 D1 84 ...

Страница 29: ...ance and increased maintenance requirements If non original spare parts are installed the tool manufacturer is entitled to declare all warranty obligations for null and void We would be glad to prepare a special quote for you for spare and wear parts Please give the following data Tool model Number of tools Number of rundowns per day or per shift Shut off torque Fastening time per rundown ...

Страница 30: ...30 P2122BA EN 2014 06 2122e_Ersatzteile_en fm 03 07 2014 Spare parts 9 9 1 Pistol grip 35PTHH Adhesive order no 914860 Grease order no 914392 ...

Страница 31: ...2122e_Ersatzteile_en fm 03 07 2014 P2122BA EN 2014 06 31 Spare parts 9 1 Order no 2 Quantity 3 Part of motor service kit K1 order no 936252PT 4 Dimensions ...

Страница 32: ...32 P2122BA EN 2014 06 2122e_Ersatzteile_en fm 03 07 2014 Spare parts 9 9 2 Pistol grip 35PTHHA Adhesive order no 914860 Grease order no 914392 ...

Страница 33: ...2122e_Ersatzteile_en fm 03 07 2014 P2122BA EN 2014 06 33 Spare parts 9 1 Order no 2 Quantity 3 Part of motor service kit K1 order no 936252PT 4 Dimensions ...

Страница 34: ...34 P2122BA EN 2014 06 2122e_Ersatzteile_en fm 03 07 2014 Spare parts 9 9 3 Motor unit See 8 1 1 Install rotor cover page 25 See 8 1 2 Install shut off page 26 ...

Страница 35: ...2122e_Ersatzteile_en fm 03 07 2014 P2122BA EN 2014 06 35 Spare parts 9 1 Order no 2 Quantity 3 Part of motor service kit K1 order no 936252PT 4 Dimensions ...

Страница 36: ... 2122e_Ersatzteile_en fm 03 07 2014 Spare parts 9 9 4 Pulse unit Tightening torque see 8 2 Install pulse unit page 28 For disassembly note the position of the balls in the control disc Reassemble balls in the same position ...

Страница 37: ...s 9 1 Order no 2 Quantity 3 Part of hydraulic service kit K2 order no 936211 4 Dimensions see table on page 37 Order no 84 93 115 116 117 118 119 120 35PTHH403 35PTHHA403 3 8 936043 935410 35PTHH40Q 35PTHHA40Q 1 4 936044 935453 931789 917794 935477 935406 931793 931789 ...

Страница 38: ...38 P2122BA EN 2014 06 2122e_Ersatzteile_en fm 03 07 2014 Spare parts 9 9 5 Equipment order list 1 Order no ...

Страница 39: ...2122f_TechnDaten_en fm 03 07 2014 P2122BA EN 2014 06 39 Technical data 10 10 Technical data 10 1 Dimensions 35PTHH in mm Abb 10 1 ...

Страница 40: ...Performance Data Order no Recommended torque range Idling speed Air consumption Ft lbs Nm 8 8 lbs kg ft3 min m3 min min max rpm mm Idling Pulses 35PTHH403 35PTHHA403 3 8 14 8 20 25 8 35 Anticlockwise 6 500 Clockwise 4 000 M8 2 31 1 05 2 45 1 11 5 30 0 15 15 89 0 45 35PTHH40Q 35PTHHA40Q 1 4 2 31 1 05 2 45 1 11 ...

Страница 41: ...y 25 90 non condensing CAUTION Injuries and environmental damage from improper disposal The components and auxiliary materials of a machine incorporate risks to health and the environment Catch auxiliary materials oils greases when drained and dispose of them properly Separate the machine parts by material and dispose of them properly Separate the components of the packing and dispose of them by s...

Страница 42: ... 3238 3870 Fax 55 15 3238 3938 EUROPE MIDDLE EAST AFRICA ENGLAND Apex Tool Group GmbH C O Spline Gauges Piccadilly Tamworth Staffordshire B78 2ER United Kingdom Phone 44 1827 8727 71 Fax 44 1827 8741 28 GERMANY Apex Tool Group GmbH Industriestraße 1 73463 Westhausen Germany Phone 49 0 73 63 81 0 Fax 49 0 73 63 81 222 HUNGARY Apex Tool Group Hungária Kft Platánfa u 2 9027 Györ Hungary Phone 36 96 6...

Отзывы: