14
P1993BA/EN 2014-06
1994b_1_5_en-bedingt.fm, 12.06.2014
Before initial operation
4
Accuracy insufficient
Adapter parts
Replace adapter parts
Use extension and socket with
guide diameter
Pressure fluctuations in the air network
Use a pressure regulator
Premature release of the start button
Keep start button pressed until nut-
setter has stopped rotating
Fastening time too
long: > 4 seconds
Joint too soft; crush nuts, self-tapping
screws
Increase the speed
Use a pulse nutsetter with a higher
capacity.
Error
Possible causes
Measures and remedies