E.)  Installing the Signal Cable   

(Continued)

Page 7

5.) Make sure the wraps are flush against one another and not overlapping.

6.)  Once the wrapping is complete, secure the signal cable to the pipe using another
nylon cable tie.  Remove the excess cable tie.

7.)  Route the loose end of the signal cable back to the power unit.  Trim the cable to
length.

8.)  Carefully strip the outer plastic shield from the end of the signal cable, leaving about
¼" to 3/8" of bare cable.  Twist the bare cable and insert the end into the unused
receptacle post on the power unit.  Tighten the receptacle post.

F.)  Electrical Hookup / Activating the System

The unit you received will work on 115VAC or 230VAC,
however it does have a 110VAC plug on the end of it.  If
you need to convert it to 230VAC, you will need to
exchange the plug on the end.
Once everything has been installed, one green indicator
light should come on for power, and when the coil is
wrapped and connected properly, all the green LED lights
should come on and oscillate back and forth continu-
ously.
The unit is only properly installed and functioning when all the green lights are oscillat-
ing.  When only one green light (the far left side) comes on, that means the electrical is
hooked up, but the signal cable is not installed properly.

1166 Kapp Drive, Clearwater, FL, 33765

Phone: 800-756-7946 or 727-562-5186   Fax: 727-562-5187

clearwater-enviro.com

The best feature of ScaleBlaster is that there is no
maintenance required!  No heavy bags of salt to haul
around.  No batteries to replace or moving parts to repair!

Allow at least 90 days to realize the full effects!

  The

older your house, the longer it may take to fully descale
the pipes.  After a period of time, scale around sinks, taps
and showerheads will soften.  These deposits may
collect inside the faucet and head screens, leading to
temporary blockage. It is best to periodically clean these screens as needed during the
period of scale softening. This means the system is working!

We also strongly recommend that you drain your water heater after 90 days of install-
ing the ScaleBlaster.

  You will be surprised at what has accumulated over the years.

This will make your water heater more efficient.

Please note that the ScaleBlaster is not a water softener, but a water conditioner.

After this "break-in" phase, all we ask you to do is to check to make sure the two
indicator lights are on (is case of a power surge or failure).  The unit should stay on 24
hours a day.  It only uses a few dollars a year in electricity.

The unit comes with a full 10-year warranty and is designed to have a lifespan much
longer than that.

G.)  Enjoying the ScaleBlaster

TM

Содержание SB-150

Страница 1: ...s Page 2 The SB 150 ScaleBlaster unit should contain all the components listed below Mounting Brackets 4 Mounting Bracket Screws 4 Warranty Card 1 Nylon Zip Ties 3 Users Manual 1 B Tools and Materials Required Signal Cable 50 Drill Drill Bit s Screwdriver Screws andAnchors WireStripper Additional tools may be required for special installations that require electrical or plumb ing changes Control U...

Страница 2: ...an electrical source Wrap the coil in the middle of this section and as far away from the galvanized pipe as possible Clearwater Enviro Tech manufactures a model specifically for steel pipe the SBR 800 Contact your dealer for more informa tion Basic overview Type of Pipe CopperPipe PVC Pipe GalvanizedSteel Pipe Page 4 Location for the install 1 The most desirable place to wrap the signal coil is o...

Страница 3: ...o etc This should be within 5 feet of a power source and 15 feet of the location for the signal cable The surface should be flat The unit can be mounted in any direction and installed inside or outdoors 10 E Installing the Signal Cable 1 Insert the pre stripped end of the signal cable into one of the two signal terminals located on the bottom right side of the power box The recep tacle post can be...

Страница 4: ...ked up but the signal cable is not installed properly 1166 Kapp Drive Clearwater FL 33765 Phone 800 756 7946 or 727 562 5186 Fax 727 562 5187 clearwater enviro com The best feature of ScaleBlaster is that there is no maintenance required No heavy bags of salt to haul around No batteries to replace or moving parts to repair Allow at least 90 days to realize the full effects The older your house the...

Отзывы: