1.   Securely mount the system upright to a flat vertical surface within  
 

5 feet of the point of use below the normal median water level. 

     

NOTE:

 

The system must not be installed higher than 3 feet  

     above the bottom of the tank or basin

.

 

  

2.   Use 

¾

” tubing to fit between the unit and the tank.  Install 

      with  1” hose clamps on both ends to secure tubing. 

 

3.   To keep the pump from cavitating when the system is “off”, create 

a loop on the outlet side of the pump with a diameter of 
approximately 9 inches.  Connect a primer valve (customer 
supplied) in line for use when priming. (See Figure 2) 

 

 4. Supply main power to unit.

 

 

      120VAC 60Hz 

-

 

Plug main power outlet into a standard wall outlet. 

 

 

220VAC 50Hz

 

 

  - Hard wire the main power to the pigtailed main power 

 

    cord provided.  Wire color code; Brown=L1, Blue=Neutral,  

 

    Green/Yellow=Ground. 

 

 5.  Prime the pump by initiating water flow towards the pump.  Open 

the primer valve (See Figure 2) allowing water to flow to drain.  
Once there is flow across the pump initiate power by setting the 
timer. 

 

6.   FOR OLDER VERSIONS: To initiate operation, set the timer dial        

clockwise, matching the current time of day to the “TIME” arrow.  
Pull outwards on tabs to set the “ON” time of the system.  Each tab 
represents 30 minutes.  When power is on the light on the right side 
of the system will illuminate. 

FOR NEWER VERSIONS see page 5 

 

7.   Once power is “ON” and the pump is primed, close the primer 

valve.  Be sure that all valves down stream are open. 

 
8.   The Standard Cubic Feet per Hour (SCFH) Air Flow Meter should 

read between 5-8 SCFH, when in normal operation. 

 
 

Содержание Ozone Systems PRO400

Страница 1: ...n System ClearWater Tech LLC Integrated Ozone Systems 850 E Capitolio Way San Luis Obispo Ca 93401 805 549 9724 Fax 805 549 0306 E mail service cwtozone com www cwtozone com Copyright 2006 ClearWater Tech LLC Reproduction of any kind is prohibited LIT619 REV022416 ...

Страница 2: ...rWater Tech ozone generators represent potential dangers ozone gas and high voltage electricity OZONE GAS WARNING Low concentrations of ozone can cause irritation to the eyes throat and respiratory system HIGH VOLTAGE WARNING ClearWater Tech ozone generators operate at high voltages If contact is made with operating high voltage components electric shock will occur Compare the ozone system equipme...

Страница 3: ... draw the ozone into the water a 24 hour programmable timer and 0 400 grams per hour of Corona Discharge ozone generation This self contained system can be used for recirculation of drinking water storage tanks water features and residential spas STORAGE TANKS Up to 1500 gallons WATER FEATURES Up to 1000 gallons RESIDENTIAL SPAS Up to 1000 gallons with residual sanitizer NOTE Pre filtration is STR...

Страница 4: ... 50Hz Hard wire the main power to the pigtailed main power cord provided Wire color code Brown L1 Blue Neutral Green Yellow Ground 5 Prime the pump by initiating water flow towards the pump Open the primer valve See Figure 2 allowing water to flow to drain Once there is flow across the pump initiate power by setting the timer 6 FOR OLDER VERSIONS To initiate operation set the timer dial clockwise ...

Страница 5: ...FIGURE 1 FIGURE 2 customer supplied 4 ...

Страница 6: ...uence to complete up to eight ON OFF times as desired When programming is done press the CLOCK key then the SELECT key repeatedly until the indicator bar is above the word AUTO To Review Program Press TIMER key repeatedly When done press the CLOCK key to return to the time of day To Cancel Change Part of the Program Press TIMER key repeatedly until the particular ON or OFF time appears Set new ON ...

Страница 7: ... psi BATTERY Replace only with Lithium battery type CR2032 REPLACING THE BATTERY Battery should be available locally should it need to be replaced Disconnect the power to the unit and remove the front cover retaining screws and slide front cover off Than remove 3 screws to remove timer plate See figure1 page 4 To replace the battery open the battery compartment on back of timer plate and install n...

Страница 8: ...e RGA number must appear prominently on the exterior of the shipped box es The product and or part must be packaged either in its original packing material or in comparable and suitable packing material if the original is not available You are responsible for paying shipping charges to CWT and for any damages to the product and or part that may occur during shipment It is recommended that you insu...

Отзывы: