CLEARSPAN
™
STORAGE MASTER
34
PB02580R6N1D Revision date: 03.22.19
Install PolyCor™ Front End Wall
PolyCor™ is installed on the front end wall of the shelter. It is attached using FA4474 Tek screws and neo-bonded
washers. Consult the PolyCor™ Installation diagram in the Quick Start section to determine where the panels are seamed
and where to attach the panel to the end wall framing.
IMPORTANT:
Install the pedestrian door
before
installing the panels adjacent to and above the pedestrian door
opening.
Secure the pedestrian door to the end wall frame using 112234B #14 self-tapping screws included with the
hardware
. Install the door now if equipped.
The materials and parts needed to install the panels include:
• PolyCor™ panels and H-channel
• Tek screws and neo-bonded washers
Read the information below before you begin:
• Use FA4474 Tek screws and 102921 neo-bonded washers to secure the panels to the end frame.
• Install H-channel at each seam where panels meet.
• During preparation, rest the edges of the panels on cardboard or other material to protect them from dirt and damage.
• Consult the PolyCor™ Installation diagram in the Quick Start section for the location and lengths of the panels. (The
Quick Start section is located at the back of these instructions.)
The following steps describe one way to attach the panels. The quantity of the panels and the number of H-channel
pieces sent with the shelter is based on installing the panels in the pattern described below and as shown on the
diagrams.
ATTENTION:
Changing the pattern of the panel placement and the location of the seams may require the purchase of
additional panels and H-Channel.
Complete the following steps to install the PolyCor™ panels.
1. After installing the pedestrian door, attach the lower 4' x 8' section of PolyCor™ to the vertical frame members
(Panel X) using FA4474 Tek screws and washers evenly spaced (approximately 18" to 24").
ATTENTION:
The section of PolyCor™ marked with an Y in the above diagram is cut from a full 4' x 8' sheet.
Cut panels so that seams fall on the vertical end wall frame tubes. Consult the PolyCor™ Installation Diagram for
additional information.
The dash lines identify the
locations of H-channel. H-channel
is installed between all PolyCor™
panels.
Install H-channel on the panel
edges around the pedestrian
door to finish these edges.
DO NOT install H-channel
to the panel edges around
the large door opening.
Install FA4474 Tek screws and
washers around the outer edges
of the side and upper panels to
secure the panel to the rafter.
Tape over these fasteners to
protect the cover and cover
bonnet.
Y
H-Channel
Install the pedestrian door
before
installing the PolyCor™ panels
around the door.
X
ATTENTION:
When attaching the panels to the end
rafter, do not drive Tek screws through the strap used to
stretch the main cover from end-to-end.
Doing so will make it difficult to tighten these straps