background image

3

Revision date: 02.22.11

Side Profile Connection Details

When additional rafters are added to a standard building to change the rafter spacing from 6' on-center to 4' on-center, 

cable patterns may change 

for some building lengths

. The Side Profile diagrams in this guide show the cable patterns 

for buildings with 4' on-center rafter spacing. Use the diagrams for your building during the assembly.

REMEMBER:

 A standard building has 6' on-center rafter spacing. 

The diagrams in this guide show frames with 4' on-

center rafter spacing. This 110644 kit is not used when additional rafters are purchased to lengthen the original building. 

The diagrams on this page correspond to the details circled on the main Side Profile diagrams found on the remaining 

pages. 

Some details may not apply to some frame lengths. 

In some instances, the cable bracket shown in Detail A and 

Detail B is used to secure two (2) cables or four (4) cables. To secure two (2) cables, use two of the connection points on 

the 108874 bracket only. Actual angle of the cable runs may vary from the detail. Consult the Side Profile diagrams. 

Use the components contained in the 110644 adaptor kit sent with your building. This kit is used for all building widths 

and lengths. Some components may not be needed for your building. Consult the diagrams in this guide to determine 

what components of the kit are needed for your building when rafter spacing is 4' on-center.

ATTENTION:

 REPLACE 

THE ORIGINAL STRUT 

108872 WITH THE 

SHORTER 108871 

STRUT INCLUDED IN 

THIS ADAPTOR KIT.

108874

CABLE ASSEMBLY

CABLE ASSEMBLY

AS2167

(SHACKLE)

DETAIL D

RAFTER

CABLE ASSEMBLY

CABLE ASSEMBLY

AS2167

(SHACKLE)

EYE BOLT

 (108868)

LOCK WASHER

 (FAMA38B)

3/8" HEX NUT

 (FALB04B)

DETAIL C

DETAIL B

DETAIL A

108874

FAME08B

(3/8” FLAT WASHER)

108503

(CABLE BRACKET)

Adaptor Kit #110644 contains these parts:

108874

Double Roll Form Cable Connection Plate

2

108868

3/8" Cable Eye Bolt (welded shut)

1

FAME08B

3/8" flat washer (zinc)

1

FALB04B

3/8"-16 nut (zinc)

1

FAMA38B

3/8" lock washer (zinc)

1

108503

1/8" steel cable bracket (135 degree)

1

108871

7' Strut 1.66 14g single punch (82")

4

Содержание R020B00000F

Страница 1: ...ClearSpan All Rights Reserved Reproduction is prohibited without permission STK DESCRIPTION R020B00000F Rafter Kit for 20 Wide ClearSpan 20 Wide Rafter Kit with Mounting Feet Photo may show a building of a different length and width ...

Страница 2: ...nting hole as shown when connecting the rafter segments during the rafter assembly steps Insert above right shows the incorrect position of the rafter segment INCORRECT POSITION Lower end of each rafter segment includes purlin mounting holes DO NOT CONNECT THE LOWER END TO THE CHEVRON Upper End Upper ends do not include purlin mounting holes and are positioned at the top of the rafter assembly and...

Страница 3: ...les use two of the connection points on the 108874 bracket only Actual angle of the cable runs may vary from the detail Consult the Side Profile diagrams Use the components contained in the 110644 adaptor kit sent with your building This kit is used for all building widths and lengths Some components may not be needed for your building Consult the diagrams in this guide to determine what component...

Страница 4: ... Purlins ATTENTION Cable pattern is the same for paneled greenhouse frames where the purlins run on top of the rafters Sample frame shows the purlins attached to the underside of the rafters Your frame may differ Use these parts from the 110644 adaptor kit for your 20 x 36 building 108868 See Detail C 3 8 Cable Eye Bolt welded shut 1 FAMA38B See Detail C 3 8 lock washer zinc 1 FALB04B See Detail C...

Страница 5: ...5 Revision date 02 22 11 Customer Notes ...

Отзывы: