9
CLEARSPAN
™
POLY BUILDINGS
Revision date: 05.19.09
RAFTER ASSEMBLY (CONTINUED)
View below shows how to position all end clamps to
prepare for the frame assembly. Purlin pipe shown is
installed during the frame assembly procedure.
3. Repeat the same procedure for the final end rafter.
4. Continue with the ATTACH RAFTER FEET instructions
that follow.
Toward the inside
of the frame when
assembled.
#102857
End Rafter
Purlin
Space below is reserved for customer notes.
ATTACH RAFTER FEET
After assembling the rafters, attach two (2) rafter feet to
each rafter.
NOTE:
Skip this section if you have first spaced and
secured the rafter feet to the pony wall. Continue with the
frame assembly. Adapt those steps as needed to account
for any changes resulting from first attaching the feet.
1. Attach one rafter foot (104302) to a rafter using the 3/8"
hex head bolt (FAG363) and nut (FALB04B).
Bolt head to the
outside of the
shelter.
104302
Rafter Foot
FAG363
Bolt
FALB04B
Nut
2. Repeat step to attach the remaining rafter foot.
3. Repeat the above procedure for all rafter assemblies.
4. Continue with the FRAME ASSEMBLY instructions that
follow.