background image

11

FieldSmart

®

 Fiber Distribution Point (FDP)

SCD Indoor/Outdoor Wall Box 

________________________________________________________

Installation Manual

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected] 

Manual 019477 REV A - Jan 2018

Cleaning an MPO/MTP Connector

Female Connector

•  Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen and 

apply small amount of precision cleaner (about 1” in diameter) with  

Electro-Wash MX pen on to one end of the wipe. (

Figure 1)

Figure 1

Figure 2

Figure 3

• 

Hold end face at a 90 degree angle. For APC connection, adjust by  

slightly tilting the container or end face. Angle is correct when no drag is 

felt on the end face. (

Figure 2)

Male Connector

• 

Lightly moisten one side of the fiber optic swab (CC505F) by spotting a 

small amount (about 1”) of Electro-Wash PX or Electro-Wash MX pen 

onto the QbE. Hold the swab, 1 side down to the wetted area and hold 

for a count of 1-2-3-4-5.

•  Place swab, wet side down, at one end of connector end face and draw 

across in a diagonal sweep; i.e., from fiber 1 up and across to fiber 12. 

Turn swab over to dry and draw back from fiber 12 to fiber 1. (

Figure 3)

Содержание FieldSmart SCD

Страница 1: ...FieldSmart Fiber Distribtion Point FDP SCD Indoor Outdoor Wall Box Installation Manual _____________________________________________________ Manual 019477 REV A Jan 2018 ...

Страница 2: ...__ Manual 019477 REV A Jan 2018 Table of Contents Application 3 Description 3 Technical Specifications 3 Optional Items 4 Overview for Indoor Outdoor Wall Box 4 Wall box Installation 5 Installing Sealcons 5 Installing U Mount for xPAK in FDP XWB1 6 Installing Universal Cassette Mount for FDP XWB2 7 Installing Cassettes in FDP XWB5 8 Connector Cleaning Procedure 9 Standard Warranty 12 Proprietary N...

Страница 3: ...71 cable nut grommet for 24 63 cable Cassette Universal Mounting Kit Box Strain relief fitting nut grommet for 24 63 Ideal for any small count fiber scenario the FieldSmart Small Count Delivery SCD Wall Box accepts up to two Clearview Cassettes providing up to 24 fibers in a discrete footprint or a single Clearview xPAK of 6 fibers in the smaller wall box without sacrificing fiber management The l...

Страница 4: ...___________________________________________________ Manual 019477 REV A Jan 2018 Optional Items Optional Accessory Kit P N FDP xAK1 includes 1 Strain relief fitting and nut sealcon 2 Strength member clamps Overview for Indoor Outdoor Wall Box 1 3 4 FDP XWB2 and FDP XWB1 1 Mounting Tabs top and bottom 2 Hinged Side 3 Secondary Security Lock Hole 4 Screws for Additional Security 2 ...

Страница 5: ...les can then be drilled at each mark Using appropriate fasteners for the material attach the panel to the surface Installing Sealcons Identify the location of the sealcon on both size boxes the sealcon locations have been pre marked on the inside of the box for easy identification There are two sealcon locations for each box Use a 1 drill bit step drill is preferred tool drill out the plastic area...

Страница 6: ...emove contents from plastic bag and carefully cut the different components from the main bracket There is an instruction card included with each U Mount bracket 1 2 Once removed screw the U Mount bracket and retaining clips into the wall box The location for this is located on the back of the instruction card 3 You are now ready to install the xPAK into the wall box See Clearview xPAK install manu...

Страница 7: ...rd included with each U Mount bracket P N 012700 1 2 Assemble U Mount Bracket per instruction card Once assembled screw the U Mount bracket and retaining clips into the wall box Location for this is on the back of the instruction card Figure 1 You are now ready to install cassettes into wall box using the thumb screws to fasten the cassettes to the clear brackets Figure 2 See Cassette installation...

Страница 8: ... to 4 Clearview Blue Cassettes can be installed and buffer tube slack can be routed around the outside of the radius limiters on the plate The wall box will arrive as shown with the plate installed in the box Twist the threaded rods into the two lower pems on the sides of the plate These rods will be included as a ship along item 1 2 Insert the threaded rods through the holes in the sides of the c...

Страница 9: ...lead to scratching of the end face Learn the process of cleaning properly Note It is NOT recommended to use isopropyl alcohol to clean the end face Cleaning an SC LC Connector Cleaning the End Face Place one wiping paper on QbE 2 FiberSafe Cleaning Platen Figure 1 Apply small amount of precision cleaner about 1 in diameter with Electro Wash MX pen on to one end of the wipe Figure 2 Hold end face a...

Страница 10: ...rough an Adapter AND the Adapter Itself Lightly moisten the fiber optic swab 2 5mm 38542F or 1 25mm 38040 by spotting a small amount about 1 of Electro Wash PX or Electro Wash MX pen onto the QbE Hold the tip of the swab onto the wetted area and hold for a count of 1 2 3 4 5 Insert the swab into the adapter to the connector press lightly against the connector twist 2 3 times remove and discard Dry...

Страница 11: ...end of the wipe Figure 1 Figure 1 Figure 2 Figure 3 Hold end face at a 90 degree angle For APC connection adjust by slightly tilting the container or end face Angle is correct when no drag is felt on the end face Figure 2 Male Connector Lightly moisten one side of the fiber optic swab CC505F by spotting a small amount about 1 of Electro Wash PX or Electro Wash MX pen onto the QbE Hold the swab 1 s...

Страница 12: ...lacement at the option of Clearfield Inc shall constitute the exclusive sole remedy for a breach of this limited warranty Clearfield shall not be liable under any circumstances for any special consequential incidental punitive or exemplary damages arising out of or in any way connected with the product or with agreement to sell product to buyer including but not limited to damages for lost profits...

Страница 13: ...stall the equipment supplied Every effort has been made to keep the information contained in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification Technical Support Clearfield Inc can be contacted for any issues that arise with the supplied product...

Отзывы: