6.3 Waste fluid tank
The waste fluid tank has a capacity of 0.75 liter, which should allow 100 records to be cleaned before it
needs emptying. Of course this depends on the amount of fluid used for each cleaning.
If you clean more than 20 records in one day you should also empty the waste fluid tank at the end of
that day.
6.4 Draining and cleaning of the waste fluid tank
Draining the waste fluid tank
Place a suitable container on the floor for the waste fluid. Remove the cap from the rubber tube at the
rear of the machine and place the tube into the disposal container. Tilt the machine towards the back
(about 45°) until the fluid drains out of the tube.
Attention!
The rubber tube should only be opened for fluid release! When finished, always securely
reseal the tube with the cap!
Do not reuse the used fluid!
Cleaning the waste fluid tank
Remove the upper cleaning arm and pour cleaning fluid into the stainless steel tube.
A mixture of water and vinegar works well.
Attention!
During the cleaning process, never switch on the vacuum!
Let the fluid rest in the tank for about 20 minutes then drain as explained above.
Pic. 13 Rubber tube seal
Draining the cleaning fluid reservoir
If your
Double Matrix Professional ever needs to be transported make sure that there is no fluid left in
it.
It may be necessary to empty both the waste fluid tank and cleaning fluid reservoir.
Pull off the two rubber tubes from the cleaning arms and place them into a suitable container. Push the
‘LIQUID’ button to pump the fluid into the container until there is no fluid left.
Push the rubber tubes back onto the cleaning arms.
If you do not use the machine for a long period we recommend draining both the waste
fluid tank and cleaning fluid reservoir and disconnect it from the mains.