Safty instructions                                                                                           

 

 

The applicable VDE regulations must be observed for all devices that require an electrical  voltage for 
their operation. The VDE directives VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 are 
particularly relevant for this product. Please also observe the following safety instructions:

 

 

• 

Do not continue to use the Andino Gateway if it is damaged. 

 

• 

Assemblies and components do not belong in children´s hands!

 

• 

Devices that are operated with a supply voltage greater than 24 V may only be connected by a qualified 
person. The 230 V version of the Andino gateway may only be connected to the mains voltage by a 
qualified electrician.

 

• 

Use only approved and suitable antennas.

 

• 

Never operate the device without an antenna. It will be damaged.

 

• 

The electromagnetic radiation emitted by this device complies with the legal requirements. However, 
avoid prolonged direct contact with the antenna while the device is in operation.

 

• 

When handling products that come into contact with electrical voltage, the applicable VDE regulations 
must be observed.

 

• 

In commercial facilities, the accident prevention regulations of the German Federation of Institutions for 
Statutory Accident Insurance and Prevention (Verband der gewerblichen Berufsgenossenschaften) for 
electrical systems and equipment must be observed.

 

• 

Components, assemblies or devices may only be put into operation if they have previously been installed 
in a housing in such a way that they are safe to touch. They must be disconnected from the power 
supply during installation.

 

• 

Do not drop the product or subject it to strong mechanical pressure, as the effects may damage it.

 

• 

The device must be protected from moisture, splash water and heat exposure.

 

• 

Ensure sufficient air circulation during operation and avoid ambient temperatures of more than 50°C.

 

• 

Do not operate the device in an environment where flammable gases, vapors or dust are present.

 

• 

In schools, training facilities, hobby and do-it-yourself workshops, the operation of assemblies must be 
responsibly supervised by trained personnel.

 

• 

If the unit needs to be repaired, only original spare parts may be used! The use of deviating spare parts 
can lead to serious damage to property and personal injury! Repair of the device may only be carried out 
by a qualified electrician!!

 

• 

This appliance is not intended to be used by persons (including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and/or knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible for their safety.

 

                                                                                         

 

 

  Further information 

 

More information, application examples, frequently asked questions (FAQ) can be found on the product 
page: 

https://andino.systems/andino-gateway/andino-gateway-raspberry-pi-router-board

 

Содержание Andino

Страница 1: ...erating instructions are part of the product It contains important information on commissioning and operation Pay attention to this even if you pass the product on to third parties Therefore keep thes...

Страница 2: ...tents 2 Safty instructions 3 Further information 3 Product description 4 Intended use 4 Overview and schematic structure 5 Technical data 6 Radio parameters 4G Modem SIMCOM 7600E 6 Tested according to...

Страница 3: ...Berufsgenossenschaften for electrical systems and equipment must be observed Components assemblies or devices may only be put into operation if they have previously been installed in a housing in such...

Страница 4: ...ture monitoring DS1820 Intended use The Andino gateway is designed for mounting in electrical distribution boards The device can be operated with 24V or 85V AC 230V AC For operation with 24 volt DC vo...

Страница 5: ...or with EMC protection circuit and polarity reversal protection Power secondary 5 Volt max 2 5 Amps Digital inputs Galvanically isolated inputs for 24 volts Isolated up to 5 kV Digital outputs Relay o...

Страница 6: ...X 925 960MHz RX GSM1800 1710 1785MHz TX 1805 1880MHz RX WCDMA Band1 1920 1980MHz TX 2110 2170MHz RX Band8 880 915MHz TX 925 960MHz RX LTE Band1 1920 1980MHz TX 2110 2170MHz RX Band3 1710 1785MHz TX 18...

Страница 7: ...lectromagnetic field DIN EN 61000 4 3 2006 A1 2008 A2 2010 according to VDE 0847 part 4 3 of 04 2011 Immunity Burst DIN EN 61000 4 4 2012 according to VDE 0847 part 4 4 of 04 2013 Immunity Surge DIN E...

Страница 8: ...nual that must be followed Furthermore if there is danger to your health e g due to electric shock Disposal Electrical and electronic equipment that falls under the ElektroG law is marked with the adj...

Отзывы: