INSTALLATION INSTRUCTIONS:
1. Mount the Clear Comfort system near the surge pit to
minimize the length of blue Air Tubing.
2. Mount the Air Compressor near the Clear Comfort
system. Connect blue Air Tubing from the Compressor's
barb fitting to the bottom of the Clear Comfort system's
flowmeter (attached to the right side of the system)
and secure with hose clamps.
3. Thread the included Compressor Silencer/Filter into
the Air Compressor's open intake port.
4. Run Air Tubing from the Clear Comfort System into
the surge pit.
• If needed, core drill through concrete floor.
• If tubing needs to cross a floor, route Air Tubing
through grating or hatch and use conduit that is
secured to floor.
5. Connect the barb fitting(s) and Diffuser(s) to the PVC
Diffuser Manifold(s). Important:
Do not overtighten
diffuser, cracking of the PVC tee may occur.
6. Connect Air Tubing to the Diffuser
barb fitting(s) and secure
with clamp.
7. If installing a CCW300 or CCW500 system, connect the
included 1/4" splitter barb fitting to the Air Tubing at the
bottom of the surge pit.
Then, connect
Air Tubing from
the splitter to each
Diffuser and secure
each connection
with clamps.
8. In the surge pit,
position Diffuser(s)
near the location
that water enters the
pit and away from
the pump suction.
9. Mount the Junction Box on a wall. Insert the Clear Comfort
system cord into the Junction Box's open watertight strain
relief fitting and connect wires to the provided lever nuts:
green to green, black to black and white to white.
10. Plug in the Junction Box's power cord, press the Clear
Comfort system's power button ON and use the flowmeter's
adjustment knob to set the flow rate.
CLEAR COMFORT:
Quick Guide
Surge Pit Diffuser Installation
303.872.4477 [email protected] clearcomfort.com
©2021 Clear Comfort. All Rights Reserved. MADE IN USA
Air
Tubing
Clear Comfort
Commercial System
10
8
6
4
2
1 / min AIR
Air
Compressor
KIT CONTENTS:
Diffuser(s)
Air Compressor
Air Tubing
Junction Box
Compressor
Silencer/Filter