background image

303.872.4477        [email protected]        clearcomfort.com

22

BASIC WATER CARE

1.  Run Clear Comfort 24/7:

• To get proper airflow from the Clear 

   Comfort system, use a variable speed

   pump & set it between 2200 - 2400 RPM.  
• If you’re using a DE Filter, let it rest for 

   1 hour everyday 

2.  Balance Water 

3.  Chlorine Options 

4.  Shock As Needed

• Option 1: Cal-Hypo granules 

• Option 2: Liquid chlorine

• Option 3: Non-chlorine shock (not recommended for algae)

5.   Algae  Control 

• Use a proactive 90-day algae treatment

BASIC WATER CARE 

 • Polyquat Options:

     • poolife® ®  

     • GLB® Algimycin® 2000

     • POOL Breeze® Defender

   • Chelated Copper/Mineral Options:
       • poolife® AlgaeBan II 
       • poolife® Algaecide 90
       • POOL Breeze® Opticide® 
       • Pool RX
       • Nature2 Express

Содержание CCW100

Страница 1: ...t us 303 872 4477 support clearcomfort com clearcomfort com IMPORTANT SAFETY INSTRUCTIONS Clear Comfort s CCW100 Pool Spa System Patented Hydroxyl Based Advanced Oxidation AOP Installation Operations...

Страница 2: ...For the latest version please visit clearcomfort com ccw100 manual MADE IN USA 2020 Clear Comfort All Rights Reserved...

Страница 3: ...ation 8 Electrical Installation General 8 Electrical Installation Directly to Pump Circuit 9 Electrical Installation Wall Outlet 9 Cartridge Connection 10 INSTALLING THE CLEAR COMFORT MANIFOLD INJECTI...

Страница 4: ...charge within 90 days of the receipt of defective product barring unforeseen delays To obtain warranty replacements or repair defective components or parts should be returned transportation paid to th...

Страница 5: ...to minimize abuse from lawn mowers hedge trimmers and other equipment 7 For all cord and plug connected units WARNING To reduce the risk of electric shock replace damaged cord immediately 8 For units...

Страница 6: ...ather than hardwiring an appropriate 120V or 230V receptacle outlet and plug may be used to connect to the pump controlled circuit If the unit is being wired to standalone AC power i e not through the...

Страница 7: ...ately The Clear Comfort system protects pool or spa water biocide scale control and corrosion control without the harsh effects of salt chlorine high cyanuric acid or high chlorine levels The pool or...

Страница 8: ...of its life expectancy 8 000 hours and it s time to purchase a replacement cartridge To exchange your Cartridge Unit please visit clearcomfort com cartridge Red Light Cartridge Unit has reached its li...

Страница 9: ...ubing length should be as short as possible with no more than 10 feet from the system to the Manifold Venturi injection location Indoors or outdoors Either is suitable It is recommended to install awa...

Страница 10: ...nits are factory set to 230V If your system will be powered by 230V skip to Step 4 3 Set the switch on the ballast on the orange Control Unit Remove plug in the left side of the Control Unit With a sm...

Страница 11: ...red voltage See Figure 2 Ensure white marked saddle switch matches correct voltage 4 If hard wired cord supplied must be hard wired in accordance to the National Electrical Code and in accordance with...

Страница 12: ...with the arrow in Figure 3 Seat the Cable Connector down onto the Cartridge Connector and turn the Cable Connector s Collar a quarter turn clockwise to lock the Cable and Cartridge Connector together...

Страница 13: ...Injection NOTE For full system diagrams that include additional sanitation systems integrated with the Clear Comfort system see pages 18 and 19 FULL SYSTEM DIAGRAM MANIFOLD INJECTION NOTE The Manifold...

Страница 14: ...or proper water flow configuration position If retrofitting cut a 11 section of the main 2 Select Orientation The 3 way valve unions allow you to install the Manifold either left to right or right to...

Страница 15: ...pool plumbing 5 Position 3 Way Valve Position the 3 way valve handle in between the Venturi water out flow as highlighted in Figure 9 Make adjustments as necessary to set Venturi air suction to draw b...

Страница 16: ...rt com clearcomfort com 14 INSTALLING THE CLEAR COMFORT MANIFOLD INJECTION CONNECTING CLEAR COMFORT SYSTEM TO MANIFOLD VENTURI Figure 10 Venturi Connection Water Flow Figure 11 One Way Air Check Valve...

Страница 17: ...Tubing so that at some point tubing is above water level 3 Install 1 4 inch one way Air Check Valve supplied to eliminate any potential water back flow See Figure 10 and 11 for details 4 Gas exiting t...

Страница 18: ...ld and Check Valve 3 Connect blue Air Tubing to the Flow Meter 4 Adjust the Manifold s 3 way valve to increase decrease pressure until the Flow Meter reads 5 7 LPM Note If RPM on variable speed pump i...

Страница 19: ...Way Valve Position the 3 way valve handle in between the Venturi water out flow as highlighted in Figure 9 Make adjustments as necessary to set Venturi air suction to draw between 5 7 LPM using a Flo...

Страница 20: ...learcomfort com clearcomfort com 18 FULL SYSTEM INTEGRATION DIAGRAMS FULL SYSTEM DIAGRAM INLINE CHLORINE FEEDER Figure 16 Inline Chlorine Feeder FULL SYSTEM DIAGRAM OFFLINE CHLORINE FEEDER Figure 17 O...

Страница 21: ...pport clearcomfort com clearcomfort com 19 FULL SYSTEM DIAGRAM UV SYSTEM Figure 19 UV System FULL SYSTEM DIAGRAM SALT WATER CHLORINE GENERATOR Figure 18 Salt Water Chlorine Generator FULL SYSTEM INTEG...

Страница 22: ...bility purposes Clear Comfort provides a return shipping label so the Cartridge Unit can be properly recycled To exchange your Cartridge Unit please visit clearcomfort com cartridge 2 To remove the ca...

Страница 23: ...curely fasten the Cartridge Unit to the Control Unit using the side keyed brackets 6 Reconnect the Air Tubing to bottom of the Cartridge Unit 7 Remove old Air Check Valve from Air Tubing and replace w...

Страница 24: ...st for 1 hour everyday 2 Balance Water 3 Chlorine Options 4 Shock As Needed Option 1 Cal Hypo granules Option 2 Liquid chlorine Option 3 Non chlorine shock not recommended for algae 5 Algae Control Us...

Страница 25: ...oduces an excellent biocide which kills bacteria protozoa and viruses How long does installation take Typically installation should take a few hours As soon as it is installed it is ready to start tre...

Страница 26: ...Wiring to a standalone electrical outlet use when pump continuously operates If the unit is being wired to standalone AC power i e not through the pump circuit on either 120V or 230V it should be ins...

Страница 27: ......

Страница 28: ...the latest version please visit clearcomfort com ccw100 manual For further assistance contact us 303 872 4477 support clearcomfort com clearcomfort com MADE IN USA 2020 Clear Comfort All Rights Reser...

Отзывы: