Problem:
Call signals do not function.
Cause 1:
Excessive DC loading of intercom line.
Solution 1:
Remove any audio transformers or other equipment which may be connected
across the intercom line. If equipment other than Clear-Com intercom equipment
must be connected to the intercom line, please contact Clear-Com application or
service personnel for advice.
Cause 2:
Far too many terminations on the intercom line.
Solution 2:
Check all Main Stations and Power Supplies to make sure each intercom channel
is terminated at only one point.
PARTS LISTS
Front Panel PCB Layout
Parts List for MS-232 Front Panel PCB and Chassis
Capacitors
Value
Type
Volts
Tol.
Part #
Designator
.1
uF
Monolithic
50V
10%
150035
C301
Resistors
Value
Power
Type
Tol.
Part #
Designator
4.7K
OHM
1/4
Carbon Film
5%
410013
R300
10K
OHM
1/4
Carbon Film
5%
410016
R312 R313
36K
OHM
1/4
Carbon Film
5%
410163
R303
Diodes and Transistors
Device
Description
Part #
Designator
LED
RED, ROUND, FLAT TOP LED
390044
LED301 LED303
LED
GREEN, ROUND, FLAT TOP LED
390045
LED302 LED300 LED304
Diode
1N4148 SIGNAL 10MA 75PIV
480000
D301
Miscellaneous
Device
Description
Part #
Designator
Button
FLAT TOP GREY KEYCAP
240064
S300 S301
Button
ROUND MINIATURE
240081
S304 S305 S311
Button
RECT. MINIATURE
240082
S306 S307
Knob
GREY INSERT 6X4.5MM HOLE .45DIA
240089
R306 R307 R308
Assembly
65 W 30 V SWITCHING POWER SUP.
400013
Relay
SPDT 24V MINI PC RELAY
450004
K301
Pot
50K TRIM POT H MTG.
470018
R309 R310
Pot
5K TRIMPOT H MTG.
470063
R304 R305
Pot
50K 25MM FLATTED SHAFT
470070
R306 R307 R308
Switch
DPDT SLIDE SWITCH
510090
S302 S303 S308
Switch
PUSH BUTTON SWITCH W/32V LAMP
510104
S300 S301
Clear-Com MS-232 Two-Channel Main Station
11
Содержание MS-232
Страница 13: ......