Clear-Com Encore AX-704 Скачать руководство пользователя страница 7

P I C - 4 7 0 4 ,   M A - 7 0 4   &   A X - 7 0 4   I F B   S Y S T E M

1 - 1

OPERATION

INTRODUCTION

During the production of a program for transmission or recording, a director or 
producer frequently needs to cue the performing talent. This is done using 
Interrupt FoldBack (IFB), a type of closed-circuit intercom for sending program 
and cue audio on “IFB” lines for the talent to monitor. The IFB line carries three 
signals: program audio, cue audio, and the dip or mute control. See the signal 
flow diagram below (Figure 1-1). Electronic control allows the director to 
interrupt the program signal when addressing the talent. IFB communications 
are one-way only from an access location to the selected talent position. 

Figure 1-1: Audio Control Paths

Clear-Com’s new stand-alone IFB components provide high performance, 
cost-effective answers for applications where regular intercom functions are not 
also required, or where space contraints require compact, versatile packaging. 
The simplest stand-alone system consists of a PIC-4704, an MA-704, a PS-702 
for power, and one to four TR-50 talent receivers. This system will permit cuing 
of one to four talent positions from only one access location. 

Note: Throughout this manual, “access location” refers to the physical place 

someone needs to cue the talent from. “Talent position” refers to the 
individual “talent” cue channels. 

DESCRIPTION

Clear-Com’s stand-alone series of IFB components offers two types of talent 
access station. The MA-704 has a socket for a gooseneck microphone and a 
pre-amplifier with line-level output. It provides access to four talent positions. 
Each AX-704 allows access, from the same location, to an additional group of 
four talent positions; it requires an external line-level signal for its cue audio 
source. The MA-704’s cue audio and ALL control signals will feed up to 24 
AX-704s, so that only one MA-704 is required at each 

access

 location. Each talent 

position may be accessed independently, or simultaneously with any other(s). 
The ALL button on the MA-704 simultaneously accesses all talent positions of 
the MA-704 and each AX-704 extension unit fed from that MA-704. 

1

Содержание Encore AX-704

Страница 1: ...PIC 4704 MA 704 AX 704 IFB SYSTEM I N S T R U C T I O N M A N U A L CLEAR COM ENCORE...

Страница 2: ...lameda CA 94501 U S A Vitec Group Communications 7400 Beach Drive Cambridge Research Park Cambridgeshire United Kingdom CB25 9TP Vitec Group Communications Room 1806 Hua Bin Building No 8 Yong An Dong...

Страница 3: ...nterconnect Cabling 2 5 System Connection 2 6 Physical Mounting 2 8 Setup and System Check 2 10 MAINTENANCE 3 1 Troubleshooting Tips 3 2 SPECIFICATIONS 4 1 PIC 4704 AX 704 and MA 704 Technical Specifi...

Страница 4: ...P I C 4 7 0 4 M A 7 0 4 A X 7 0 4 I F B S Y S T E M i i...

Страница 5: ...atus combination to avoid injury from tip over 11 Unplug this apparatus during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified service personnel Servicing...

Страница 6: ...ith the requirement of Electromagnetic Compatibility Directive 2004 108 EC and Low Voltage Directive 2006 95 EC This device complies with Part 15 of the FCC Rules Operation is subject to the following...

Страница 7: ...mplest stand alone system consists of a PIC 4704 an MA 704 a PS 702 for power and one to four TR 50 talent receivers This system will permit cuing of one to four talent positions from only one access...

Страница 8: ...s for each talent position and also terminates the IFB lines Figure 1 3 PIC 4704 Controls and Connectors The PIC 4704 controls and connectors shown in Figure 1 3 are 1 Program input level adjustment 2...

Страница 9: ...trol voltage on the IFB line causes the PIC 4704 to dip the program feed to that channel so that the cues given are understandable At an optional split feed receiver the program is dipped only in the...

Страница 10: ...P I C 4 7 0 4 M A 7 0 4 A X 7 0 4 I F B S Y S T E M 1 4...

Страница 11: ...704s were to be added for the same cable run the voltage drop would be an unacceptable 18 volts Therefore the other set of access stations would have to be connected on separate cable run from the PI...

Страница 12: ...tem block diagrams shown below only the system in Figure 2 2 is connected using the hub method all other systems are shown connected via the daisy chain method Figure 2 1 One Access Location to up to...

Страница 13: ...P I C 4 7 0 4 M A 7 0 4 A X 7 0 4 I F B S Y S T E M 2 3 Figure 2 3 Three Access Locations to up to Four Talent Positions Figure 2 4 One Access Location to up to Eight Talent Positions...

Страница 14: ...P I C 4 7 0 4 M A 7 0 4 A X 7 0 4 I F B S Y S T E M 2 4 Figure 2 5 Two Access Locations to up to Eight Talent Positions Figure 2 6 Two Access Locations to up to Eight Talent Positions...

Страница 15: ...minimizes resistance buildup effects in long cable runs Clear Com has ready made cable in 25 50 and 100 foot lengths to fit your cabling and system architecture needs Figure 2 7 XLR6 Cable Wiring In...

Страница 16: ...pin 2 or 3 must be connected to the common point of the source The high side is connected to the other pin 2 or 3 5 Use standard multi pair shielded cables and two conductor shielded mic cables to int...

Страница 17: ...t Position 8 TR 50 Talent Position 6 Program Source TR 50 Talent Position 4 TR 50 Talent Position 3 TR 50 Talent Position 2 TR 50 Talent Position 1 AX 704 Talent Positions 6 8 MA 704 Talent Positions...

Страница 18: ...9 inch rack using the optional model CEP RK rack kit Refer to the diagrams below for mounting dimensions when installing in a desk or console There are no special constraints on relative positioning o...

Страница 19: ...P I C 4 7 0 4 M A 7 0 4 A X 7 0 4 I F B S Y S T E M 2 9 Figure 2 10 AX 704 Mounting Dimensions...

Страница 20: ...t be adjusted via the control on the Receiver for a comfortable cue audio level in the earpiece or headset while someone is cuing that talent position from one of the access locations The Program Inpu...

Страница 21: ...onnected across the IFB lines in a bridging configuration high impedance 3 Each IFB line is terminated by its associated PIC 4704 The termination is about 220 Ohms AC and approximately 5 000 Ohms DC 4...

Страница 22: ...Isolate and replace faulty module on affected line b Isolate and repair cable Access button remains lit in amber after being released IFB line not termintated Insure that station connections to PIC 47...

Страница 23: ...pedance 5K Frequency Response Panel Mic Talent MA 704 only 200 18KHz 3dB Program Input Talent 200 18KHz 3dB Extension Line Talent 200 18KHz 3dB Max Distortion Panel Mic Talent MA 704 only 0 5 Program...

Страница 24: ...04 IFB Input 1 XLR6F IFB Extension 1 XLR6M Extension Bus Out 1 jack External Line In 1 jack Mic Gain 1 Gain adjust Rear Panel Connectors and Controls AX 704 IFB Input 1 XLR6F IFB Extension 1 XLR6M Ext...

Страница 25: ...bs 78kg AX 704 1 35 lbs 61 kg Notice About Specifications While Clear Com makes every attempt to maintain the accuracy of the information contained in its product manuals that information is subject t...

Страница 26: ...P I C 4 7 0 4 M A 7 0 4 A X 7 0 4 I F B S Y S T E M 4 4...

Страница 27: ...s and spare parts have a limited warranty of one year UHF wireless IFB products have a limited warranty of one year UHF wireless intercom systems have a limited warranty of three years All other Clear...

Страница 28: ...ica Canada Mexico Caribbean US Military Tel 1 510 337 6600 Email customerservicesUS vitecgroup com Asia Pacific South America Tel 1 510 337 6600 Email customerservicesAPAC vitecgroup com VGC has the r...

Страница 29: ...CUSTOMER HEREUNDER SHALL NOT UNDER ANY CIRCUMSTANCES EXCEED THE COST OF REPAIRING OR REPLACING ANY PART S FOUND TO BE DEFECTIVE WITHIN THE WARRANTY PERIOD AS AFORESAID This warranty does not cover an...

Страница 30: ...W A R R A N T Y i v...

Отзывы: