ICS-22 Speaker Station | User Guide
Page 15
Figure 2-2 Internal adjustments and connections
Note:
The ON position of each option switch is toward the circuit board and the OFF
position is toward the front panel. The default position of the switches is the OFF
position.
2.5.1
Call alert tone level control (1)
This feature must be disabled by turning the control fully counter clockwise.
2.5.2
Option Switches (2)
The three option switches are set to the OFF position by the factory and should
not be changed.
2.5.3
Matrix Connector (3)
This eight-wire modular jack (RJ-45) provides an audio and data communications
link to the Matrix system.
2.5.4
Program-Input Connector (4)
A three-terminal, plug-on connector provides the program input to the panel.
Program is fed to the headset and speaker. The level to the speaker or headset is
controlled by the program-level control. The program-input connector accepts a
balanced or unbalanced line-level audio signal from -20 dBu to +10 dBu. If this
input is connected to the stage announce (SA) output of a main panel it can be
used as a paging input. Since the level of this input is independently adjustable
from the intercom audio volume, it can be used to override the intercom audio.
Note:
The Program Input can be set between -20 dBu to +10 dBu.
The pinout of this connector is as follows:
1
2
Call alert tone
level control
Option switches
Front panel