19
EN
4. Place the battery compartment cover back and
fi
x it in place with the screw.
If the device cannot be switched on even though the battery is fully charged, the batteries
in the handle may need to be replaced.
Assembly
1. Plug the handle (
1
) onto the top of the extension tube (
3
). It must engage audibly.
2. Plug the stem with the handle into the stem mount (
6
) on the main unit (
8
). It must
engage audibly.
To remove the stem or the handle, press the corresponding release buttons in each case
and pull out the respective part.
Attaching / Removing Mop Pads
1. Hold the main unit (
8
) upside down.
2. Attach one mop pad in each case to a cleaning foot (
10
) using the hook and loop
fastener.
3. To remove the mop pads, pull them off the cleaning feet.
Filling the Water Reservoir
PLEASE NOTE!
■
When the water reservoir is
fi
lled, the main unit must
not
be tilted, turned upside
down or laid or placed on its side. Water could escape!
1. Open the water reservoir cap (
11
) on the main unit (
8
).
2. Fill the water reservoir with water using the measuring cup (max. 150 ml).
3. Close the water reservoir cap.
Fixing the Stem
The stem can be
fi
xed at a prede
fi
ned angle using the locking mechanism (
7
). This
function is suitable for cleaning vertical surfaces such as wall tiles, windows, or such like.
1. Press the release button (
A
). The pin moves out of the
stem mount (
6
).
2. Tilt the stem downwards until the pin engages in the
recess (
C
). The stem is
fi
xed in place.
3. To release the stem, slide the locking device (
B
) upwards
until it engages. The pin disappears in the stem mount.
A
C
B