Troubleshooting
If the device does not work properly, check whether you are able to rectify the problem
yourself. If the problem cannot be solved with the steps listed, contact the customer
service department.
Do not attempt to repair an electrical device yourself!
Problem
Possible cause
Fix
The battery is not
charging up. The
control lamp (
8
)
does not light up
when the device
is connected to
the mains power.
The mains adapter is not inserted
correctly in the plug socket.
Correct the
fi
t of the mains
adapter.
The barrel connector is not
plugged in the charging socket (
4
)
of the device correctly.
Correct the connection be-
tween the charging socket (
4
)
and barrel connector.
The plug socket is defective.
Try another plug socket.
There is no mains voltage.
Check the fuse of the electri-
cal distributor (fuse box).
The device can-
not be started.
The battery of the device is too
weak.
Charge up the battery.
Technical Data
Article
number:
02080
ID of operating instructions:
Z 02080 M DS V1 0220 dk
Device
Model number:
WS-19
Power supply:
7.4 V (Li-ion battery, 2000 mAh)
Power:
30 W (max.)
Capacity of water tank:
max. 200 ml
Battery
Charge time
:
approx. 4 – 5 hours
Operating
time:
approx. 30 – 40 minutes
(when the battery is fully charged)
Mains adapter
Model
number:
CZH008090040EUWV
Input:
100 – 240 V ~ 50 / 60 Hz 0.2 A
Output:
9 V DC 0.4 A
Protection
class:
II
Type of protection: