J-PRO-22 Alum Guide Rev 0021622 Page | 10
Install Suction Tubing from Pump to Solution Tank
Connect hard tubing from foot valve in Solution Tank to Inlet/ Suction side of metering pump
1.
Measure the tubing from the outside of the solution tank to ensure it will be 2-3” from the
bottom of the solution tank.
2.
Do not allow weight to sit at the bottom of the tank. Connect tubing to the foot valve and put
the ceramic weight on.
3.
Run the tubing up through the hole and connect to the Inlet/ Suction side of pump
Suction
Ceramic
Connector
Foot