Fleck 7000 Neutralizer Installation & Startup Guide
Page 6
www.cleanwaterstore.com
Rev 120215
Assembly and Installation Instructions
1.
By hand, unscrew the entire Fleck 7000 control valve from the top of the tank (if it was shipped
screwed on). If not already done, make sure the blue cap is on top of the distributor tube, or wrap
the top of distributor tube with electrical or duct tape. You do not want Calcite to go down the
distributor tube.
2.
Next, add Calcite or Calcite-blend media.
If you are using a blend of Calcite and Corosex, make sure
to read page 11 for more information on using and adding blends.
3.
Remove cap or tape from the top of distributor tube. Be careful not to pull up the distributor tube
when removing cap or tape.
4.
If possible at this point, fill tank completely with water. This will allow the neutralizer media to settle
and eliminate the need for purging air out of the tank later.
5.
Attach plastic top screen to the under-side of the Fleck 7000 control valve. It is a funnel-shaped
plastic screen that snaps on to the control valve and prevents resin from being backwashed out to
drain during the regeneration cycles.