Clean Water Systems 7500-REV4 Скачать руководство пользователя страница 12

7500-Rev4 Pro-Ox-AIR Filter Installation & Startup Guide 

12                                                  

www.cleanwaterstore.com

                                                                    rev 12821 

 

7

 

After the backwash, the system will automatically go into the fast rinse stage.   The control 
valve will return to service status (indicated by the up flowing meter on the left) after the 
backwash and rinse are complete. 

8

 

Repeat the Regeneration (backwash and rapid rinse cycle) step 3 to 4 more times until you 
see clear water through the drain line or your hose bib after the filter system. 

Congratulations, you are done setting up your new system! 

 

Advanced Programming Mode 

 

Skip this for most applications as your filter system has already been set to correct modes. 

1.

 

Plug the RevV4 in and immediately press in sequence 

MENU/CONFIRM, 

then press

 

BACK/REGEN 

button, then press the

 DOWN 

button to enter the Advanced Programming Mode.  

2.

 

Press 

UP

 or 

DOWN

 buttons or to select the menu item to be changed  

3.

 

Note: If valve locks while programming, unplug power supply and repeat step above. 

4.

 

Press 

MENU/CONFIRM 

to enter the main menu 

5.

 

Press the 

UP

 or 

DOWN

 buttons to highlight each option. 

6.

 

Press 

MENU/CONFIRM

 to

 

enter highlighted option.  

7.

 

Press the 

UP

 or 

DOWN

 buttons to adjust the value.  

8.

 

Press the 

MENU/CONFIRM 

to accept the changes. 

9.

 

Press 

BACK/REGEN 

button to advance to service status 

 

 

 

 

 

Содержание 7500-REV4

Страница 1: ... up VERY slowly during the initial backwash by opening inlet valve slowly to avoid pushing the media up into the control head Performing multiple backwashes at start up is an important step You should also not bring any other systems online i e softeners filters etc until the Pro Ox system is fully flushed Depending on the water quality this may take several backwashes and a week or two of normal ...

Страница 2: ...etal Piping Systems 5 How Your Pro Ox Iron Filter Works 6 Diagram of Typical Installation 6 Tank Assembly and Installation Instructions 7 Programming Your Valve 9 Set Time of Day 10 Set Date 10 Start the First Backwash 11 Advanced Programming Mode 12 Advanced Program Recommended Settings 13 Maintenance 14 Exploded Parts View 15 7500 Rev4 Water Filters Limited Warranty 17 ...

Страница 3: ...u find that that your tank does not sit level on the floor you can easily adjust it by holding the empty tank and tap it on a concrete or solid floor once or twice to level it Pro Ox Filter 0 75 cubic foot size 8 x 44 filter tank with distributor tube 9 lbs filter gravel 56 lbs Pro Ox media 10 lbs Turbidex media Pro Ox Filter 1 0 cubic foot size 9 x 48 filter tank with distributor tube 12 lbs filt...

Страница 4: ...e backwash and rinse cycle Best Practices for Piping Drain Installation 1 Make sure to connect the Inlet from your water source and outlet following arrows on control valve bypass 2 Make sure there is a working gate or ball valve before the system and also one after as well as a bypass valve 3 A hose bib which is a faucet to which you can attach a garden hose is strongly recommended after your fil...

Страница 5: ... grounded appliances downstream or potential galvanic activity in the plumbing system can no longer ground through the contiguous metal plumbing Some homes may have been built in accordance with building codes which encouraged the grounding of electrical appliances through the plumbing system Consequently the installation of a bypass consisting of the same material as the existing plumbing or a gr...

Страница 6: ...top of the tank and flows down through the media and up the distributor tube During backwash the flow of water is reversed and water flows down the distributor tube and up through the media lifting and expanding the Pro Ox media During the backwash the Pro Ox is cleaned by the action of the water flowing through it Diagram of Typical Installation ...

Страница 7: ...e 5 Add 1 cup of regular chlorine bleach and fill tank completely with water Allow media to soak for 1 hour but 24 hours or more is OK 6 Add a small amount of silicone grease to the inner O ring where the distribution tube goes 7 Next install the top screen by inserting upwards and rotating to lock in place This is a funnel shaped plastic screen that locks into the bottom side of control valve 8 L...

Страница 8: ...ubing to drain 12 If you are in earthquake zone strap your backwash filter tank to wall with metal strapping 13 Proceed to programming your 7500 Rev4 control valve timer and backwash frequency IMPORTANT you must program the time and then start a backwash and rinse The filter system must be backwashed and rinsed several times before using See following pages for instructions ...

Страница 9: ...ected time Extended Power Outage Indicator If power outage exceeds 3 days the time of day indicator _ will flash 12 12 The current time of day needs to be re set All other set parameters remain stored in memory The valve will resume to operate from the point of the power outage Lockout Function Keypad will lock after 5 minutes without use To access the parameter changes press and hold Up and Down ...

Страница 10: ...s DOWN button to select and scroll down to Set Date 3 Month Press the MENU CONFIRM button again to change time of day Month will flash and adjust to current Month date by using DOWN or UP buttons 4 Day Press the MENU CONFIRM button again to change Day date Day date will flash and adjust to current day date by using DOWN or UP buttons 5 Year Press the MENU CONFIRM button again to change Year date Y...

Страница 11: ...he Bypass Position 3 Press the BACK REGEN button once to enter the backwashing cycle 4 When the backwash icon is displayed slowly open the bypass to a quarter position to make the water flow into the tank and out the backwash drain line to drain 5 After several minutes open bypass valve completely 6 If possible verify that the backwash flow corresponds with the size of your system below You can ea...

Страница 12: ...m Advanced Programming Mode Skip this for most applications as your filter system has already been set to correct modes 1 Plug the RevV4 in and immediately press in sequence MENU CONFIRM then press BACK REGEN button then press the DOWN button to enter the Advanced Programming Mode 2 Press UP or DOWN buttons or to select the menu item to be changed 3 Note If valve locks while programming unplug pow...

Страница 13: ...Set Company Info CWS 831 462 8500 Set Hour Mode 12 HR Set Time of Day Current time of day Set Date Current date Set Program Type Interlock Set Regen Cycles No 4 Set Set Clear Data Close Set Regen Mode A 06 Set Service Days 4 Set Regen Time 2 00 AM Set Backwash Time 10 Minutes Set Air Draw Time 10 Minutes Set Fast Rinse Time 8 Minutes Signal Output Mode b 01 Set Service Alarm Disabled Review Regen ...

Страница 14: ...dia and replace with new media Once a year clean the nozzle and throat on the injector Turn off water pressure to your system and release any pressure by opening up a hose bib or faucet downstream of the filter system Remove the two bolts covering the injector Using small screwdriver remove the injector nozzle and throat and filter screen and clean with paperclip and rinse in vinegar to remove any...

Страница 15: ...7500 Rev4 Pro Ox AIR Filter Installation Startup Guide 15 www cleanwaterstore com rev 12821 Exploded Parts View ...

Страница 16: ...7500 Rev4 Pro Ox AIR Filter Installation Startup Guide 16 www cleanwaterstore com rev 12821 ...

Страница 17: ...ars Conditions 1 This warranty only covers water conditioners installed for residential use Water conditioners installed for commercial or industrial applications are guaranteed for one 1 year from the date of installation 2 Installation must be made in accordance with legal or local codes and manufacturer s recommendations 3 Failure must not result from exposure to weather rodents misuse alterati...

Отзывы: