![Clean Water Systems 7500-REV4 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/clean-water-systems/7500-rev4/7500-rev4_installation-manual_2620085012.webp)
7500-Rev4 Pro-Ox-AIR Filter Installation & Startup Guide
7
After the backwash, the system will automatically go into the fast rinse stage. The control
valve will return to service status (indicated by the up flowing meter on the left) after the
backwash and rinse are complete.
8
Repeat the Regeneration (backwash and rapid rinse cycle) step 3 to 4 more times until you
see clear water through the drain line or your hose bib after the filter system.
Congratulations, you are done setting up your new system!
Advanced Programming Mode
Skip this for most applications as your filter system has already been set to correct modes.
1.
Plug the RevV4 in and immediately press in sequence
MENU/CONFIRM,
then press
BACK/REGEN
button, then press the
DOWN
button to enter the Advanced Programming Mode.
2.
Press
UP
or
DOWN
buttons or to select the menu item to be changed
3.
Note: If valve locks while programming, unplug power supply and repeat step above.
4.
Press
MENU/CONFIRM
to enter the main menu
5.
Press the
UP
or
DOWN
buttons to highlight each option.
6.
Press
MENU/CONFIRM
to
enter highlighted option.
7.
Press the
UP
or
DOWN
buttons to adjust the value.
8.
Press the
MENU/CONFIRM
to accept the changes.
9.
Press
BACK/REGEN
button to advance to service status