![Clean Water Systems 5900e-AIR Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/clean-water-systems/5900e-air/5900e-air_installation-and-start-up-manual_2620079014.webp)
Air Charger Sulfur Filter 5900e-AIR Installation & Startup Guide
Page 14
www.cleanwaterstore.com
Rev 082616
5.
To Set the Number of Days between Air-Draw Cycles (d) Press the Set/Change Button
1) Set to 1 day, to regenerate the system with new air daily.
Example [ d - 01]
2) During this process, the valve will use a little bit of water to create suction in order to
regenerate the air, and will make some noise during this cycle. However, the valve will still
backwash on the days that you have programmed it to.
2) If Value Set to 0, Air-Draw is Turned Off, but an Air Cycle will still be Completed when a
Regeneration Cycle Occurs. If the Number of Days between Air-Draw Cycles is set to a Higher
Number of Days than the Number of Days between Regeneration Cycles, it will have no effect.
6. To exit menu press the Menu/Enter button
Note: If no buttons are pressed for 60 seconds or longer the menu will automatically be
exited.
Next you will need to set the Master Programming to be used as an Air Charger Sulfur Filter
5900e-AIR filter, continue on to the Master Programming to finish the programming
instructions.
Master Programming Mode:
Entering Master Programming Mode
-To enter Master Programming Mode press and hold both buttons for 5 seconds.
1. Regeneration Time (r)
Press the Menu/Enter Button. The next display viewed is the option setting for
Regeneration Time. It is identified by the letter ‘r’ in the left digit. Set the desired time
of day that a regeneration may occur, if required. We recommend setting the system to
backwash at 2 AM, or at any time that it is unlikely that any water will be used. The first
digit(s) indicates the Hour and the other digit indicates A.M. or P.M..
Example: 2 A.M. regeneration time - [ r 2A ] (factory setting)
3. Regeneration Cycle Step Programming (2)(3)(4)(5)
Step 1, the air release, is not programmable, and therefore will not be displayed for
programming. Each display is used to set the duration time in minutes for that specific
step in a regeneration cycle. A step # will turn on for the regeneration cycle step being
programmed. Regeneration steps are skipped by setting the display to 0 as shown
below:
Examples: Regeneration Cycle Step #2 - 10 minutes - [ 2 - 10 ]
Regeneration Cycle Step #3 - skipped - [ 3 - 0 ]
Set each step according to the values below, appropriate for an Air Charger Sulfur Filter
5900e-AIR filter: