background image

 

 

 

 

 
The LCD display shows the numeric values for temperature and relative humidity and the length of 
time remaining on the timer. It also displays the icons used to indicate other humidifier functions. 

LCD Display 

Display

 

 
 
 
 
 
 
 
 
 
 
 

19. Displays the temperature (

margin of about 2-5 degrees difference from the room temperature)

 

20. Timer 
21. Negative ions on/off indicator icon 
22. Emty water tank indicator icon 
23. Warm mist on/off icon 
24. Power on/off icon 
25. Shows values for both the desired relative humidity and the actual relative humidity 
26. Mist volume indicator (low, medium and high) 
 

 

 

The 

Clean Air Optima CA-605

 is equipped with a 

Permanent Reusable White Dust & Anti-

Microbial Filter

. It consists of an inner cylinder, an outer cover and a number of small plastic and 

ceramic balls. The plastic balls are embedded with nano-silver, an anti-microbial agent designed to 
purify the water and destroy microbes such as bacteria and mould. The ceramic balls function to 
soften the water by adhering to minerals that cause white dust. They also serve to remove any 
unpleasant odour from the water. The filter requires cleaning about once a month or 1,000 hours of 
use. See the 

Maintenance section

 of more information. 

OPERATING INSTRUCTIONS 

 

 

 
 

 

Содержание CA-605

Страница 1: ...1 Ultrasonic Humidifier with Ionizer CA 605 Instruction Manual ...

Страница 2: ... not operate the unit without water in the basin Do not insert foreign objects into the device Do not touch the transducer or the lower water basin when the unit is operating Do not scratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water Water or cleaning liquids may only be used on parts to be cleaned according to the cleaning and maintena...

Страница 3: ...ttom edge of the unit just below our logo Diagram air humidifier CA 605 1 Power Switches the humidifier on off 2 Ion Switches negative ions on off 3 Max Min Sets misting spray level to low medium or high 4 Heating Switches warm mist on off 5 Humidity Sets desired humidity level from 45 to 90 6 Timer Sets the timer to operate the humidifier from 1 to 12 hours 7 Display 8 Mist output jets 9 Water ta...

Страница 4: ...ual relative humidity 26 Mist volume indicator low medium and high The Clean Air Optima CA 605 is equipped with a Permanent Reusable White Dust Anti Microbial Filter It consists of an inner cylinder an outer cover and a number of small plastic and ceramic balls The plastic balls are embedded with nano silver an anti microbial agent designed to purify the water and destroy microbes such as bacteria...

Страница 5: ...o blink the word HUMID You can select the desired humidity level by pressing this button repeatedly until the required humidity level is displayed from 45 to 90 in increments of 5 Once you select your desired humidity level simply stop pressing the button and your humidity level will be set Wait another 5 seconds and the numeric value on the LCD display will switch to the current humidity level as...

Страница 6: ...er basin Remove the water tank Take a machine doesn t work small cup and remove some of the water from the machine s water basin Reinsert the water tank and make sure that it sits properly The volume of spray mist is too Too much mineral scale in the water Clean transducer low basin Water is too dirty or water was kept too Clean the water tank and refill long in the tank with clean water Abnormal ...

Страница 7: ... water if your mineral level is still too high 2 If you are using the machine on a daily basis clean the transducer water tank and basin once a week 3 When the water tank needs a refill empty the remaining water from the tank and fill it with fresh water 4 Clean the whole machine and make sure to keep all the parts completely dry when the machine is not in use How to clean the transducer 1 Place 5...

Страница 8: ...to 55 relative humidity During the winter months though relative humidity in the average home can drop to below 20 Low humidity can lead to a variety of conditions that cause ill health Dust particles bacteria viruses dust mite feces that are normally trapped by the moist nasal membrane lining in the nose can more easily get into the lungs when the air is dryer and thus reduce the body s natural d...

Страница 9: ...fill the tank Large capacity water tank 5L 1 32 US gallons easy refills with normal tap water Runs up to 7 nights or 60 ours without refilling low setting Save money No wicks or filters to replace Low power consumption Applicable for small and larger rooms up to 699 ft 65m 160m Benefits of proper humidification reduces discomfort tiredness sickness reduces susceptibility to colds reduces chapped l...

Страница 10: ...ded that the malfunction or damage to the device and or parts occurred under normal operating conditions What is covered All parts defective in material and workmanship For how long Two years from purchase date What we will do Repair or replace any defective parts Exclusions Regular replacement parts such as filter cartridges Other Conditions The provisions of this warranty are in lieu of any othe...

Отзывы: