background image

Repair or Warranty Contact

 

Clayton Associates, Inc. • 1650 Oak Street • Lakewood, New Jersey 08701 • P.+1-732-363-2100 F.+1-732-364-6084

WGP-0 

www.DustlessMadeSimple.com

 • 

[email protected]

 

Page 3

READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE

When using an electrical appliance, basic precautions should always be followed, including the following:
WARNING

To reduce the risk of fire, electric shock, or injury:

• 

Do not

 leave appliance when plugged in. Unplug from outlet when not in use and before servicing.

•  This unit is to be used only indoors and in a dry location.
•  Use only as described in this manual. Use only manufacturer’s recommended attachments.
• 

Do not

 use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, 

or dropped into water, return it to a service center.

•  Handle provided on power head is used only for removal of power head during maintenance.
•  Before separation of power head from tank, users must disengage draw latches on tank. 
• 

Do not

 pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. 

• 

Do not

 run appliance over cord. Keep cord away from heated surfaces.

• 

Do not

 unplug by pulling on cord. To unplug, grasp the plug, not the cord.

• 

Do not

 handle plug or appliance with wet hands.

• 

Do not

 put any object into openings. 

Do not

 use with any opening blocked; keep free of dust, lint, hair, and anything that may 

reduce air flow.

• 

Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.

• 

Turn off all controls before unplugging.

• 

Do not

 use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present.

•  Connect to a properly grounded outlet only. Refer to “EARTHING/GROUNDING INSTRUCTIONS” on page 3.
• 

Do not

 pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.

• 

Do not

 use without all filters in place.

• 

Do not

 allow to be used as a toy. Close attention necessary when used by or near children.

EARTHING/GROUNDING INSTRUCTIONS

This appliance must be earthed/grounded. If it should malfunction or breakdown, earthing/grounding provides a path of least resistance 

for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-earthing/grounding 

conductor and earthing/grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and earthed/grounded in 

accordance with all local codes and ordinances.

WARNING

 – Improper connection of the equipment-earthing/grounding conductor can result in a risk of electric shock. Check with a qualified 

electrician or service person if you are in doubt as to whether the outlet is properly earthed/grounded. Do not modify the plug provided with the 

appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Refer to Name Plate for electrical requirements.

• 

USA 120 V

This appliance has a earthing/grounding attachment plug that looks like the 

plug illustrated in Figure 1. Make sure that the appliance is connected to an 

outlet having the same configuration as the plug. No adapter should be used 

with this appliance.

• 

International 120 V

This appliance has an IEC 60309 120 V earthing/grounding attachment plug. 

Make sure that the appliance is connected to an outlet having the same 

configuration as the plug. No adapter should be used with this appliance.

• 

International 220 V – 240 V

This appliance has an IEC 60309 250 V earthing/grounding attachment plug. 

Make sure that the appliance is connected to an outlet having the same 

configuration as the plug. No adapter should be used with this appliance.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Figure 1:  Earthed/Grounded Outlet and Plug

GL_002

Grounded 

Outlet Box

Grounded Outlet

Grounding Pin

Содержание Warthog WGP Series

Страница 1: ...tand this manual before operating your air tool A HEPA Filter must be installed in this vacuum at all times If this vacuum is used to collect hazardous material appropriate personal protective equipment may be required Any alteration to this equipment by a third party will nullify its warranty WartHog WGP Power Head Electric Industrial HEPA Vacuum with Pneumatic Tool Sync Models WGP 107G 0 WGP 115...

Страница 2: ...ayton com Page 2 Important Safety Instructions 3 Applications Environments 4 What s In the Box 4 Specifications Requirements 4 Getting Started 5 Compressed Air Fittings 7 Pneumatic Tool Sync 8 Before Each Use 9 Bag Filter Change 10 Pre Filter Change 11 HEPA Filter Change 12 Illustrated Parts Breakdown 13 Limited Lifetime Warranty Terms And Conditions 18 EC Declaration of Conformity 19 ...

Страница 3: ...ning or smoking such as cigarettes matches or hot ashes Do not use without all filters in place Do not allow to be used as a toy Close attention necessary when used by or near children EARTHING GROUNDING INSTRUCTIONS This appliance must be earthed grounded If it should malfunction or breakdown earthing grounding provides a path of least resistance for electric current to reduce the risk of electri...

Страница 4: ...other components These instructions assume you have both a power head and an appropriate Clayton vacuum tank Refer to the instruction manual included with the vacuum tank for additional information PHYSICAL Weight TBD lbs TBD kg Dimensions Diameter x Height 17 5 x 12 in 44 5 x 30 5 cm Sound Level 67 dBA POWER CONSUMPTION Power Rating 2 hp Power Consumption 13 5 A 120 Vac TBD A 220 240 Vac Pressure...

Страница 5: ...he power head to verify that no parts are missing or damaged 4 Familiarize yourself with the power head 5 Power Head Vents NEVER BLOCK THE POWER HEAD VENTS NEVER WRAP THE POWER CORD AROUND THE POWER HEAD VENTS GETTING STARTED WGP 0_005 Compressed Air Coupler Air Out Compressed Air Coupler Air Out HEPA Wire Lock Hex Standoff HEPA Wire Lock Hex Standoff Power Switch WGP 0_006 Pneumatic Tool Sync Gau...

Страница 6: ...3 Install a new HEPA filter Holding the power head on its side screw the new HEPA filter onto the filter adapter Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head If it is not rotate it clockwise until fully seated Refer to the instructions included with the HEPA cable lock to install the cable lock 4 Attach the power head Position the power hea...

Страница 7: ...d Air Plug may be changed to another nominal 1 4 in 6 mm style if required Hold the brass bulkhead fitting with a 1 in 26 mm open end wrench Remove the compressed air plug with either a 9 16 in 14 mm deep socket or open end wrench Install a new compressed air plug Compressed Air Coupler Air Out The Vacuum is supplied with two 1 4 in 6 mm brass high flow compatible industrial interchange compressed...

Страница 8: ...ther end of the compressed air line to the Compressed Air Plug Air In on the vacuum head 2 Attach the compressed air tool Insert the compressed air line plug into a Compressed Air Coupler Air Out on the power head The vacuum may activate briefly once the airline has been connected Connect the compressed air line coupler to the tool s compressed air plug input 3 Test Pneumatic Tool Sync Toggle the ...

Страница 9: ... of the work hose assembly Insert the compressed air plug into a Compressed Air Coupler Air Out port on the power head The vacuum may activate briefly once the airline has been connected 4 Attach a tool optional Insert the tool s compressed air plug into the compressed air output hose coupler The vacuum may activate briefly once the tool has been connected 5 Plug the power head vacuum into an appr...

Страница 10: ...ning on the bag lift the bag out of the tank Dispose of the bag according to company policy 4 Install a new filter bag Unfold and fluff a new filter bag Push the inlet tube into the hole on the cardboard collar of the filter bag Grasp the sides of the cardboard collar and push it all the way onto the inlet tube Verify the bottom of the collar is past the opening on the underside of the inlet tube ...

Страница 11: ... the pre filter The pre filter is wrapped around the HEPA filter and secured with Velcro Find the seam and carefully peel the Velcro apart Dispose of the pre filter according to company policy 4 Install a new pre filter Unfold a new pre filter and remove the thin Velcro cover strip from the Velcro hooks Wrap the pre filter tightly around the HEPA filter Secure the pre filter by adhering the Velcro...

Страница 12: ...x and set aside Remove the HEPA filter from the box and remove it from the plastic bag 4 Remove the old HEPA filter Holding the power head on its side cut the HEPA cable lock and remove it Unscrew the HEPA filter from the filter adapter Dispose of the HEPA filter according to company policy 5 Install a new HEPA Filter Holding the power head on its side screw the new HEPA filter onto the threaded f...

Страница 13: ...14 ga 3 Position 7 900 M14S Molex Socket Terminal 14 ga 8 900 SW SPDT 01 Switch Rocker Rect 20A 120V SPDT On Off On Black 9 918 04BH Bulkhead Adapter Brass 1 4in 10 924 04CV Check Valve 1 4 MNPT 11 930 027 Handle Carry Flex Rubber 12 940 011 Fitting Coupler 1 4in Hiflow x 1 4 MNPT 13 940 016 Fitting Plug 1 4in Hiflow x 1 4in MNPT 14 FE103212 HZSM Z Hex Standoff 10 32 MF x 3 4 in SS 15 NE10320608 H...

Страница 14: ...Switch Pneumatic Relay 100PSI 15A 120V 4 922 T 25GN 1 4 in OD Nylon Tubing Green 5 922 T 50BK Tubing 1 2 OD High Temp per ft 6 924 04FC 01 Alpha Flow Control Valve 7 925 P24R160 01 Gauge Pressure 1 5in 0 160 PSI Panel Mount 8 927 04FA 02 Female Adapt 1 4 PC x 1 8 FNPT 9 927 04L 02 PC Elbow 1 8 MNPT x 1 4 Tube 10 927 04L 02F FTG Elbow 1 8 FNPT To 1 4 PC 11 927 04T Tee 1 4 PC 12 927 08L 04 FTG Elbow...

Страница 15: ...trated Parts Breakdown 603 WGP 0 Sheet 3 of 5 WGP 0_013 1 2 3 4 5 Seq Item No Description 1 911 803 1 Handle Cap Sound Control Foam 2 911 803 2 Exhaust Baffle Sound Control Foam 3 911 803 3 Enclosure Top Sound Control Foam 4 911 803 4 Base Ring Sound Control Foam 5 911 803 6 Enclosure Foam 1 Sound Control 5 911 803 7 Enclosure Foam 2 Sound Control 5 911 803 8 Enclosure Foam 3 Sound Control ...

Страница 16: ... Head Base 16in SS Black 5 911 011 Gasket Filter Adapter 6 911 Q6600 220T Conical Motor Gasket Silica Gel 7 FE103208 HZSM B Hex Standoff 10 32 MF x 1 2 SS With Bore 8 NE10320615 HNSZ Nut 10 32 Nylon Lock SS High 9 NE16201420 HNSZ Nut 1 4 20 Hex Lock SS 10 SE162005 PPSM Z Screw 1 4 20 x 5 16 PH SS 11 SE162064 HHSM Z Screw 1 4 20 x 4in SS Hex 12 600 WF 1364F Washer Fiber 13 64 ID x 3 8OD 13 900 WH00...

Страница 17: ...Illustrated Parts Breakdown 603 WGP 0 Sheet 5 of 5 Seq Item No Description 1 600 Q6600 220T Motor Bypass 120V 13 5A 2HP 120CFM 2 605 310C HH Vac Head Motor Collar SS 3 911 04G08 Grommet 7 32 ID 1 2 OD 4 911 803 5 Motor Plate Sound Control Foam 5 SE101212 PPSS Z Screw Sheet Metal 10 X 750 Phillips SS 6 WE133203 RFS Z Washer 203ID X 500OD 047H Round Stainless Steel WGP 0_011 4 1 5 2 6 3 ...

Страница 18: ...selected service location and repair the product at no charge Clayton personnel will determine the best way to repair the product Past 90 days Clayton will provide parts to the customer s site at no charge or the customer may ship the product to a Clayton selected service location at customer s expense and Clayton will repair the product at no charge and provide return shipping Repair Outside the ...

Страница 19: ...ctured in compliance with the essential requirements and other relevant provisions of the following applicable directives Machinery Directive 2006 42 EC The Electromagnetic Compatibility Directive 2004 108 EC Compliance has been obtained by application of the following standards EN ISO 12100 2010 11 EN 60335 1 2012 A13 excluding 25 6 EN 60335 2 69 2012 specifically Annex AA Requirements for vacuum...

Страница 20: ...X XXXX 0 WGP XXXX 0 WTX XXXX 0 WTP XXXX 0 WGX XXXX 1 WGP XXXX 1 WTX XXXX 1 WTP XXXX 1 Tank Models 115G 115T 205G 205T 215G 215T With serial numbers ranging from WH0000001 through WH9999999 Were tested to verify the integrity of the HEPA filter and the assembled machine Test Procedure The test was performed using an aerosol generator and a photometer The system was challenged with 18 microliters mᶟ...

Страница 21: ...THIS PAGE IS INTENTIONALLY BLANK ...

Страница 22: ...or Warranty Contact Clayton Associates Inc 1650 Oak Street Lakewood New Jersey 08701 P 1 732 363 2100 F 1 732 364 6084 www DustlessMadeSimple com Sales JClayton com Clayton products are proudly made in the USA ...

Отзывы: