LED
Behavior Indication
Power
Green
Solid
Active - wakeup signal active
Green
1 Flash
Standby - wakeup signal active
Charge IN or OUT
Green
Solid
Charging has finished - battery full
Green
Flash 1Hz
Constant voltage - (Lead: >80%) - (Lithium: >95%)
Green
Flash 4Hz
Constant current - (Lead: <80%) - (Lithium: <95%)
Charge IN & OUT
Red
1 Flash
Short circuit - restart to recover
Red
2 Flash
Temperature too high - revocers automatically
Red
3 Flash
All Other failures
Jumpstart
Green
Solid
Jumpstart in final minut - Start the vehicle.
Green
Flash 4 Hz Jumpstart in progress - do not start the vehicle yet
Red
Flash
Jumpstart not able to run.
Data
Green
Solid
CAN active - device controlled
Green
Flash 1Hz
CAN active - unknown device
IN/OUT 12V
Green
Solid
12V functionality active
IN/OUT 24V
Green
Solid
24V functionality active
IN/OUT 12V & 24V
Green
Solid
Automatically selection is in process
IN/OUT 12V / 24V
Red
Flashing
Voltage is out of range.
The LED indications all have same individual behaviour:
LED Codes
4
Standards and approvals
Low Voltage Directive 2014/35/EU
EN62368-1:2014
EMC 2014/30/EU
EN61000-6-2:2005, EN61000-6-3:2007 / A1:2011
EN50498:2010 (UNECE Regulation 10)
E13 10R-05 14880 (E-mark)
RoHs Directive 2011/55/EU
EN50581:2012