Switching on the projector - Fig. 8

Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:

                                         Model                                      Firmware                             xxx (Fixture ID)                      System errors

                                                         HEPIKOS                                Version X.X.X                      Dmx Address xxx                 E: .........................

                                                                                                         Date - Hour                                                                        W: .........................

On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control
panel (Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two
conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address
(if set). 

During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the

F

key will be cancelled.

CONTROL PANEL

8

Connecting to the control signal line (DMX) - Fig. 7
Use  a  cable  conforming  to  specifications  EIA  RS-485:  2-pole  twisted,  shielded,  120Ohm  characteristic  impedance,  22-24  AWG,  low  capacity.  Do  not  use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 5-pin male/female
connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.
IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the
shield braid and to pin 1 of the connectors.

Connecting to the mains supply - Fig. 6

 

 

 

 

 

 

 

 

SIGNAL

SCREEN

DMX 512

5 PIN

1

2

3

4

5

SIGNAL

Mains

6

7

Continue  

Содержание HEPIKOS

Страница 1: ...ich Claypaky range has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements INDEX Page Contents 2 Safety information 3 Unpacking and preparation 4 Installation and start up 5 Control panel 7 Maintenance 15 Technical information 16 Cause and solution of problems ENGLISH HEPIKOS C61397 ...

Страница 2: ...uffindbar www claypaky com Ref FIS00H Safety Information Supersharpy Mythos Hepikos INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS00H Safety Information Supersharpy Mythos Hepikos CONSIGNES DE SÉCURITÉ ...

Страница 3: ...ixture 1 90 9 0 9 0 9 0 ETHERNET THRU IN DMX PINS 1 SCREEN 2 SIG NAL 3 SIG NAL MAIN S 115 230V 50 60Hz LOCKED UNLOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 LOCKED UNLOCKED 4 5 4 5 45 4 5 45 ...

Страница 4: ... Installing the projector Fig 4 The projector can be installed on the floor resting on special rubber feet on a truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the projector and then connected to the fixing point at ...

Страница 5: ... any key having been pressed the display automatically returns to rest status It should be noted than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled CONTROL PANEL 8 Connecting to the control signal line DMX Fig 7 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 ...

Страница 6: ... activate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations Inf...

Страница 7: ...nd releasing Pan and Tilt movements Refer to the instructions in the UNPACKING AND PREPARATION section Opening the head covers Fig 10 Closing the head covers Fig 11 2 4 1 1 4 Turn 1 1 4 Turn 3 2 10 11 MAINTENANCE Continue ...

Страница 8: ... glass to remove the dirt from the reflectors from the lenses and filters It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction using lubricants specifically supplied by Claypaky General visual check of th...

Страница 9: ...9 HEPIKOS 1 4 3 2 13 Cleaning of the filters Fig 13 Continue ...

Страница 10: ...10 HEPIKOS 2 1 4 Turn 1 4 1 4 Turn 3 2 3 1 5 4 Upper Side Lower Side 14 Extraction of the effect modules Preliminary operations Fig 14 ...

Страница 11: ... the effect modules Fig 15 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 14 15 and 16 in reverse order Continue ...

Страница 12: ...on of the effect modules Fig 16 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 14 15 and 16 in reverse order ...

Страница 13: ...d in alcohol and dry it with a clean dry cloth CAUTION Fast lamp ON OFF cycles for example 10 minutes ON 10 minutes OFF will reduce the lamp life Lamp regulation Fig 18 To centre the lamp turn the 2 adjusting screws as shown in the figure IMPORTANT Pay attention to the Dimmer blade when you open the lamp department you can bent it if it is on the wrong position please move it in the right position...

Страница 14: ...PIKOS Battery removal Fig 19 This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 1 2 3 4 6 5 5 5 19 ...

Страница 15: ...Web Server OPTICS Large 185mm diameter PC lens 5 40 electronic zoom EFFECTS SECTION Rotating Prism 1 x 4 facet prism indexable on 540 clockwise and counter clockwise rotation at variable speed Variable Frost 0 100 linear Color system CMY with linear insertion discs 2x Color wheels 8 colors each Iris 16 bit multiple macros random pulsing Dimmer 16 bit electronic and linear 2 dimmer curves Stop Stro...

Страница 16: ...BLE CAUSES CHECKS AND REMEDIES No mains supply Lamp exhausted or defective Signal transmission cable faulty or disconnected Incorrect addressing Fault in the electronic circuits Lenses or reflector broken Dust or grease deposited Check the power supply voltage Replace the lamp See instructions Replace the cables Check addresses see instructions Call an authorised technician Call an authorised tech...