background image

 
 

Axcor Profile 400 / Axcor Profile 400 HC – User Menu 

 

Axcor Profile 400 / Axcor Profile 400 HC 

User Menu

 

07/2020

 

USER MENU GUIDE 

 

SET UP MENU 

 

Setup - DMX ADDRESS 

It lets you select the address (DMX Address) for the control 
signal.  A  DMX  address  between  001  and  512  can  be 
selected. 

NOTE:  Without  the  input  signal,  the  displayed  DMX 
Address blinks. 
 

Permette  di  selezionare  l'indirizzo  (DMX  Address)  per  il 
segnale  di  controllo,  è  possibile  selezionare  un  indirizzo 
DMX compreso tra 001 e 512. 

NOTA:  Senza  il  segnale  DMX  in  ingresso  l’indirizzo 
DMX sul display lampeggia. 

Setup - ETHERNET INTERFACE 

It  lets  you  set  Ethernet  settings  to  be  assigned  to  the 
projector as indicated below: 
 
Custom IP Address 

 

It lets you to set the Internet Protocol Address according to 
the control unit used. 
 
Custom IP Mask 

 

It lets you to set the Subnet Mask of the IP address. 

Permette  di  impostare  le  impostazioni  Ethernet  da 
assegnare al proiettore qui di seguito indicate: 
 
Custom IP Address 
Permette  di  impostare  l’indirizzo  IP  in  base  alla  centralina 
di controllo utilizzata  
 
Custom IP Mask 

 

Permette di selezionare la Subnet Mask dell’indirizzo IP. 

Setup - UNIVERSE 

It  lets  you  set  the  “DMX  Universe”  to  be  assigned  to  a 
series of projectors with values between 000 and 255. 
A single DMX512 frame of 512 channels is referred to as a 
Universe

  

Permette  di  impostare  l’universo  DMX  da  assegnare  ad 
una serie di proiettori, valori compresi tra 000 e 255. 
Una  linea  DMX512  da  512  canali  fa  riferimento  ad  un 
singolo universo.

 

Setup – START CHANNEL 

It  lets  you  select  the  address  (Art-Net)  for  the  control 
signal.  An  Art-Net  address  between  001  and  512  can  be 
selected. 

Permette  di  selezionare  l'indirizzo  (Art-Net)  per  il  segnale 
di  controllo,  è  possibile  selezionare  un  indirizzo  Art-Net 
compreso tra 001 e 512. 

Setup – ETHERNET TO DMX 

It lets you enable/disable the transmission of the Ethernet 
protocol by DMX signal to all the connected projectors. 
 

 

NO: DMX transmission disabled. 

 

YES: DMX transmission enabled. 

 

Permette di abilitare/disabilitare la trasmissione del 
protocollo Ethernet tramite segnale DMX a tutti i proiettori 
connessi. 

 

NO: Trasmissione DMX disabilitata. 

 

YES: Trasmissione DMX abilitata. 

 

 
 

 

Содержание Axcor Profile 400

Страница 1: ...Main Menu Level 1 Level 2 Level 3 Choices Values SET UP DMX Address 001 512 Ethernet Interface Custom IP Address IP address byte 1 000 255 IP address byte 2 000 255 IP address byte 3 000 255 IP address byte 4 000 255 Custom IP Mask IP mask byte 1 000 255 IP mask byte 2 000 255 IP mask byte 3 000 255 IP mask byte 4 000 255 Universe 000 255 Start Channel 001 512 Ethernet to DMX No Yes ...

Страница 2: ... 180 degrees 270 degrees Tilt Home Def Pos 0 12 5 25 50 75 87 5 100 Color Color Mixing RGB CMY Fix Wheel Shortcut On Off CMY Speed Normal Fast Dimmer Curve Dimmer Curve 1 Dimmer Curve 2 Dimmer Curve 3 Dimmer Curve 4 Display On Off Fan Mode Auto SLN Theatre Constant Setting Default Preset Reset To Default Go Back Are you sure Yes No User Preset 1 Load preset 1 Save to preset 1 Are you sure Yes No U...

Страница 3: ...rs Read Reset System Version Disp Fw rev Net Fw rev Ctr1 XY Fw rev Ctr2 Motor Fw rev Ctr3 Motor Fw rev Ctr4 Motor Fw rev DMX Monitor Channels Bit Fans Monitor Base Fan Led Fan Network parameters IP Address IP Mask MAC Address UID UID xxxxxxxxx MANUAL CONTROL Reset Yes No Channel Bit Value TEST Pan Tilt Colour Beam Gobo Shutter All ADVANCED Access Code 1234 Upload Firmware Transfer Are you sure Yes...

Страница 4: ...tare l indirizzo IP in base alla centralina di controllo utilizzata Custom IP Mask Permette di selezionare la Subnet Mask dell indirizzo IP Setup UNIVERSE It lets you set the DMX Universe to be assigned to a series of projectors with values between 000 and 255 A single DMX512 frame of 512 channels is referred to as a Universe Permette di impostare l universo DMX da assegnare ad una serie di proiet...

Страница 5: ... input signal selecting one from the 7 available positions 0 12 5 25 50 75 87 5 100 Invert Pan Permette di abilitare ON l inversione del movimento Pan Selezionare OFF per non abilitare o disabilitare questa opzione Invert Tilt Permette di abilitare ON l inversione del movimento Tilt Selezionare OFF per non abilitare o disabilitare questa opzione Swap Pan Tilt Permette di abilitare ON l inversione ...

Страница 6: ...l verso che richiede lo spostamento meccanico minore Selezionare OFF per non abilitare o disabilitare questa opzione Option CMY SPEED Lets you select two different CMY movement speed Normal Fast Permette di selezionare una delle due differenti velocità di movimento dei filtri CMY Normal Fast Option DIMMER CURVE Lets you select four different Dimmer curves Dimmer curve 1 Dimmer curve 2 Dimmer curve...

Страница 7: ...onano sempre in maniera constante e l uscita di luce rimane ridotta senza variazioni Constant Le ventole funzionano sempre al massimo regime Option SETTING Used to save 3 different settings of the items in the option menu and relevant submenus Default preset User preset 1 User preset 2 User Preset 3 Load preset X is used to recall a previously stored configuration Save to preset X is used to save ...

Страница 8: ...LED on from construction to date Partial counter It counts the number of LED partial working hours from the last reset to date Press OK to reset the partial counter A confirmation message appears on the display Select Reset to confirm or Go Back to undo the operation Permette di visualizzare le ore di funzionamento totali e parziali dei LED Total counter Conta il numero di ore di funzionamento del...

Страница 9: ...ion UID Shows the exclusive address of the fixture to use communicate via RDM Mostra l indirizzo esclusivo del dispositivo da utilizzare per comunicare via RDM MANUAL CONTROL Manual Control RESET It lets you reset the projector from the projector control panel Permette di eseguire il reset del proiettore dal pannello comandi del proiettore stesso Manual Control CHANNEL It lets you set the channel ...

Страница 10: ...a group of fixtures Permette di eseguire tramite pannello comandi delle piccole regolazioni elettroniche degli effetti in modo tale da ottenere una migliore uniformità tra i proiettori Advanced MENU LOCKING It allows you to assign a password to lock the access to the ADVANCED menu to avoid any wrong setting or operation by people there are not from the technical staff The default Unlock Code is 12...

Отзывы: