OPERATORS MANUAL - 4M TRAILED
20
CLAYDON TRAILED 4 METRE
By pressing the Tramline/marker/lift inhibit operation key (2) in figure 11 will advance the drill
through to the third page phase of the tramline/marker/lift inhibit system and the message Count
Marker Sequence Inhibited message will be displayed for 2 seconds every 5 seconds,
(1) in Figure 12. This setting prevents the marker or tramline sequence moving on when the drill is
lifted and lowered, useful when drilling headlands etc. key (3) cancels the function and returns the
drill to normal operation.
Figure 13 displayed the Rate screen sub menu for seed and fertiliser, the corresponding buttons
and their functions can be seen in Figure 14.
Press the Enter key to toggle between seed and fertilizer, to adjust the target rate use the
number pad and press enter to store the setting.
Figure 12 – Count/Marker sequence Inhibited screen
Figure 13 – Rate screen Indications
1. Drill Lift inhibit message
2. Tramline/marker/lift inhibit
operation
3. Cancel
1. Time
2. Area cut out status (√ = In
work, X = Out of work)
3. Seed rate set
4. Fertiliser rate set
5. Seed rate applied (current)
6. Fertiliser rate applied (current)
7. Max drilling speed
Rate Screen